FCC ID 2BAH4WF-3

Silvanet Wildfire Sensor

by Dryad Networks GmbH

Grantee Code: 2BAH4   Product Code: WF3
Latest application date: 2025-03-18

FCC ID Device Details

FCC ID2BAH4WF-3
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BAH4
Product CodeWF3
Applicant BusinessDryad Networks GmbH 🇩🇪
Related Domains dryad.net
Equipment ClassSilvanet Wildfire Sensor
Test FirmSporton International Inc. Hsinhua Laboratory

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
903-914.2 MHzOriginal Equipment2025-03-18
902.3-914.9 MHzOriginal Equipment2025-03-18

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2025-09-14PDF 991.9 KB
Internal PhotosInternal Photos2025-09-14PDF 449.1 KB
External PhotosExternal Photos2025-09-14PDF 262.2 KB
Label Metadata onlyID Label/Location Info2025-03-18PDF 386.8 KB
Label InformationID Label/Location Info2025-03-18PDF 116.7 KB
TSUP LoRaTest Setup Photos2025-09-14PDF 870.1 KB
Antenna SpecTest Report2025-03-18PDF 324.9 KB
Test Report LoRaTest Report2025-03-18PDF 2.4 MB
Attestation Statement part 2.911(d)(7)Attestation Statements2025-03-18PDF 104.5 KB
Attstn Stmt part 2.911(d)(5)(i)&(ii)Attestation Statements2025-03-18PDF 154.9 KB
Confidentiality LetterCover Letter(s)2025-03-18PDF 168.2 KB
POA LetterCover Letter(s)2025-03-18PDF 138.1 KB
RF Exposure MPERF Exposure Info2025-03-18PDF 244.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 55.2 KB
Schematics Metadata onlySchematicsPDF 235.9 KB
Operational Description Metadata onlyOperational DescriptionPDF 82.8 KB

Application Information

Application ID5wO3bKx4xCxSx8MPoYHX4A==
Final Action Date2025-03-18
Application PurposeOriginal Equipment
Applicant FRN0033495649
ModelWF-3
Frequency Range903-914.2 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSilvanet Wildfire Sensor
Responsible PartyMarcus Liu, Senior Certification Engineer, marcus.liu@dryad.net , 017636381895
Test FirmAlex Chen, Sporton International Inc. Hsinhua Laboratory, alex@sporton.com.tw , 886-3-327-3456
TCB Emailtei@timcoengr.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date09/14/2025
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
5wO3bKx4xCxSx8MPoYHX4A==2025-03-18Original Equipment
/sehEK4t/8UQYVwY0fGCdQ==2025-03-18Original Equipment

Equipment Authorization

FrequencyOutput
902.3-914.9 MHz0.0219000
903-914.2 MHz0.0218
923.3-927.5 MHz0.0228

Grants

TCB Grant - Application 5wO3bKx4xCxSx8MPoYHX4A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 03/18/2025

Application Dated: 03/18/2025
Dryad Networks GmbH
Eisenbahnstr. 37
Eberswalde, 16225
Germany
 
Attention: Marcus Liu , Senior Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAH4WF-3
Name of Grantee:  Dryad Networks GmbH
Equipment Class: Digital Transmission System
Notes: Silvanet Wildfire Sensor
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 903.0  -  914.2 0.0218  
15C 923.3  -  927.5 0.0228  

Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance.

TCB Grant - Application /sehEK4t/8UQYVwY0fGCdQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  IIA Lab Services, LLC
13146 NW 86th Drive Suite 400
Alachua, FL 32615
Date of Grant: 03/18/2025

Application Dated: 03/18/2025
Dryad Networks GmbH
Eisenbahnstr. 37
Eberswalde, 16225
Germany
 
Attention: Marcus Liu , Senior Certification Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAH4WF-3
Name of Grantee:  Dryad Networks GmbH
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Silvanet Wildfire Sensor
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.3  -  914.9 0.0219  

Output Power listed is the maximum conducted output power. This device must be installed and operated so as to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. End-users must be informed of operating requirements for satisfying RF exposure compliance.