FCC ID 2AYQM-M2W01
Handheld 3D Dimensioning Ternimal
by QBOID, Inc
Grantee Code: 2AYQM Product Code: M2W01
Latest application date: 2022-03-11
FCC ID Device Details
| FCC ID | 2AYQM-M2W01 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AYQM |
| Product Code | M2W01 |
| Applicant Business | QBOID, Inc 🇺🇸 |
| Related Domains | |
| Equipment Class | Handheld 3D Dimensioning Ternimal |
| Test Firm | TA Technology (Shanghai) Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2022-03-11 |
| 5180-5240 MHz | Original Equipment | 2022-03-11 |
| 2402-2480 MHz | Original Equipment | 2022-03-11 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2022-03-11 | PDF 685.7 KB |
| Internal photos | Internal Photos | 2022-03-11 | PDF 2.4 MB |
| External photos | External Photos | 2022-03-11 | PDF 1.1 MB |
| ID label and location | ID Label/Location Info | 2022-03-11 | PDF 40.9 KB |
| SAR Test set up | Test Setup Photos | 2022-03-11 | PDF 428.3 KB |
| Test setup photos | Test Setup Photos | 2022-03-11 | PDF 527.3 KB |
| Test setup photos | Test Setup Photos | 2022-03-11 | PDF 703.9 KB |
| Test setup photos | Test Setup Photos | 2022-03-11 | PDF 368 KB |
| SAR Test report | RF Exposure Info | 2022-03-11 | PDF 4.7 MB |
| Test reports | Test Report | 2022-03-11 | PDF 5.8 MB |
| Test reports | Test Report | 2022-03-11 | PDF 1.2 MB |
| Test reports | Test Report | 2022-03-11 | PDF 4.4 MB |
| Test reports | Test Report | 2022-03-11 | PDF 3.9 MB |
| POA | Attestation Statements | 2022-03-11 | PDF 116.6 KB |
| Confidentiality | Cover Letter(s) | 2022-03-11 | PDF 145.8 KB |
| Letter Authorization | Cover Letter(s) | 2022-03-11 | PDF 146.3 KB |
| Block Diagram Metadata only | Block Diagram | PDF 57.4 KB | |
| Block Diagram Metadata only | Block Diagram | PDF 40.9 KB | |
| Schematics Metadata only | Schematics | PDF 5.9 MB | |
| Operational Description Metadata only | Operational Description | PDF 1.5 MB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 102.5 KB | |
| Tune-up Procedure Metadata only | Parts List/Tune Up Info | PDF 78.2 KB |
Application Information
| Application ID | upTVdsjcIV00z8peGxwZtA== |
|---|---|
| Final Action Date | 2022-03-11 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0030441638 |
| Model | M2W01 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | Handheld 3D Dimensioning Ternimal |
| Responsible Party | Tony L Zuccarino, CMO, TONYZ@QBOID.AI |
| Technical Contact | Kai Xu, TA Technology(Shanghai) Company, Limited, xukai@ta-shanghai.com |
| Non-Technical Contact | Sun Yue, TA Technology(Shanghai) Company, Limited, sunyue@ta-shanghai.com |
| Test Firm | Mr. Zhihui Liu, TA Technology (Shanghai) Co., Ltd., liuzhihui@ta-shanghai.com |
| TCB Email | elabscert@applus.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, extremity(hand) and simultaneous transmission use conditions is <0.1 W/kg, <0.1 W/Kg and 0.27 W/kg ,respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| upTVdsjcIV00z8peGxwZtA== | 2022-03-11 | Original Equipment |
| hDrES48aaxtmbgLsV4p85g== | 2022-03-11 | Original Equipment |
| QNIF6aJJfdu6RODdGvmxnQ== | 2022-03-11 | Original Equipment |
| O1yFQcuSYofYwju00/qvmA== | 2022-03-11 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application upTVdsjcIV00z8peGxwZtA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 03/11/2022 Application Dated: 03/11/2022 |
| QBOID, Inc |
| 1057 Foxglove Pl |
| Unit 303P.O. Box 95131-1381, |
| San Jose, CA 95138 |
| Attention: Tony Zuccarino , CMO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AYQM-M2W01 |
| Name of Grantee: | QBOID, Inc |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Handheld 3D Dimensioning Ternimal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0041 |
| Output power listed is conducted. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, extremity(hand) and simultaneous transmission use conditions is <0.1 W/kg, <0.1 W/Kg and 0.27 W/kg ,respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application upTVdsjcIV00z8peGxwZtA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
QBOID, Inc 1057 Foxglove Pl Unit 303P.O. Box 95131-1381, San Jose, CA 95138 United States |
Date of Grant: 03/11/2022 Application Dated: 03/11/2022 |
| Attention: Tony Zuccarino , CMO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AYQM-M2W01 |
| Name of Grantee: | QBOID, Inc |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Handheld 3D Dimensioning Ternimal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0041 |
| Output power listed is conducted. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, extremity(hand) and simultaneous transmission use conditions is <0.1 W/kg, <0.1 W/Kg and 0.27 W/kg ,respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 03/11/2022 Application Dated: 03/11/2022 |
| QBOID, Inc |
| 1057 Foxglove Pl |
| Unit 303P.O. Box 95131-1381, |
| San Jose, CA 95138 |
| Attention: Tony Zuccarino , CMO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AYQM-M2W01 |
| Name of Grantee: | QBOID, Inc |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Handheld 3D Dimensioning Ternimal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC MO | 15E | 5180.0 - 5240.0 | 0.0594 | ||
| 38 CC MO ND | 15E | 5260.0 - 5320.0 | 0.0605 | ||
| 38 CC MO ND | 15E | 5500.0 - 5700.0 | 0.0632 | ||
| 38 CC MO | 15E | 5745.0 - 5825.0 | 0.0723 |
| Output power listed is conducted. The device contains 20MHz and 40MHz bandwidth.SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15 cm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. This device complies with the Dynamic Frequency Selection (DFS) requirements of KDB 905462 D03 as a Client only without Radar Detection. The highest reported SAR for body-worn accessory, extremity(hand) and simultaneous transmission use conditions is 0.24 W/kg, 0.72 W/kg and 0.27 W/kg ,respectively. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
EAS Grant - Application QNIF6aJJfdu6RODdGvmxnQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
QBOID, Inc 1057 Foxglove Pl Unit 303P.O. Box 95131-1381, San Jose, CA 95138 United States |
Date of Grant: 03/11/2022 Application Dated: 03/11/2022 |
| Attention: Tony Zuccarino , CMO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AYQM-M2W01 |
| Name of Grantee: | QBOID, Inc |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Handheld 3D Dimensioning Ternimal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC MO | 15E | 5180.0 - 5240.0 | 0.0594 | ||
| 38 CC MO ND | 15E | 5260.0 - 5320.0 | 0.0605 | ||
| 38 CC MO ND | 15E | 5500.0 - 5700.0 | 0.0632 | ||
| 38 CC MO | 15E | 5745.0 - 5825.0 | 0.0723 |
| Output power listed is conducted. The device contains 20MHz and 40MHz bandwidth.SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15 cm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. This device complies with the Dynamic Frequency Selection (DFS) requirements of KDB 905462 D03 as a Client only without Radar Detection. The highest reported SAR for body-worn accessory, extremity(hand) and simultaneous transmission use conditions is 0.24 W/kg, 0.72 W/kg and 0.27 W/kg ,respectively. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| ND: | This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h). |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 03/11/2022 Application Dated: 03/11/2022 |
| QBOID, Inc |
| 1057 Foxglove Pl |
| Unit 303P.O. Box 95131-1381, |
| San Jose, CA 95138 |
| Attention: Tony Zuccarino , CMO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AYQM-M2W01 |
| Name of Grantee: | QBOID, Inc |
| Equipment Class: | Digital Transmission System |
| Notes: | Handheld 3D Dimensioning Ternimal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0039 | ||
| CC MO | 15C | 2412.0 - 2462.0 | 0.0719 |
| Output power listed is conducted. The device contains 20MHz and 40MHz bandwidth.SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, extremity(hand) and simultaneous transmission use conditions is <0.1 W/kg, 0.18 W/kg and 0.27 W/kg ,respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application O1yFQcuSYofYwju00/qvmA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
QBOID, Inc 1057 Foxglove Pl Unit 303P.O. Box 95131-1381, San Jose, CA 95138 United States |
Date of Grant: 03/11/2022 Application Dated: 03/11/2022 |
| Attention: Tony Zuccarino , CMO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AYQM-M2W01 |
| Name of Grantee: | QBOID, Inc |
| Equipment Class: | Digital Transmission System |
| Notes: | Handheld 3D Dimensioning Ternimal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0039 | ||
| CC MO | 15C | 2412.0 - 2462.0 | 0.0719 |
| Output power listed is conducted. The device contains 20MHz and 40MHz bandwidth.SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory, extremity(hand) and simultaneous transmission use conditions is <0.1 W/kg, 0.18 W/kg and 0.27 W/kg ,respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
LGAI Technological Center S.A. (APPLUS) Ronda de la Font del Carme, s/n <BR>P.O. Box 08193, Barcelona, Spain |
Date of Grant: 03/11/2022 Application Dated: 03/11/2022 |
| QBOID, Inc |
| 1057 Foxglove Pl |
| Unit 303P.O. Box 95131-1381, |
| San Jose, CA 95138 |
| Attention: Tony Zuccarino , CMO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AYQM-M2W01 |
| Name of Grantee: | QBOID, Inc |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | Handheld 3D Dimensioning Ternimal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application hDrES48aaxtmbgLsV4p85g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
QBOID, Inc 1057 Foxglove Pl Unit 303P.O. Box 95131-1381, San Jose, CA 95138 United States |
Date of Grant: 03/11/2022 Application Dated: 03/11/2022 |
| Attention: Tony Zuccarino , CMO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AYQM-M2W01 |
| Name of Grantee: | QBOID, Inc |
| Equipment Class: | Part 15 Class B Computing Device Peripheral |
| Notes: | Handheld 3D Dimensioning Ternimal |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15B | - |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |