FCC ID 2BAH4WILDFIR-14

The Silvanet Wildfire Sensor is designed to detect forest fires during the early stages and to monitor the microclimate.

by Dryad Networks GmbH

Grantee Code: 2BAH4   Product Code: WILDFIR14
Latest application date: 2023-12-22

FCC ID Device Details

FCC ID2BAH4WILDFIR-14
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BAH4
Product CodeWILDFIR14
Applicant BusinessDryad Networks GmbH 🇩🇪
Related Domains dryad.net
Equipment ClassThe Silvanet Wildfire Sensor is designed to detect forest fires during the early stages and to monitor the microclimate.
Test Firmcetecom advanced GmbH

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902-928 MHzOriginal Equipment2023-12-22
902-928 MHzOriginal Equipment2023-12-22

Exhibits

DocumentTypeAvailableFile
Users_ManualUsers Manual2024-02-20PDF 5.2 MB
Internal_PhotosInternal Photos2024-02-20PDF 77.1 KB
Internal_PhotosInternal Photos2024-02-20PDF 250.3 KB
External_PhotosExternal Photos2024-02-20PDF 4.6 MB
External_PhotosExternal Photos2024-02-20PDF 991.3 KB
External_Photos 15BExternal Photos2024-02-20PDF 774.6 KB
ID_Label_Location_InfoID Label/Location Info2023-12-22PDF 138.2 KB
ID_Label_Location_InfoID Label/Location Info2023-12-22PDF 348.6 KB
Test_Setup_PhotosTest Setup Photos2024-02-20PDF 1.1 MB
Test_Setup_Photos_15BTest Setup Photos2024-02-20PDF 1 MB
Antenna_informationTest Report2023-12-22PDF 789.9 KB
Test_reportTest Report2023-12-22PDF 791.8 KB
Test_report diagramsTest Report2023-12-22PDF 4.9 MB
Test_report_15BTest Report2023-12-22PDF 334 KB
Test_report_15B_measurement_diagramsTest Report2023-12-22PDF 188.3 KB
2.911_Attestation_LetterAttestation Statements2023-12-22PDF 140 KB
2.911_Attestation_LetterAttestation Statements2023-12-22PDF 881.2 KB
Confidentiality_RequestCover Letter(s)2023-12-22PDF 88.5 KB
RF_Exposure_EvaluationRF Exposure Info2023-12-22PDF 535.3 KB
Block_Diagram Metadata onlyBlock DiagramPDF 22.1 KB
Schematics Metadata onlySchematicsPDF 107.4 KB
Operational_Description Metadata onlyOperational DescriptionPDF 116.6 KB
Parts_List Metadata onlyParts List/Tune Up InfoPDF 1.4 MB

Application Information

Application IDwKCO0t48UeAWEAxx8VR1Gg==
Final Action Date2023-12-22
Application PurposeOriginal Equipment
Applicant FRN0033495649
ModelWILDFIR-14
Frequency Range902-928 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionThe Silvanet Wildfire Sensor is designed to detect forest fires during the early stages and to monitor the microclimate.
Responsible PartyTirthkumar Brahmbhatt, tirth@dryad.net , 017636381895
Test FirmGerald Schmidt, cetecom advanced GmbH, gerald.schmidt@cetecomadvanced.com , +49 681 598 0
TCB Emailtcb-essen@cetecom.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date02/20/2024
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. A separation distance of at least 20 cm from all persons must be ensured.

