FCC ID 2AYGT-M200A

M200 Series Handheld Thermal Camera

by IRay Technology Co., Ltd.

Grantee Code: 2AYGT   Product Code: M200A
Latest application date: 2022-01-07

FCC ID Device Details

FCC ID2AYGT-M200A
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AYGT
Product CodeM200A
Applicant BusinessIRay Technology Co., Ltd. 🇨🇳
Related Domains iraytek.com
Equipment ClassM200 Series Handheld Thermal Camera
Test FirmCCIC Southern Testing Co., Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2022-01-07

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2022-01-07PDF 558.7 KB
Internal PhotosInternal Photos2022-01-07PDF 1.9 MB
Internal photosInternal Photos2022-01-07PDF 1.9 MB
External PhotosExternal Photos2022-01-07PDF 780.8 KB
External photosExternal Photos2022-01-07PDF 780.8 KB
Label and LocationID Label/Location Info2022-01-07PDF 234.3 KB
Label_LocationID Label/Location Info2022-01-07PDF 234.3 KB
Test setup photoTest Setup Photos2022-01-07PDF 375.6 KB
Test setup photoTest Setup Photos2022-01-07PDF 341.4 KB
Test ReportTest Report2022-01-07PDF 3.7 MB
Test ReportTest Report2022-01-07PDF 935.5 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2022-01-07PDF 32 KB
FCC_Short Long Term Confidentiality RequestCover Letter(s)2022-01-07PDF 32 KB
Letter of AuthorizationCover Letter(s)2022-01-07PDF 119.2 KB
BLOCK Metadata onlyBlock DiagramPDF 129.2 KB
BlockDiagram Metadata onlyBlock DiagramPDF 129.2 KB
SCH Metadata onlySchematicsPDF 805.5 KB
Operation Description Metadata onlyOperational DescriptionPDF 379.4 KB

Application Information

Application IDsE77r4DQb2z3qnDmo+QiDg==
Final Action Date2022-01-07
Application PurposeOriginal Equipment
Applicant FRN0030296552
ModelM200A
Equipment ClassJBP - Part 15 Class B Computing Device Peripheral
Device DescriptionM200 Series Handheld Thermal Camera
Responsible PartyPeng Zhang, pzhang@iraytek.com , 18562243217
Technical ContactIRay Techonlogy Co.,Ltd., pzhang@iraytek.com
Test FirmZhang Shuangwen, CCIC Southern Testing Co., Ltd, zhangsw@ccic-set.com , 86-0755-86131239
TCB Emailcertification@micomlabs.com
TCB ScopeA1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
sE77r4DQb2z3qnDmo+QiDg==2022-01-07Original Equipment
PNkOAxgE5XLqlOZYz2nUJA==2022-01-07Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
15BCC
2412-2462 MHz0.055700015CCC

Grants

TCB Grant - Application sE77r4DQb2z3qnDmo+QiDg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 01/07/2022

Application Dated: 01/07/2022
IRay Technology Co., Ltd.
11GUIYANG STREET, YANTAI ECONOMY AND TECHNOLOGY
DEVELOPMENT DISTRICT, YANTAI SHANDONG P.R.CHINA
YANTAI,
China
 
Attention: Peng Zhang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYGT-M200A
Name of Grantee:  IRay Technology Co., Ltd.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: M200 Series Handheld Thermal Camera
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application sE77r4DQb2z3qnDmo+QiDg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

IRay Technology Co., Ltd.
11GUIYANG STREET, YANTAI ECONOMY AND TECHNOLOGY DEVELOPMENT DISTRICT, YANTAI SHANDONG P.R.CHINA
YANTAI,
China
  Date of Grant: 01/07/2022

Application Dated: 01/07/2022
 
Attention: Peng Zhang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYGT-M200A
Name of Grantee:  IRay Technology Co., Ltd.
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: M200 Series Handheld Thermal Camera
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application PNkOAxgE5XLqlOZYz2nUJA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 01/07/2022

Application Dated: 01/07/2022
IRay Technology Co., Ltd.
11GUIYANG STREET, YANTAI ECONOMY AND TECHNOLOGY
DEVELOPMENT DISTRICT, YANTAI SHANDONG P.R.CHINA
YANTAI,
China
 
Attention: Peng Zhang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYGT-M200A
Name of Grantee:  IRay Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: M200 Series Handheld Thermal Camera
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0557  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory use condition is 0.17W/kg.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application PNkOAxgE5XLqlOZYz2nUJA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

IRay Technology Co., Ltd.
11GUIYANG STREET, YANTAI ECONOMY AND TECHNOLOGY DEVELOPMENT DISTRICT, YANTAI SHANDONG P.R.CHINA
YANTAI,
China
  Date of Grant: 01/07/2022

Application Dated: 01/07/2022
 
Attention: Peng Zhang

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYGT-M200A
Name of Grantee:  IRay Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: M200 Series Handheld Thermal Camera
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2412.0  -  2462.0 0.0557  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 cm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory use condition is 0.17W/kg.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: