FCC ID 2BA5U-RRU31717M

Ex10 UHF RFID Module(1-Port)

by Shenzhen RoyalRay Science and Technology Co., Ltd.

Grantee Code: 2BA5U   Product Code: RRU31717M
Latest application date: 2024-09-24

FCC ID Device Details

FCC ID2BA5U-RRU31717M
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BA5U
Product CodeRRU31717M
Applicant BusinessShenzhen RoyalRay Science and Technology Co., Ltd. 🇨🇳
Related Domains rr-rfid.com
Equipment ClassEx10 UHF RFID Module(1-Port)
Test FirmCTC Laboratories, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.75-927.25 MHzOriginal Equipment2024-09-24

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2024-09-24PDF 589.2 KB
Internal PhotosInternal Photos2024-09-24PDF 281.7 KB
External PhotosExternal Photos2024-09-24PDF 1.1 MB
LabelID Label/Location Info2024-09-24PDF 341.1 KB
Test SetupTest Setup Photos2024-09-24PDF 619.4 KB
Antenna SpecificationTest Report2024-09-24PDF 394.4 KB
TEST ReportTest Report2024-09-24PDF 2.3 MB
FCC Covered Equipment Certification Attestation LeAttestation Statements2024-09-24PDF 102.2 KB
FCC U.S. Agent DesignationAttestation Statements2024-09-24PDF 111.7 KB
Authority to Act as Agent - FCC.Cover Letter(s)2024-09-24PDF 69.5 KB
Difference declarationCover Letter(s)2024-09-24PDF 17.2 KB
Modular Approval LetterCover Letter(s)2024-09-24PDF 115 KB
Request for Confidentiality - FCCCover Letter(s)2024-09-24PDF 82.7 KB
RF Exposure InfoRF Exposure Info2024-09-24PDF 141.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 180.7 KB
Schematic Metadata onlySchematicsPDF 718.6 KB
Operational Description Metadata onlyOperational DescriptionPDF 98.9 KB

Application Information

Application IDimLCZYuVY1Sw5injRCQoGQ==
Final Action Date2024-09-24
Application PurposeOriginal Equipment
Applicant FRN0033760547
ModelRRU31717M
Frequency Range902.75-927.25 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionEx10 UHF RFID Module(1-Port)
Responsible PartyZOU YI, helenyang@rr-rfid.com , 13632745631
Test FirmTotti Zhao, CTC Laboratories, Inc., totti.zhao@sz-ctc.com.cn , +8675527521059
TCB Emailvina.kerai@nemko.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsModular Approval. Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antennas used for this transmitter as shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
imLCZYuVY1Sw5injRCQoGQ==2024-09-24Original Equipment

Equipment Authorization

FrequencyOutputRules
902.75-927.25 MHz0.722100015C

Grants

TCB Grant - Application imLCZYuVY1Sw5injRCQoGQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, Inc.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 09/24/2024

Application Dated: 09/24/2024
Shenzhen RoyalRay Science and Technology Co., Ltd.
ROOM 1001B, BUILDING 3RD, TIAN AN CLOUD PARK,
BANTIAN STREET, LONGGANG DISTRICT,
SHENZHEN,
China
 
Attention: ZOU YI

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BA5U-RRU31717M
Name of Grantee:  Shenzhen RoyalRay Science and Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Ex10 UHF RFID Module(1-Port)
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.75  -  927.25 0.7221  

Modular Approval. Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antennas used for this transmitter as shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application imLCZYuVY1Sw5injRCQoGQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen RoyalRay Science and Technology Co., Ltd.
ROOM 1001B, BUILDING 3RD, TIAN AN CLOUD PARK, BANTIAN STREET, LONGGANG DISTRICT,
SHENZHEN,
China
  Date of Grant: 09/24/2024

Application Dated: 09/24/2024
 
Attention: ZOU YI

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BA5U-RRU31717M
Name of Grantee:  Shenzhen RoyalRay Science and Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Ex10 UHF RFID Module(1-Port)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.75  -  927.25 0.7221  

Modular Approval. Power output listed is conducted. This grant is valid only when the module is sold to OEM integrators and must be installed by the OEM or OEM integrators. The antennas used for this transmitter as shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users may not be provided with the module installation instructions. OEM integrators and end-users must be provided with transmitter operating conditions for satisfying RF exposure compliance.



Mail To: