FCC ID 2AZLQ-T6
Delivery Robot
by Keenon Robotics Co., Ltd.
Grantee Code: 2AZLQ Product Code: T6
Latest application date: 2022-01-07
FCC ID Device Details
| FCC ID | 2AZLQ-T6 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AZLQ |
| Product Code | T6 |
| Applicant Business | Keenon Robotics Co., Ltd. 🇨🇳 |
| Related Domains | |
| Equipment Class | Delivery Robot |
| Test Firm | Intertek Testing Services Shanghai |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2022-01-07 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2022-01-07 | PDF 740.1 KB |
| Internal picture | Internal Photos | 2022-01-07 | PDF 1.9 MB |
| External picture | External Photos | 2022-01-07 | PDF 364 KB |
| Label and Location | ID Label/Location Info | 2022-01-07 | PDF 1.5 MB |
| test Setup | Test Setup Photos | 2022-01-07 | PDF 324.1 KB |
| report FCC IC part1 | Test Report | 2022-01-07 | PDF 5.1 MB |
| report FCC IC part2 | Test Report | 2022-01-07 | PDF 3.9 MB |
| report FCC IC part3 | Test Report | 2022-01-07 | PDF 3.9 MB |
| ACB-Form-FCC agent | Cover Letter(s) | 2022-01-07 | PDF 16.1 KB |
| ACB-Form-FCC-Confidentiality | Cover Letter(s) | 2022-01-07 | PDF 87.8 KB |
| Declaration letter for channel 12 and 13 | Cover Letter(s) | 2022-01-07 | PDF 24.9 KB |
| Report_FCC_MPE | RF Exposure Info | 2022-01-07 | PDF 302.5 KB |
| Confidential_Block Diagram Metadata only | Block Diagram | PDF 56.7 KB | |
| Confidential_Schematics Metadata only | Schematics | PDF 3.2 MB | |
| Confidential_operation description Metadata only | Operational Description | PDF 97.7 KB |
Application Information
| Application ID | Mq+BYwO3uDS38kil7sZMyA== |
|---|---|
| Final Action Date | 2022-01-07 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0030803456 |
| Model | T6 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Delivery Robot |
| Responsible Party | Spring Wang, certification@keenon.com |
| Technical Contact | Teddy Yin, Intertek Testing Services Shanghai, teddy.yin@intertek.com |
| Test Firm | Leah Xu, Intertek Testing Services Shanghai, leah.xu@intertek.com |
| TCB Email | hotline@acbcert.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has a 20 MHz and 40 MHz bandwidth mode. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| Mq+BYwO3uDS38kil7sZMyA== | 2022-01-07 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 2412-2462 MHz | 0.0400000 | 15C |
Grants
TCB Grant - Application Mq+BYwO3uDS38kil7sZMyA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
ACB, Inc. 6731 Whittier Avenue Suite C110 McLean, VA 22101 |
Date of Grant: 01/07/2022 Application Dated: 01/05/2022 |
| Keenon Robotics Co., Ltd. |
| 11F, Building 56, No. 1000, Jinhai Road, |
| Pudong District |
| shanghai, China |
| Attention: Spring Wang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AZLQ-T6 |
| Name of Grantee: | Keenon Robotics Co., Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Delivery Robot |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.04 |
| Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has a 20 MHz and 40 MHz bandwidth mode. |
EAS Grant - Application Mq+BYwO3uDS38kil7sZMyA==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Keenon Robotics Co., Ltd. 11F, Building 56, No. 1000, Jinhai Road, Pudong District shanghai, China |
Date of Grant: 01/07/2022 Application Dated: 01/05/2022 |
| Attention: Spring Wang |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AZLQ-T6 |
| Name of Grantee: | Keenon Robotics Co., Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Delivery Robot |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2412.0 - 2462.0 | 0.04 |
| Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. End users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device has a 20 MHz and 40 MHz bandwidth mode. |
| Mail To: |