Applications

Application IDDatePurpose
wKCO0t48UeAWEAxx8VR1Gg==2023-12-22Original Equipment
aV/O5tfN7J9q5iqmmd+McQ==2023-12-22Original Equipment
M0gz2oD7OLYNV98vvrMhHQ==2023-12-22Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
15BCC
902-928 MHz0.010300015CCC
902-928 MHz0.009160015CCC

Grants

TCB Grant - Application wKCO0t48UeAWEAxx8VR1Gg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  cetecom advanced GmbH
Untertuerkheimer Strasse 6-10
Saarbruecken, 66117
Germany
Date of Grant: 12/22/2023

Application Dated: 12/22/2023
Dryad Networks GmbH
Eisenbahnstr. 37
Eberswalde, 16225
Germany
 
Attention: Tirthkumar Brahmbhatt

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAH4WILDFIR-14
Name of Grantee:  Dryad Networks GmbH
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: The Silvanet Wildfire Sensor is designed to detect forest fires during the early stages and to monitor the microclimate.
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 902.0  -  928.0 0.0103  

Power output listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. A separation distance of at least 20 cm from all persons must be ensured.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application wKCO0t48UeAWEAxx8VR1Gg==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Dryad Networks GmbH
Eisenbahnstr. 37
Eberswalde, 16225
Germany
  Date of Grant: 12/22/2023

Application Dated: 12/22/2023
 
Attention: Tirthkumar Brahmbhatt

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAH4WILDFIR-14
Name of Grantee:  Dryad Networks GmbH
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: The Silvanet Wildfire Sensor is designed to detect forest fires during the early stages and to monitor the microclimate.
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 902.0  -  928.0 0.0103  

Power output listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. A separation distance of at least 20 cm from all persons must be ensured.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application M0gz2oD7OLYNV98vvrMhHQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  cetecom advanced GmbH
Untertuerkheimer Strasse 6-10
Saarbruecken, 66117
Germany
Date of Grant: 12/22/2023

Application Dated: 12/22/2023
Dryad Networks GmbH
Eisenbahnstr. 37
Eberswalde, 16225
Germany
 
Attention: Tirthkumar Brahmbhatt

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAH4WILDFIR-14
Name of Grantee:  Dryad Networks GmbH
Equipment Class: Part 15 Class B Digital Device
Notes: The Silvanet Wildfire Sensor is designed to detect forest fires during the early stages and to monitor the microclimate.
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application M0gz2oD7OLYNV98vvrMhHQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Dryad Networks GmbH
Eisenbahnstr. 37
Eberswalde, 16225
Germany
  Date of Grant: 12/22/2023

Application Dated: 12/22/2023
 
Attention: Tirthkumar Brahmbhatt

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAH4WILDFIR-14
Name of Grantee:  Dryad Networks GmbH
Equipment Class: Part 15 Class B Digital Device
Notes: The Silvanet Wildfire Sensor is designed to detect forest fires during the early stages and to monitor the microclimate.
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application aV/O5tfN7J9q5iqmmd+McQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  cetecom advanced GmbH
Untertuerkheimer Strasse 6-10
Saarbruecken, 66117
Germany
Date of Grant: 12/22/2023

Application Dated: 12/22/2023
Dryad Networks GmbH
Eisenbahnstr. 37
Eberswalde, 16225
Germany
 
Attention: Tirthkumar Brahmbhatt

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAH4WILDFIR-14
Name of Grantee:  Dryad Networks GmbH
Equipment Class: Digital Transmission System
Notes: The Silvanet Wildfire Sensor is designed to detect forest fires during the early stages and to monitor the microclimate.
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 902.0  -  928.0 0.00916  

Power output listed is average conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. A separation distance of at least 20 cm from all persons must be ensured.

CC: This device is certified pursuant to two different Part 15 rules sections.

EAS Grant - Application aV/O5tfN7J9q5iqmmd+McQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Dryad Networks GmbH
Eisenbahnstr. 37
Eberswalde, 16225
Germany
  Date of Grant: 12/22/2023

Application Dated: 12/22/2023
 
Attention: Tirthkumar Brahmbhatt

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAH4WILDFIR-14
Name of Grantee:  Dryad Networks GmbH
Equipment Class: Digital Transmission System
Notes: The Silvanet Wildfire Sensor is designed to detect forest fires during the early stages and to monitor the microclimate.
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 902.0  -  928.0 0.00916  

Power output listed is average conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. A separation distance of at least 20 cm from all persons must be ensured.


CC: This device is certified pursuant to two different Part 15 rules sections.

Mail To: