FCC ID 2BAH4SMG-3

Silvanet Mesh Gateway

by Dryad Networks GmbH

Grantee Code: 2BAH4   Product Code: SMG3
Latest application date: 2025-02-04

FCC ID Device Details

FCC ID2BAH4SMG-3
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BAH4
Product CodeSMG3
Applicant BusinessDryad Networks GmbH 🇩🇪
Related Domains dryad.net
Equipment ClassSilvanet Mesh Gateway
Test FirmSporton International Inc. Hsinhua Laboratory

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.3-914.9 MHzOriginal Equipment2025-02-04
923.3-927.5 MHzOriginal Equipment2025-02-04

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2025-08-03PDF 350.7 KB
Internal PhotosInternal Photos2025-08-03PDF 2.2 MB
External PhotosExternal Photos2025-08-03PDF 133.6 KB
Label InformationID Label/Location Info2025-02-04PDF 179.9 KB
TSUPTest Setup Photos2025-08-03PDF 267.1 KB
Antenna SpecificationsTest Report2025-02-04PDF 953.3 KB
Test ReportTest Report2025-02-04PDF 2.5 MB
Att Statements 2.911(d)(5)(7)Attestation Statements2025-02-04PDF 198.2 KB
Att Statements 2.911(d)(5)(i)&(ii)Attestation Statements2025-02-04PDF 82.9 KB
Confidentiality LetterCover Letter(s)2025-02-04PDF 149 KB
Multiple Model StatementCover Letter(s)2025-02-04PDF 85.1 KB
POA LetterCover Letter(s)2025-02-04PDF 97.8 KB
RF Exposure MPERF Exposure Info2025-02-04PDF 316.8 KB
Block Diagram Metadata onlyBlock DiagramPDF 398.1 KB
Schematics Metadata onlySchematicsPDF 750.2 KB
Operational Description Metadata onlyOperational DescriptionPDF 84.4 KB

Application Information

Application IDs1jf1RsOpmmKDkZfd0OI/Q==
Final Action Date2025-02-04
Application PurposeOriginal Equipment
Applicant FRN0033495649
ModelSMG-3
Frequency Range902.3-914.9 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionSilvanet Mesh Gateway
Responsible PartyMarcus Liu, Senior Certification Engineer, marcus.liu@dryad.net , 017636381895
Test FirmAlex Chen, Sporton International Inc. Hsinhua Laboratory, alex@sporton.com.tw , 886-3-327-3456
TCB Emailtei@timcoengr.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date08/03/2025
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
s1jf1RsOpmmKDkZfd0OI/Q==2025-02-04Original Equipment
2b+Rqj/H2sIZlZJ9MRCKdA==2025-02-04Original Equipment

Equipment Authorization

FrequencyOutputRules
902.3-914.9 MHz0.100500015C
903-914.2 MHz0.099315C
923.3-927.5 MHz0.09115C

Grants

TCB Grant - Application s1jf1RsOpmmKDkZfd0OI/Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 02/04/2025

Application Dated: 02/03/2025
Dryad Networks GmbH
Eisenbahnstr. 37
Eberswalde, 16225
Germany
 
Attention: Marcus Liu , Senior Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAH4SMG-3
Name of Grantee:  Dryad Networks GmbH
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Silvanet Mesh Gateway
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.3  -  914.9 0.1005  

Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance.

EAS Grant - Application s1jf1RsOpmmKDkZfd0OI/Q==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Dryad Networks GmbH
Eisenbahnstr. 37
Eberswalde, 16225
Germany
  Date of Grant: 02/04/2025

Application Dated: 02/03/2025
 
Attention: Marcus Liu , Senior Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAH4SMG-3
Name of Grantee:  Dryad Networks GmbH
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Silvanet Mesh Gateway
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.3  -  914.9 0.1005  

Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance.



TCB Grant - Application 2b+Rqj/H2sIZlZJ9MRCKdA==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 02/04/2025

Application Dated: 02/03/2025
Dryad Networks GmbH
Eisenbahnstr. 37
Eberswalde, 16225
Germany
 
Attention: Marcus Liu , Senior Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAH4SMG-3
Name of Grantee:  Dryad Networks GmbH
Equipment Class: Digital Transmission System
Notes: Silvanet Mesh Gateway
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 903.0  -  914.2 0.0993  
15C 923.3  -  927.5 0.091  

Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance.

EAS Grant - Application 2b+Rqj/H2sIZlZJ9MRCKdA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Dryad Networks GmbH
Eisenbahnstr. 37
Eberswalde, 16225
Germany
  Date of Grant: 02/04/2025

Application Dated: 02/03/2025
 
Attention: Marcus Liu , Senior Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAH4SMG-3
Name of Grantee:  Dryad Networks GmbH
Equipment Class: Digital Transmission System
Notes: Silvanet Mesh Gateway
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 903.0  -  914.2 0.0993  
15C 923.3  -  927.5 0.091  

Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance.



Mail To: