FCC ID 2AYQH-LE910CXWWX

Data Terminal Module

by EXFO Inc.

Grantee Code: 2AYQH   Product Code: LE910CXWWX
Latest application date: 2025-12-17

FCC ID Device Details

FCC ID2AYQH-LE910CXWWX
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2AYQH
Product CodeLE910CXWWX
Applicant BusinessEXFO Inc. 🇨🇦
Related Domains exfo.com
Equipment ClassData Terminal Module
Test FirmNemko Canada Inc. (Cambridge)

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2500-2570 MHzClass II permissive change or modification of presently authorized equipment2025-12-17
2500-2570 MHzChange in identification of presently authorized equipment. Original FCC ID: RI7LE910CXWWX Grant Date: 07/16/20212025-04-03

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2026-05-24PDF 3.4 MB
Users ManualUsers Manual2025-04-03PDF 4.8 MB
External PhotosExternal Photos2025-04-03PDF 178.9 KB
Label and LocationID Label/Location Info2025-04-03PDF 482.8 KB
Test setup photosTest Setup Photos2026-05-24PDF 537.8 KB
Antenna DetailsTest Report2025-12-17PDF 2.2 MB
Test ReportTest Report2025-12-17PDF 1.7 MB
Attestation statementAttestation Statements2025-12-17PDF 185 KB
Covered Equipment AttestationAttestation Statements2025-04-03PDF 274.2 KB
U.S. Agent Designation AttestationAttestation Statements2025-04-03PDF 185 KB
Agent letterCover Letter(s)2025-12-17PDF 318.5 KB
C2PC LetterCover Letter(s)2025-12-17PDF 203.7 KB
Confidentiality LetterCover Letter(s)2025-12-17PDF 201.8 KB
Agent Authorization LetterCover Letter(s)2025-04-03PDF 318.5 KB
Change of ID Request LetterCover Letter(s)2025-04-03PDF 503.9 KB
OEM Permission LetterCover Letter(s)2025-04-03PDF 189.8 KB
RF Exposure infoRF Exposure Info2025-12-17PDF 5.3 MB
Operational Description Metadata onlyOperational DescriptionPDF 5.3 MB

Application Information

Application IDOmLPHzl0NGZbyd8iHM/jAg==
Final Action Date2025-12-17
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0030438196
ModelLE910CXWWX
Frequency Range2500-2570 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionData Terminal Module
Responsible PartyPatrick Begin, patrick.begin@exfo.com , 514 856 2222
Non-Technical ContactTim Jennings, EXFO America Inc., tim.jennings@exfo.com
Test FirmCharles Neal, Nemko Canada Inc. (Cambridge), charles.neal@nemko.com , 613-737-9680
TCB Emailjin.xu@nemko.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentSingle Modular Approval
Composite DeviceNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
OmLPHzl0NGZbyd8iHM/jAg==2025-12-17Class II permissive change or modification of presently authorized equipment
q9q0VwI0Q2KOwvthM/daKQ==2025-04-03Change in identification of presently authorized equipment. Original FCC ID: RI7LE910CXWWX Grant Date: 07/16/2021

Equipment Authorization

FrequencyOutputToleranceGrant Notes
699-716 MHz0.1572.5ppm
699-716 MHz0.1242.5ppm
777-787 MHz0.1672.5ppm
777-787 MHz0.1332.5ppm
788-798 MHz0.1742.5ppmPF
788-798 MHz0.1422.5ppmPF
814-824 MHz0.2072.5ppm
814-824 MHz0.1622.5ppm
821.5 MHz0.2062.5ppm
821.5 MHz0.1582.5ppm
824-849 MHz0.1932.5ppm
824-849 MHz0.1682.5ppm
826.4-846.6 MHz0.2142.5ppm
897.5-900.5 MHz0.1432.5ppm
897.5-900.5 MHz0.1172.5ppm
1710-1755 MHz0.3872.5ppm
1710-1755 MHz0.3082.5ppm
1712.4-1752.6 MHz0.4122.5ppm
1850-1915 MHz0.3612.5ppm
1850-1915 MHz0.2842.5ppm
1850.2-1909.8 MHz1.3942.5ppm
1850.2-1909.8 MHz0.582.5ppm
1852.4-1907.6 MHz0.3982.5ppm
2500-2570 MHz0.3652.5ppm
2500-2570 MHz0.2912.5ppm

Grants

TCB Grant - Application q9q0VwI0Q2KOwvthM/daKQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, Inc.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 04/03/2025

Application Dated: 04/03/2025
EXFO Inc.
2500 Boul. Alfred-Nobel
Saint-Laurent, H4S 0A9
Canada
 
Attention: Patrick Begin , Dev Manager - Hardware

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYQH-LE910CXWWX
Name of Grantee:  EXFO Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Data Terminal Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.654 2.5  PM 247KGXW
22H 824.2  -  848.8 0.501 2.5  PM 242KG7W
22H 826.4  -  846.6 0.247 2.5  PM 4M14F9W
27 1712.4  -  1752.6 0.245 2.5  PM 4M14F9W
24E 1850.2  -  1909.8 0.947 2.5  PM 246KGXW
24E 1850.2  -  1909.8 0.394 2.5  PM 243KG7W
24E 1852.4  -  1907.6 0.27 2.5  PM 4M14F9W
27 699.0  -  716.0 0.234 2.5  PM 9M04G7D
27 699.0  -  716.0 0.185 2.5  PM 9M04W7D
27 777.0  -  787.0 0.225 2.5  PM 9M01G7D
27 777.0  -  787.0 0.179 2.5  PM 9M04W7D
PF 90 788.0  -  798.0 0.234 2.5  PM 9M01G7D
PF 90 788.0  -  798.0 0.191 2.5  PM 9M03W7D
90 814.0  -  824.0 0.239 2.5  PM 8M99G7D
90 814.0  -  824.0 0.187 2.5  PM 8M97W7D
22H, 90 821.5  -  821.5 0.238 2.5  PM 13M5G7D
22H, 90 821.5  -  821.5 0.182 2.5  PM 13M5W7D
22H 824.0  -  849.0 0.223 2.5  PM 13M5G7D
22H 824.0  -  849.0 0.194 2.5  PM 13M5W7D
27 897.5  -  900.5 0.165 2.5  PM 2M73G7D
27 897.5  -  900.5 0.135 2.5  PM 2M73W7D
27 1710.0  -  1755.0 0.23 2.5  PM 17M9G7D
27 1710.0  -  1755.0 0.183 2.5  PM 17M9W7D
24E 1850.0  -  1915.0 0.245 2.5  PM 18M0G7D
24E 1850.0  -  1915.0 0.193 2.5  PM 18M0W7D
27 2500.0  -  2570.0 0.24 2.5  PM 18M0G7D
27 2500.0  -  2570.0 0.191 2.5  PM 18M0W7D

Single Modular Approval. Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter evaluation procedures as documented in this filing. This device is to be used only for mobile and fixed application. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM integrators. OEM integrators must ensure that end-users are not provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance. The highest antenna gain including cable loss, must not exceed 8.51 dBi for Band 2 and Band 25, 5.5 dBi for Band 4, 6.91 dBi for Band 5 and Band 26, 9.91 dBi for Band 8, 9.7 dBi for Band 12, 9.91 dBi for Band 13 and 14, and 9.01 dBi for Band 7. This device supports 1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15MHz and 20 MHz bandwidth modes for LTE Bands 2/4/25; 1.4 MHz, 3 MHz, 5 MHz, 10 MHz and 15MHz bandwidth modes for LTE Band 26; 1.4 MHz, 3 MHz, 5 MHz and 10 MHz bandwidth modes for LTE Bands 5/12; 5 MHz, 10 MHz, 15MHz and 20 MHz bandwidth modes for LTE Bands 7; 1.4 MHz and 3 MHz for LTE Band 8; 5 MHz and 10 MHz bandwidth modes for LTE Bands 14/13. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations.

PF: Transmitter approved for Public Safety Broadband

TCB Grant - Application OmLPHzl0NGZbyd8iHM/jAg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, Inc.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 12/17/2025

Application Dated: 11/26/2025
EXFO Inc.
2500 Boul. Alfred-Nobel
Saint-Laurent, H4S 0A9
Canada
 
Attention: Patrick Begin , Dev Manager - Hardware

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2AYQH-LE910CXWWX
Name of Grantee:  EXFO Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Data Terminal Module
Modular Type: Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 1.654 2.5  PM 247KGXW
22H 824.2  -  848.8 0.501 2.5  PM 242KG7W
22H 826.4  -  846.6 0.247 2.5  PM 4M14F9W
27 1712.4  -  1752.6 0.245 2.5  PM 4M14F9W
24E 1850.2  -  1909.8 0.947 2.5  PM 246KGXW
24E 1850.2  -  1909.8 0.394 2.5  PM 243KG7W
24E 1852.4  -  1907.6 0.27 2.5  PM 4M14F9W
27 699.0  -  716.0 0.234 2.5  PM 9M04G7D
27 699.0  -  716.0 0.185 2.5  PM 9M04W7D
27 777.0  -  787.0 0.225 2.5  PM 9M01G7D
27 777.0  -  787.0 0.179 2.5  PM 9M04W7D
PF 90 788.0  -  798.0 0.234 2.5  PM 9M01G7D
PF 90 788.0  -  798.0 0.191 2.5  PM 9M01G7D
90 814.0  -  824.0 0.239 2.5  PM 8M99G7D
90 814.0  -  824.0 0.187 2.5  PM 8M97W7D
22H, 90 821.5  -  821.5 0.238 2.5  PM 13M5G7D
22H, 90 821.5  -  821.5 0.182 2.5  PM 13M5W7D
22H 824.0  -  849.0 0.223 2.5  PM 13M5G7D
22H 824.0  -  849.0 0.194 2.5  PM 13M5W7D
27 897.5  -  900.5 0.165 2.5  PM 2M73G7D
27 897.5  -  900.5 0.135 2.5  PM 2M73W7D
27 1710.0  -  1755.0 0.23 2.5  PM 17M9G7D
27 1710.0  -  1755.0 0.183 2.5  PM 17M9W7D
24E 1850.0  -  1915.0 0.245 2.5  PM 18M0G7D
24E 1850.0  -  1915.0 0.193 2.5  PM 18M0W7D
27 2500.0  -  2570.0 0.24 2.5  PM 18M0G7D
27 2500.0  -  2570.0 0.191 2.5  PM 18M0W7D

Class II Permissive Change to integrate this module for portable use into host platform model FTB-LITE with new antennas as described in this filing.

Single Modular Approval. Output power listed is conducted. The highest antenna gain is 4.5 dBi for all bands except for 1.8 GHz B2 the gain is 3.24 dBi. This device supports 1.4 MHz, 3 MHz, 5 MHz, 10 MHz, 15MHz and 20 MHz bandwidth modes for LTE Bands 2/4/25; 1.4 MHz, 3 MHz, 5 MHz, 10 MHz and 15MHz bandwidth modes for LTE Band 26; 1.4 MHz, 3 MHz, 5 MHz and 10 MHz bandwidth modes for LTE Bands 5/12; 5 MHz, 10 MHz, 15MHz and 20 MHz bandwidth modes for LTE Bands 7; 1.4 MHz and 3 MHz for LTE Band 8; 5 MHz and 10 MHz bandwidth modes for LTE Bands 14/13.

This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations.

The highest reported SAR is 1.48W/kg.


PF: Transmitter approved for Public Safety Broadband