FCC ID 2AYGR-3042

Evoke Closed Loop Stimulator

by SALUDA MEDICAL PTY LIMITED

Grantee Code: 2AYGR   Product Code: 3042
Latest application date: 2022-05-23

FCC ID Device Details

FCC ID2AYGR-3042
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AYGR
Product Code3042
Applicant BusinessSALUDA MEDICAL PTY LIMITED 🇦🇺
Related Domains saludamedical.com
Equipment ClassEvoke Closed Loop Stimulator
Test FirmBureau Veritas CPS(H.K.) Ltd., Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
402-405 MHzOriginal Equipment2022-05-23

Exhibits

DocumentTypeAvailableFile
Users Manual revUsers Manual2022-11-19PDF 3.7 MB
External photosExternal Photos2022-11-19PDF 455.3 KB
Label Sample & Label Location revID Label/Location Info2022-05-23PDF 505.2 KB
Test setup photosTest Setup Photos2022-11-19PDF 205.3 KB
Test report (Part 95I) rev3Test Report2022-05-23PDF 937.6 KB
Confidentiality Request - One Way (Saluda) -NDACover Letter(s)2022-05-23PDF 134.2 KB
Confidentiality request (Long term & Short term)Cover Letter(s)2022-05-23PDF 315.4 KB
Cover Letter (Agent Authorization)Cover Letter(s)2022-05-23PDF 455.5 KB
RF Exposure Info (MPE) rev3RF Exposure Info2022-05-23PDF 170.9 KB
Internal Photos Metadata onlyInternal PhotosPDF 382 KB
Block diagram Metadata onlyBlock DiagramPDF 1.5 MB
Schematics Metadata onlySchematicsPDF 2.3 MB
Operational Description Metadata onlyOperational DescriptionPDF 335.9 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 250.1 KB
Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 252.8 KB

Application Information

Application IDDl5vjHyRAhPDyB4MAY2Zfg==
Final Action Date2022-05-23
Application PurposeOriginal Equipment
Applicant FRN0030295968
Model3042
Frequency Range402-405 MHz
Equipment ClassTNT - Licensed Non-Broadcast Transmitter Worn on Body
Device DescriptionEvoke Closed Loop Stimulator
Responsible PartyPeter Aigner, Peter.Aigner@saludamedical.com , +618405 8700
AgentAndrea Andrea Andrea, Bureau Veritas CPS (H.K.) Ltd., Taoyuan Branch, andrea.hsia@bureauveritas.com , 886-3-3183232
Test FirmEric Lin, Bureau Veritas CPS(H.K.) Ltd., Taoyuan Branch, eric-wp.lin@tw.bureauveritas.com , +886-3-2641570
TCB Emailcertification@nacsemc.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityYes
Short-Term Confidentiality Date11/19/2022
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is maximum EIRP.

Applications

Application IDDatePurpose
Dl5vjHyRAhPDyB4MAY2Zfg==2022-05-23Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
402-405 MHz0.00000047.9510000000ppm240KF1D95IIT

Grants

TCB Grant - Application Dl5vjHyRAhPDyB4MAY2Zfg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  North American EMC Certification Services Inc
24889 Ferguson Ave
Maple Ridge, BC,
Canada
Date of Grant: 05/23/2022

Application Dated: 05/23/2022
SALUDA MEDICAL PTY LIMITED
Saluda Medical
Ground Floor, 407 Pacific Hwy
Artarmon, NSW, 2064
Australia
 
Attention: Peter Aigner

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYGR-3042
Name of Grantee:  SALUDA MEDICAL PTY LIMITED
Equipment Class: Licensed Non-Broadcast Transmitter Worn on Body
Notes: Evoke Closed Loop Stimulator
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
IT 95I 402.0  -  405.0 4E-7 7.951  PM 240KF1D

Power listed is maximum EIRP.

IT: Implanted Transmitter

EAS Grant - Application Dl5vjHyRAhPDyB4MAY2Zfg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

SALUDA MEDICAL PTY LIMITED
Saluda Medical Ground Floor, 407 Pacific Hwy
Artarmon, NSW, 2064
Australia
  Date of Grant: 05/23/2022

Application Dated: 05/23/2022
 
Attention: Peter Aigner

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYGR-3042
Name of Grantee:  SALUDA MEDICAL PTY LIMITED
Equipment Class: Licensed Non-Broadcast Transmitter Worn on Body
Notes: Evoke Closed Loop Stimulator
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
IT 95I 402.0  -  405.0 4E-7 7.951  PM 240KF1D

Power listed is maximum EIRP.


IT: Implanted Transmitter

Mail To: