FCC ID 2AZEQ-B162
Wireless Earphone
by NOTHING TECHNOLOGY LIMITED
Grantee Code: 2AZEQ Product Code: B162
Latest application date: 2024-04-19
FCC ID Device Details
| FCC ID | 2AZEQ-B162 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AZEQ |
| Product Code | B162 |
| Applicant Business | NOTHING TECHNOLOGY LIMITED 🇬🇧 |
| Related Domains | |
| Equipment Class | Wireless Earphone |
| Test Firm | SGS-CSTC Standards Technical Services Co., Ltd. Sh |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2404-2478 MHz | Original Equipment | 2024-04-19 |
| 2402-2480 MHz | Original Equipment | 2024-04-18 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Package Label | Users Manual | 2024-10-16 | PDF 100.8 KB |
| User Manual | Users Manual | 2024-10-16 | PDF 5.8 MB |
| Internal Photos | Internal Photos | 2024-10-16 | PDF 1.5 MB |
| External Photos | External Photos | 2024-10-16 | PDF 688.3 KB |
| Label Declaration | ID Label/Location Info | 2024-04-19 | PDF 113.6 KB |
| SAR Test Setup Photo | Test Setup Photos | 2024-10-16 | PDF 396.5 KB |
| Test Setup Photos | Test Setup Photos | 2024-10-16 | PDF 296.4 KB |
| Antenna Information | Test Report | 2024-04-19 | PDF 1.8 MB |
| Antenna Information | Test Report | 2024-04-19 | PDF 1.8 MB |
| SAR Test Report | RF Exposure Info | 2024-04-19 | PDF 1.3 MB |
| SAR Test Report | RF Exposure Info | 2024-04-19 | PDF 5.5 MB |
| Test Report | Test Report | 2024-04-19 | PDF 5.6 MB |
| SAR Test Report | RF Exposure Info | 2024-04-18 | PDF 982.9 KB |
| Test Report | Test Report | 2024-04-18 | PDF 5.1 MB |
| Declaration Letter | Attestation Statements | 2024-04-19 | PDF 104.6 KB |
| US Agent | Attestation Statements | 2024-04-19 | PDF 125.6 KB |
| Authorization Letter | Cover Letter(s) | 2024-04-19 | PDF 15.8 KB |
| Confidentiality Letter | Cover Letter(s) | 2024-04-19 | PDF 67.7 KB |
| Block Diagram Metadata only | Block Diagram | PDF 670.5 KB | |
| Schematics Metadata only | Schematics | PDF 2.5 MB | |
| Operation Description Metadata only | Operational Description | PDF 86.8 KB | |
| Tune up Procedure Metadata only | Parts List/Tune Up Info | PDF 45.3 KB |
Application Information
| Application ID | JIFdNz/Re+E1UaE2jpBEsA== |
|---|---|
| Final Action Date | 2024-04-19 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0030725451 |
| Model | B162 |
| Frequency Range | 2404-2478 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Wireless Earphone |
| Responsible Party | Jathan Liu, jathan.liu@nothing.tech |
| Technical Contact | Keny Xu, SGS-CSTC Standards Technical Services Co., Ltd., Keny.Xu@sgs.com |
| Non-Technical Contact | Keny Xu, SGS-CSTC Standards Technical Services Co., Ltd., Keny.Xu@sgs.com |
| Test Firm | Keny Xu, SGS-CSTC Standards Technical Services Co., Ltd. Sh, Keny.Xu@sgs.com |
| TCB Email | USCTS.TCB@SGS.COM |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 10/16/2024 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is conducted. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. SAR compliance for head operating conditions is limited to the specific configurations tested for this filing. End-users must be informed of the head requirements to satisfy RF exposure compliance. The highest reported SAR for head exposure conditions is 1.30W/kg. SAR testing was performed to demonstrate RF compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| JIFdNz/Re+E1UaE2jpBEsA== | 2024-04-19 | Original Equipment |
| O1vPyPT+GY53hAatHudHmQ== | 2024-04-18 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application O1vPyPT+GY53hAatHudHmQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 04/18/2024 Application Dated: 04/18/2024 |
| NOTHING TECHNOLOGY LIMITED |
| 80 Cheapside, London, England EC2V 6EE |
| London, United Kingdom |
| Attention: Jathan Liu |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AZEQ-B162 |
| Name of Grantee: | NOTHING TECHNOLOGY LIMITED |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Wireless Earphone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0129 |
| Power output listed is conducted. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. SAR compliance for head operating conditions is limited to the specific configurations tested for this filing. End-users must be informed of the head requirements to satisfy RF exposure compliance. The highest reported SAR for head exposure conditions is 1.30W/kg. SAR testing was performed to demonstrate RF compliance. |
EAS Grant - Application O1vPyPT+GY53hAatHudHmQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
NOTHING TECHNOLOGY LIMITED 80 Cheapside, London, England EC2V 6EE London, United Kingdom |
Date of Grant: 04/18/2024 Application Dated: 04/18/2024 |
| Attention: Jathan Liu |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AZEQ-B162 |
| Name of Grantee: | NOTHING TECHNOLOGY LIMITED |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Wireless Earphone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0129 |
| Power output listed is conducted. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. SAR compliance for head operating conditions is limited to the specific configurations tested for this filing. End-users must be informed of the head requirements to satisfy RF exposure compliance. The highest reported SAR for head exposure conditions is 1.30W/kg. SAR testing was performed to demonstrate RF compliance. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 04/19/2024 Application Dated: 04/18/2024 |
| NOTHING TECHNOLOGY LIMITED |
| 80 Cheapside, London, England EC2V 6EE |
| London, United Kingdom |
| Attention: Jathan Liu |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AZEQ-B162 |
| Name of Grantee: | NOTHING TECHNOLOGY LIMITED |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless Earphone |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0045 | |||
| 15C | 2404.0 - 2478.0 | 0.0052 |
| Power output listed is conducted. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. SAR compliance for head operating conditions is limited to the specific configurations tested for this filing. End-users must be informed of the head requirements to satisfy RF exposure compliance. The highest reported SAR for head exposure conditions is 1.30W/kg. SAR testing was performed to demonstrate RF compliance. |
EAS Grant - Application JIFdNz/Re+E1UaE2jpBEsA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
NOTHING TECHNOLOGY LIMITED 80 Cheapside, London, England EC2V 6EE London, United Kingdom |
Date of Grant: 04/19/2024 Application Dated: 04/18/2024 |
| Attention: Jathan Liu |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AZEQ-B162 |
| Name of Grantee: | NOTHING TECHNOLOGY LIMITED |
| Equipment Class: | Digital Transmission System |
| Notes: | Wireless Earphone |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0045 | |||
| 15C | 2404.0 - 2478.0 | 0.0052 |
| Power output listed is conducted. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. SAR compliance for head operating conditions is limited to the specific configurations tested for this filing. End-users must be informed of the head requirements to satisfy RF exposure compliance. The highest reported SAR for head exposure conditions is 1.30W/kg. SAR testing was performed to demonstrate RF compliance. |
| Mail To: |