FCC ID 2BAI5-P600

Portable Power Station

by Zhejiang Huafon ESS Technology Co., Ltd.

Grantee Code: 2BAI5   Product Code: P600
Latest application date: 2023-04-27

FCC ID Device Details

FCC ID2BAI5-P600
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BAI5
Product CodeP600
Applicant BusinessZhejiang Huafon ESS Technology Co., Ltd. 🇨🇳
Related Domains huafeng.com
Equipment ClassPortable Power Station
Test FirmKSIGN (Guangdong) Testing Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2402-2480 MHzOriginal Equipment2023-04-27

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2023-04-27PDF 3.9 MB
Internal PhotosInternal Photos2023-04-27PDF 1.3 MB
External PhotosExternal Photos2023-04-27PDF 822.2 KB
LabelID Label/Location Info2023-04-27PDF 656.4 KB
Test photosTest Setup Photos2023-04-27PDF 359.1 KB
ANTTest Report2023-04-27PDF 728.7 KB
Test ReportTest Report2023-04-27PDF 4.5 MB
2.911 (d)(5)(i)CertificationEquipmentTypev1.2Attestation Statements2023-04-27PDF 317.1 KB
2.911 (d)(5)(ii)CertificiationApplicantv1.2Attestation Statements2023-04-27PDF 299.1 KB
2.911 (d)(7)USAgentforServiceofProcessv1.2Attestation Statements2023-04-27PDF 527.6 KB
AgentAuthorizationRev1.0Cover Letter(s)2023-04-27PDF 109.9 KB
FCC Short_Long Term Confidentiality Request Rev4.1Cover Letter(s)2023-04-27PDF 75 KB
BlockDiagram Metadata onlyBlock DiagramPDF 54.6 KB
SCH Metadata onlySchematicsPDF 2.3 MB
OP Metadata onlyOperational DescriptionPDF 771.2 KB

Application Information

Application IDXzFm0q5dGCXxP1TJ+3rlpw==
Final Action Date2023-04-27
Application PurposeOriginal Equipment
Applicant FRN0033523275
ModelP600
Frequency Range2402-2480 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionPortable Power Station
Responsible PartyFei Liu, liu.fei@huafeng.com , 17782816756
Technical ContactZhejiang Huafon ESS Technology Co., Ltd., liu.fei@huafeng.com
Test FirmNeil Wan, KSIGN (Guangdong) Testing Co., Ltd., info@gdksign.cn , +(86) 0755-2985 2678
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
XzFm0q5dGCXxP1TJ+3rlpw==2023-04-27Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.0015515C
2412-2462 MHz0.0648615C

Grants

TCB Grant - Application XzFm0q5dGCXxP1TJ+3rlpw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 04/27/2023

Application Dated: 04/27/2023
Zhejiang Huafon ESS Technology Co., Ltd.
Xincheng Industrial Park (Formerly Huafon
Industrial Park), Xincheng Sub-district,
Rui'an,Wenzhou, Zhejiang, China,
China
 
Attention: Fei Liu

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAI5-P600
Name of Grantee:  Zhejiang Huafon ESS Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Portable Power Station
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00155  
15C 2412.0  -  2462.0 0.06486  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

EAS Grant - Application XzFm0q5dGCXxP1TJ+3rlpw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Zhejiang Huafon ESS Technology Co., Ltd.
Xincheng Industrial Park (Formerly Huafon Industrial Park), Xincheng Sub-district,
Rui'an,Wenzhou, Zhejiang, China,
China
  Date of Grant: 04/27/2023

Application Dated: 04/27/2023
 
Attention: Fei Liu

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAI5-P600
Name of Grantee:  Zhejiang Huafon ESS Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Portable Power Station
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00155  
15C 2412.0  -  2462.0 0.06486  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.



Mail To: