FCC ID 2AYHD-CMF04

Media Measurement Gateway

by Hyphametrics,Inc.

Grantee Code: 2AYHD   Product Code: CMF04
Latest application date: 2026-08-06

FCC ID Device Details

FCC ID2AYHD-CMF04
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AYHD
Product CodeCMF04
Applicant BusinessHyphametrics,Inc. 🇺🇸
Related Domains hyphametrics.com
Equipment ClassMedia Measurement Gateway
Test FirmShenzhen LCS Compliance Testing Laboratory Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2026-08-06
5745-5825 MHzOriginal Equipment2026-08-06

Exhibits

DocumentTypeAvailableFile
Label and label locationID Label/Location Info2026-08-06PDF 374.1 KB
Antenna informationTest Report2026-08-06PDF 1.1 MB
Appendix A test data 2G4WLAN part 1Test Report2026-08-06PDF 4.3 MB
Appendix A test data 2G4WLAN part 2Test Report2026-08-06PDF 4.1 MB
Appendix B test data 5GWLAN band 1 part 1Test Report2026-08-06PDF 3.5 MB
Appendix B test data 5GWLAN band 1 part 2Test Report2026-08-06PDF 3.9 MB
Appendix C test data 5GWLAN band 2A part 1Test Report2026-08-06PDF 3.6 MB
Appendix C test data 5GWLAN band 2A part 2Test Report2026-08-06PDF 3.8 MB
Appendix D test data 5GWLAN band 2C part 1Test Report2026-08-06PDF 4.1 MB
Appendix D test data 5GWLAN band 2C part 2Test Report2026-08-06PDF 4.2 MB
Appendix E test data 5GWLAN band 3 part 1Test Report2026-08-06PDF 3.6 MB
Appendix E test data 5GWLAN band 3 part 2Test Report2026-08-06PDF 3.9 MB
Test Report 2G4WLANTest Report2026-08-06PDF 1.6 MB
Test Report 5GWLAN band 1Test Report2026-08-06PDF 1.6 MB
Test Report 5GWLAN band 2Test Report2026-08-06PDF 2.3 MB
Test Report 5GWLAN band 3Test Report2026-08-06PDF 1.5 MB
Test Report DFSTest Report2026-08-06PDF 1.3 MB
Agent attestation letterAttestation Statements2026-08-06PDF 74.8 KB
Covered equipment letterAttestation Statements2026-08-06PDF 88.2 KB
Due digilence letterAttestation Statements2026-08-06PDF 247.2 KB
Confidentiality request letterCover Letter(s)2026-08-06PDF 86.9 KB
Confidentiality shortterm request letterCover Letter(s)2026-08-06PDF 92.6 KB
Letter of declaration disable channel 12 and 13 by softwareCover Letter(s)2026-08-06PDF 84.1 KB
RF exposure evaluationRF Exposure Info2026-08-06PDF 1.4 MB
User manual Metadata onlyUsers Manual2027-02-03PDF 564.8 KB
Internal photos Metadata onlyInternal Photos2027-02-03PDF 3.9 MB
External photos Metadata onlyExternal Photos2027-02-03PDF 2.4 MB
Test setup photos Metadata onlyTest Setup Photos2027-02-03PDF 1,001.7 KB
Block diagram Metadata onlyBlock DiagramPDF 110.8 KB
Schematic Metadata onlySchematicsPDF 1.7 MB
Letter of declaration unii device Metadata onlyOperational DescriptionPDF 135.5 KB
Letter of declaration unii device software configuration control Metadata onlyOperational DescriptionPDF 88.5 KB
Letter of declaration unii device software security requirements Metadata onlyOperational DescriptionPDF 128.4 KB
Operation description Metadata onlyOperational DescriptionPDF 492.8 KB

Application Information

Application IDpUq0fYgbUz+PkDWuXIzH9w==
Final Action Date2026-08-06
Application PurposeOriginal Equipment
Applicant FRN0030300776
ModelCMF04
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionMedia Measurement Gateway
Responsible PartyJoanna Drews, joanna@hyphametrics.com , +19176556475
Non-Technical ContactJoanna Drews, Hyphametrics, Inc., joanna@hyphametrics.com , (917)655-6475
Test FirmGavin Liang, Shenzhen LCS Compliance Testing Laboratory Ltd., gavin.liang@lcs-cert.com , 0755-82591330
TCB Emailo.kneip@kl-certification.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
pUq0fYgbUz+PkDWuXIzH9w==2026-08-06Original Equipment
aTDPXV7WvS3jMy+XEL97mg==2026-08-06Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.045815CCC MO
5180-5240 MHz0.071315ECC MO
5260-5320 MHz0.0815ECC MO ND
5500-5700 MHz0.096215ECC MO ND
5745-5825 MHz0.078915ECC MO

Grants

TCB Grant - Application pUq0fYgbUz+PkDWuXIzH9w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  KL-Certification GmbH
Heinrich-Hertz-Allee 7
St. Ingbert, 66386
Germany
Date of Grant: 08/06/2026

Application Dated: 08/06/2026
Hyphametrics,Inc.
149 E 23 Street
2052
NY, NY 10010
 
Attention: Joanna Drews , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYHD-CMF04
Name of Grantee:  Hyphametrics,Inc.
Equipment Class: Digital Transmission System
Notes: Media Measurement Gateway
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.0458  

Power listed is maximum average conducted output power. This device supports both 20 MHz and 40 MHz bandwidth modes as described in this filing. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. Device is client only containing 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. The device also contains 5GHz WLAN transmitters. Device also contains BT/WLAN modular (Model: AP6275S; FCC ID: ZQ6-AP6275S)

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application aTDPXV7WvS3jMy+XEL97mg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  KL-Certification GmbH
Heinrich-Hertz-Allee 7
St. Ingbert, 66386
Germany
Date of Grant: 08/06/2026

Application Dated: 08/06/2026
Hyphametrics,Inc.
149 E 23 Street
2052
NY, NY 10010
 
Attention: Joanna Drews , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYHD-CMF04
Name of Grantee:  Hyphametrics,Inc.
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Media Measurement Gateway
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.0713  
CC MO ND 15E 5260.0  -  5320.0 0.08  
CC MO ND 15E 5500.0  -  5700.0 0.0962  
CC MO 15E 5745.0  -  5825.0 0.0789  

Power listed is maximum average conducted output power. This device supports 20 MHz, 40 MHz and 80 MHz bandwidth modes as described in this filing. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. Device is client only containing 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. The device also contains 2.4GHz WLAN transmitters. Device also contains BT/WLAN modular (Model: AP6275S; FCC ID: ZQ6-AP6275S)

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).