FCC ID 2AYHY-CTH01

Smart Power Monitor Hub

by Xiamen Milesight IoT Co., Ltd.

Grantee Code: 2AYHY   Product Code: CTH01
Latest application date: 2026-07-10

FCC ID Device Details

FCC ID2AYHY-CTH01
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AYHY
Product CodeCTH01
Applicant BusinessXiamen Milesight IoT Co., Ltd. 🇨🇳
Related Domains ursalink.com milesight.com
Equipment ClassSmart Power Monitor Hub
Test FirmBay Area Compliance Laboratories Corp. (Dongguan)

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2026-07-10
902.3-927.6 MHzOriginal Equipment2026-07-10

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2026-07-10PDF 928.6 KB
Internal PhotosInternal Photos2026-07-10PDF 1.7 MB
External PhotosExternal Photos2026-07-10PDF 2.1 MB
Label and Label LocationID Label/Location Info2026-07-10PDF 449.3 KB
Test Setup PhotosTest Setup Photos2026-07-10PDF 459.7 KB
Antenna SpecificationTest Report2026-07-10PDF 478.1 KB
Antenna SpecificationTest Report2026-07-10PDF 1.7 MB
Test ReportTest Report2026-07-10PDF 4.6 MB
Test ReportTest Report2026-07-10PDF 5.5 MB
Attestation LetterAttestation Statements2026-07-10PDF 95.3 KB
Attestation Letter-2.911(d)(5)(i)(ii)Attestation Statements2026-07-10PDF 122.1 KB
US Agent Attestation LetterAttestation Statements2026-07-10PDF 77.3 KB
DoS LetterCover Letter(s)2026-07-10PDF 91.4 KB
FCC Agent Authorization LetterCover Letter(s)2026-07-10PDF 74.3 KB
FCC Confidentiality LetterCover Letter(s)2026-07-10PDF 92.5 KB
RF Exposure InformationRF Exposure Info2026-07-10PDF 171.8 KB
Block Diagram Metadata onlyBlock DiagramPDF 169.3 KB
Schematics Metadata onlySchematicsPDF 1.7 MB
Operation Description Metadata onlyOperational DescriptionPDF 204.3 KB

Application Information

Application IDvqykN0uS965XfO8QlQKDBQ==
Final Action Date2026-07-10
Application PurposeOriginal Equipment
Applicant FRN0030310346
ModelCTH01
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSmart Power Monitor Hub
Responsible PartyZhenlong Tong, tongzl@ursalink.com , 0592-5023060
Non-Technical ContactMichael Slack, MS Video Technology USA, sales@milesight.com , (185) 522-2460
Test FirmDavid Zhang, Bay Area Compliance Laboratories Corp. (Dongguan), qa.dg@baclcorp.com , 0086-769-8685-8891
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
vqykN0uS965XfO8QlQKDBQ==2026-07-10Original Equipment
qPpToz0ReuFqR90UKukrPg==2026-07-10Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.000715C
903-926.9 MHz0.103515C
902.3-927.6 MHz0.04915C

Grants

TCB Grant - Application vqykN0uS965XfO8QlQKDBQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratories Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 07/10/2026

Application Dated: 07/10/2026
Xiamen Milesight IoT Co., Ltd.
Building C09, Software Park Phase III,
Xiamen 361024,Fujian,,
China
 
Attention: Zhenlong Tong , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYHY-CTH01
Name of Grantee:  Xiamen Milesight IoT Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Smart Power Monitor Hub
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0007  
15C 903.0  -  926.9 0.1035  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

TCB Grant - Application qPpToz0ReuFqR90UKukrPg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratories Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 07/10/2026

Application Dated: 07/10/2026
Xiamen Milesight IoT Co., Ltd.
Building C09, Software Park Phase III,
Xiamen 361024,Fujian,,
China
 
Attention: Zhenlong Tong , Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYHY-CTH01
Name of Grantee:  Xiamen Milesight IoT Co., Ltd.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Smart Power Monitor Hub
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.3  -  927.6 0.049  

Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.