FCC ID 2AYGT-2S-00

Thermal Imaging Monocular

by IRay Technology Co., Ltd.

Grantee Code: 2AYGT   Product Code: 2S00
Latest application date: 2023-10-13

FCC ID Device Details

FCC ID2AYGT-2S-00
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AYGT
Product Code2S00
Applicant BusinessIRay Technology Co., Ltd. 🇨🇳
Related Domains iraytek.com
Equipment ClassThermal Imaging Monocular
Test FirmTUV SUD Cert & Testing (China) Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2023-10-13

Exhibits

DocumentTypeAvailableFile
ManualUsers Manual2024-04-10PDF 1.2 MB
Internal PhotosInternal Photos2024-04-10PDF 4.5 MB
External PhotosExternal Photos2024-04-10PDF 1.5 MB
LabelID Label/Location Info2023-10-13PDF 146.8 KB
Test Setup PhotosTest Setup Photos2024-04-10PDF 428.4 KB
Test ReportTest Report2023-10-13PDF 5.1 MB
Attestation Statements US agent for service of processAttestation Statements2023-10-13PDF 155.9 KB
Attestation of Covered EquipmentAttestation Statements2023-10-13PDF 146.2 KB
Models Difference LetterAttestation Statements2023-10-13PDF 228.4 KB
Agency LetterCover Letter(s)2023-10-13PDF 27.2 KB
Antenna InformationCover Letter(s)2023-10-13PDF 264.9 KB
Confidentiality LetterCover Letter(s)2023-10-13PDF 77.9 KB
RF Exposure ReportRF Exposure Info2023-10-13PDF 4.3 MB
Block Diagram Metadata onlyBlock DiagramPDF 142.4 KB
Schematics Metadata onlySchematicsPDF 1,005.7 KB
Operational Description Metadata onlyOperational DescriptionPDF 92.2 KB
Partlist Metadata onlyParts List/Tune Up InfoPDF 155.7 KB

Application Information

Application ID5XXwd10pxC89gSdjs/5kHA==
Final Action Date2023-10-13
Application PurposeOriginal Equipment
Applicant FRN0030296552
Model2S-00
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionThermal Imaging Monocular
Responsible PartyPeng Zhang, pzhang@iraytek.com , 086-0535-3410600
Test FirmHarry Zhou, TUV SUD Cert & Testing (China) Co., Ltd., harry.zhou@tuv-sud.cn , 86 755 3332 3281
TCB Emailandy.zhang@tuvsud.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date04/10/2024
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is conducted. SAR compliance for body worn operating configurations must be restricted to belt-clips and holsters described in this filing and which contain no metallic component in the assembly. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. The highest reported SAR for head and body-worn accessory are 0.01 W/kg and 0.03 W/kg, respectively.

Applications

Application IDDatePurpose
5XXwd10pxC89gSdjs/5kHA==2023-10-13Original Equipment

Equipment Authorization

FrequencyOutputRules
2412-2462 MHz0.060000015C

Grants

TCB Grant - Application 5XXwd10pxC89gSdjs/5kHA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  TUV SUD America Inc.
401 Edgewater Place Suite #500
Wakefield, MA 01880
Date of Grant: 10/13/2023

Application Dated: 10/13/2023
IRay Technology Co., Ltd.
11GUIYANG STREET, YANTAI ECONOMY AND TECHNOLOGY
DEVELOPMENT DISTRICT, YANTAI SHANDONG P.R.CHINA
YANTAI,
China
 
Attention: Peng Zhang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYGT-2S-00
Name of Grantee:  IRay Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Thermal Imaging Monocular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.06  

Power listed is conducted. SAR compliance for body worn operating configurations must be restricted to belt-clips and holsters described in this filing and which contain no metallic component in the assembly. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. The highest reported SAR for head and body-worn accessory are 0.01 W/kg and 0.03 W/kg, respectively.

EAS Grant - Application 5XXwd10pxC89gSdjs/5kHA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

IRay Technology Co., Ltd.
11GUIYANG STREET, YANTAI ECONOMY AND TECHNOLOGY DEVELOPMENT DISTRICT, YANTAI SHANDONG P.R.CHINA
YANTAI,
China
  Date of Grant: 10/13/2023

Application Dated: 10/13/2023
 
Attention: Peng Zhang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYGT-2S-00
Name of Grantee:  IRay Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Thermal Imaging Monocular
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.06  

Power listed is conducted. SAR compliance for body worn operating configurations must be restricted to belt-clips and holsters described in this filing and which contain no metallic component in the assembly. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. The highest reported SAR for head and body-worn accessory are 0.01 W/kg and 0.03 W/kg, respectively.