FCC ID 2BA8I-GAS-501F

Scent Machine

by Guangdong Grasse Environmental Technology Co.,Ltd.

Grantee Code: 2BA8I   Product Code: GAS501F
Latest application date: 2023-05-19

FCC ID Device Details

FCC ID2BA8I-GAS-501F
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BA8I
Product CodeGAS501F
Applicant BusinessGuangdong Grasse Environmental Technology Co.,Ltd. 🇨🇳
Related Domains grassearoma.com
Equipment ClassScent Machine
Test FirmShenzhen ZKT Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2023-05-19

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2023-05-19PDF 5 MB
Internal PhotosInternal Photos2023-05-19PDF 829 KB
External PhotoExternal Photos2023-05-19PDF 691.3 KB
Label LocationID Label/Location Info2023-05-19PDF 109.7 KB
Test Setup PhotosTest Setup Photos2023-05-19PDF 433.5 KB
Antenna SpecificationTest Report2023-05-19PDF 1.2 MB
Test Report2.4GWiFiTest Report2023-05-19PDF 3.2 MB
Test ReportBLETest Report2023-05-19PDF 3.1 MB
2.911 (d)(5)(i)CertificationEquipmentTypev1.2Attestation Statements2023-05-19PDF 219.2 KB
2.911 (d)(5)(ii)CertificiationApplicantv1.2Attestation Statements2023-05-19PDF 214.6 KB
2.911 (d)(7)USAgentforServiceofProcessv1.2Attestation Statements2023-05-19PDF 300.1 KB
AgentAuthorizationRev1.0Cover Letter(s)2023-05-19PDF 183.3 KB
Difference DescriptionCover Letter(s)2023-05-19PDF 179.2 KB
FCC Short_Long Term Confidentiality Request Rev4.1Cover Letter(s)2023-05-19PDF 161 KB
MPERF Exposure Info2023-05-19PDF 207.5 KB
Block Metadata onlyBlock DiagramPDF 97.4 KB
SCH Metadata onlySchematicsPDF 877.5 KB
OP Metadata onlyOperational DescriptionPDF 119.5 KB

Application Information

Application IDeMM8nRWfdJVq97h6T6qUnQ==
Final Action Date2023-05-19
Application PurposeOriginal Equipment
Applicant FRN0033781873
ModelGAS-501F
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionScent Machine
Responsible PartyZhubin Li, danny@grassearoma.com , +86-18622470932
Technical ContactGuangdong Grasse Environmental Technology Co.,Ltd., danny@grassearoma.com
Test FirmLake Xie, Shenzhen ZKT Technology Co., Ltd., zkt@zkt-lab.com , 0086-13620010775
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
eMM8nRWfdJVq97h6T6qUnQ==2023-05-19Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.0005915C
2412-2462 MHz0.0476415C

Grants

TCB Grant - Application eMM8nRWfdJVq97h6T6qUnQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 05/19/2023

Application Dated: 05/19/2023
Guangdong Grasse Environmental Technology Co.,Ltd.
No 670,GuangCong Five road, Zhongluotan Town,
Baiyun District,
Guangzhou,
China
 
Attention: Zhubin Li

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BA8I-GAS-501F
Name of Grantee:  Guangdong Grasse Environmental Technology Co.,Ltd.
Equipment Class: Digital Transmission System
Notes: Scent Machine
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00059  
15C 2412.0  -  2462.0 0.04764  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

EAS Grant - Application eMM8nRWfdJVq97h6T6qUnQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Guangdong Grasse Environmental Technology Co.,Ltd.
No 670,GuangCong Five road, Zhongluotan Town, Baiyun District,
Guangzhou,
China
  Date of Grant: 05/19/2023

Application Dated: 05/19/2023
 
Attention: Zhubin Li

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BA8I-GAS-501F
Name of Grantee:  Guangdong Grasse Environmental Technology Co.,Ltd.
Equipment Class: Digital Transmission System
Notes: Scent Machine
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00059  
15C 2412.0  -  2462.0 0.04764  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.



Mail To: