FCC ID 2BAK2-F114

Smart Phone

by Shenzhen Qichang Intelligent Technology Co., Ltd

Grantee Code: 2BAK2   Product Code: F114
Latest application date: 2025-07-01

FCC ID Device Details

FCC ID2BAK2-F114
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BAK2
Product CodeF114
Applicant BusinessShenzhen Qichang Intelligent Technology Co., Ltd 🇨🇳
Related Domains fossibot.com
Equipment ClassSmart Phone
Test FirmShenzhen BCTC Testing Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5180-5240 MHzOriginal Equipment2025-07-01
2412-2462 MHzOriginal Equipment2025-07-01
2402-2480 MHzOriginal Equipment2025-07-01
13.56 MHzOriginal Equipment2025-07-01
699.7-715.3 MHzOriginal Equipment2025-07-01

Exhibits

DocumentTypeAvailableFile
User MannulUsers Manual2025-07-01PDF 2.2 MB
User ManualUsers Manual2025-07-01PDF 2.2 MB
User manualUsers Manual2025-07-01PDF 2.2 MB
Internal PhotosInternal Photos2025-07-01PDF 1.8 MB
Internal photoInternal Photos2025-07-01PDF 1.8 MB
Internal photosInternal Photos2025-07-01PDF 1.8 MB
External PhotosExternal Photos2025-07-01PDF 1.2 MB
External photosExternal Photos2025-07-01PDF 1.2 MB
external photoExternal Photos2025-07-01PDF 1.2 MB
Label & Label LocationID Label/Location Info2025-07-01PDF 266.5 KB
Label and LocationID Label/Location Info2025-07-01PDF 266.5 KB
Label and locationID Label/Location Info2025-07-01PDF 266.5 KB
label and label locationID Label/Location Info2025-07-01PDF 266.5 KB
label&label locationID Label/Location Info2025-07-01PDF 266.5 KB
Test Setup photo---DSSTest Setup Photos2025-07-01PDF 847 KB
Test Setup photo---NFCTest Setup Photos2025-07-01PDF 788 KB
Test Setup photo---PCETest Setup Photos2025-07-01PDF 729.2 KB
Test Setup photo---SARTest Setup Photos2025-07-01PDF 971.7 KB
Test photosTest Setup Photos2025-07-01PDF 971.7 KB
2.4GReport 1Test Report2025-07-01PDF 5.1 MB
2.4GReport 2Test Report2025-07-01PDF 2.5 MB
2G+3GReport 1Test Report2025-07-01PDF 4.8 MB
2G+3GReport 2Test Report2025-07-01PDF 3.2 MB
5.1+5.8GReport 1Test Report2025-07-01PDF 5 MB
5.1+5.8GReport 2Test Report2025-07-01PDF 4.8 MB
5.1+5.8GReport 3Test Report2025-07-01PDF 3.1 MB
ANTTest Report2025-07-01PDF 1.3 MB
BLE 2M ReportTest Report2025-07-01PDF 4.5 MB
BT3MReport 1Test Report2025-07-01PDF 4.8 MB
BT3MReport 2Test Report2025-07-01PDF 3.7 MB
LTE ReportTest Report2025-07-01PDF 2.6 MB
LTE Report12Test Report2025-07-01PDF 5 MB
LTE Report17Test Report2025-07-01PDF 2.9 MB
LTE Report2Test Report2025-07-01PDF 5.1 MB
LTE Report4Test Report2025-07-01PDF 5.1 MB
LTE Report5Test Report2025-07-01PDF 5 MB
LTE Report7Test Report2025-07-01PDF 5 MB
NFC ReportTest Report2025-07-01PDF 2.4 MB
NFC-ANTTest Report2025-07-01PDF 705.7 KB
2.911 (d)(5)(i)CertificationEquipmentTypev1.2Attestation Statements2025-07-01PDF 399.6 KB
2.911 (d)(5)(ii)CertificationApplicantv1.3Attestation Statements2025-07-01PDF 384.3 KB
2.911 (d)(5)(ii)CertificiationApplicantv1.2Attestation Statements2025-07-01PDF 384.3 KB
2.911 (d)(5)(ii)CertificiationApplicantv1.3Attestation Statements2025-07-01PDF 384.3 KB
2.911 (d)(7) US AgentAttestation Statements2025-07-01PDF 198.2 KB
2.911 (d)(7)USAgentforServiceofProcesAttestation Statements2025-07-01PDF 198.2 KB
2.911 (d)(7)USAgentforServiceofProcessv1.3Attestation Statements2025-07-01PDF 198.2 KB
2.911 (d)(7)USAgentforServiceofProcessv1.4Attestation Statements2025-07-01PDF 198.2 KB
2.911_(d)(7) US Agent for Service of Process v1.5Attestation Statements2025-07-01PDF 198.2 KB
Agent Authorization Rev 1.0Cover Letter(s)2025-07-01PDF 10.2 KB
AgentAuthorizationRev1.0Cover Letter(s)2025-07-01PDF 10.2 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2025-07-01PDF 110.9 KB
FCC Software Configuration Control Declaration Rev1.1Cover Letter(s)2025-07-01PDF 108.4 KB
Model DifferenceCover Letter(s)2025-07-01PDF 138.1 KB
SARReport 1RF Exposure Info2025-07-01PDF 4.9 MB
SARReport 2RF Exposure Info2025-07-01PDF 5 MB
SARReport 3RF Exposure Info2025-07-01PDF 4.3 MB
SAR_1RF Exposure Info2025-07-01PDF 4.9 MB
SAR_2RF Exposure Info2025-07-01PDF 5 MB
SAR_3RF Exposure Info2025-07-01PDF 4.3 MB
BLOCK Metadata onlyBlock DiagramPDF 206.2 KB
Block Metadata onlyBlock DiagramPDF 206.2 KB
Block Diagram Metadata onlyBlock DiagramPDF 206.2 KB
SCH Metadata onlySchematicsPDF 2.4 MB
OP Metadata onlyOperational DescriptionPDF 1.6 MB
Software security operational description Metadata onlySDR Software/Security Info.PDF 353 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 78.6 KB
Tune up Procedurer Metadata onlyParts List/Tune Up InfoPDF 220.2 KB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 220.2 KB

Application Information

Application IDqcowQW6nmaHpBb/4YDs+dw==
Final Action Date2025-07-01
Application PurposeOriginal Equipment
Applicant FRN0033538703
ModelF114
Frequency Range5180-5240 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionSmart Phone
Responsible PartyWenwen Jiang, jiangww@fossibot.com , +86-755-81797123
Technical ContactShenzhen Qichang Intelligent Technology Co., Ltd, jiangww@fossibot.com
Test FirmSally He, Shenzhen BCTC Testing Co., Ltd., sally.he@bctc-lab.com.cn , 15999690624
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is the maximum conducted output power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory are 0.53 W/kg, 0.42 W/kg, 0.61 W/kg and 1.47 W/kg respectively.

Applications

Application IDDatePurpose
qcowQW6nmaHpBb/4YDs+dw==2025-07-01Original Equipment
juKNqfvbPo985yLG23EE/g==2025-07-01Original Equipment
HiSXC0af/XWjaGOkTusSSQ==2025-07-01Original Equipment
EeV6ghLUXFREcD6x7Q2U0A==2025-07-01Original Equipment
CJG9X1RN1jpJiFS+8yyTjw==2025-07-01Original Equipment

Equipment Authorization

FrequencyOutputToleranceGrant Notes
13.56 MHzCC
699.7-715.3 MHz0.0940.013ppm
699.7-715.3 MHz0.090.015ppm
704-711 MHz0.0910.015ppm
704-711 MHz0.0860.016ppm
709-711 MHz0.0920.021ppm
709-711 MHz0.0860.015ppm
824.2-848.8 MHz0.56360.0092ppm
824.7-848.5 MHz0.0990.012ppm
826.4-846.6 MHz0.24770.0107ppm
829-844 MHz0.0940.011ppm
829-844 MHz0.090.012ppm
1711.5-1753.5 MHz0.3110.013ppm
1712.4-1752.6 MHz0.19280.0113ppm
1720-1745 MHz0.3290.016ppm
1720-1745 MHz0.2740.017ppm
1850.2-1909.8 MHz0.58750.0106ppm
1851.5-1908.5 MHz0.2960.012ppm
1851.5-1908.5 MHz0.3050.016ppm
1852.4-1907.6 MHz0.21280.0116ppm
1860-1900 MHz0.2540.011ppm
1860-1900 MHz0.2990.015ppm
2402-2480 MHz0.0014CC
2402-2480 MHz0.0016000CC
2412-2462 MHz0.0214CC
2505-2565 MHz0.2830.017ppm
2510-2560 MHz0.3250.017ppm
2510-2560 MHz0.2480.018ppm
5180-5240 MHz0.0123CC
5745-5825 MHz0.0305CC

Grants

TCB Grant - Application qcowQW6nmaHpBb/4YDs+dw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/01/2025

Application Dated: 07/01/2025
Shenzhen Qichang Intelligent Technology Co., Ltd
Room 510,Building 7,Yunli Intelligent Park,No.7
Bantian Street,Longgang
Shenzhen,
China
 
Attention: Wenwen Jiang ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAK2-F114
Name of Grantee:  Shenzhen Qichang Intelligent Technology Co., Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Smart Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15E 5180.0  -  5240.0 0.0123  
CC 15E 5745.0  -  5825.0 0.0305  

Power listed is the maximum conducted output power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory are 0.53 W/kg, 0.42 W/kg, 0.61 W/kg and 1.47 W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application juKNqfvbPo985yLG23EE/g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/01/2025

Application Dated: 07/01/2025
Shenzhen Qichang Intelligent Technology Co., Ltd
Room 510,Building 7,Yunli Intelligent Park,No.7
Bantian Street,Longgang
Shenzhen,
China
 
Attention: Wenwen Jiang ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAK2-F114
Name of Grantee:  Shenzhen Qichang Intelligent Technology Co., Ltd
Equipment Class: Digital Transmission System
Notes: Smart Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0014  
CC 15C 2412.0  -  2462.0 0.0214  

Power listed is the maximum conducted output power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory are 0.21 W/kg, 0.19 W/kg, 0.13 W/kg and 1.47 W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application HiSXC0af/XWjaGOkTusSSQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/01/2025

Application Dated: 07/01/2025
Shenzhen Qichang Intelligent Technology Co., Ltd
Room 510,Building 7,Yunli Intelligent Park,No.7
Bantian Street,Longgang
Shenzhen,
China
 
Attention: Wenwen Jiang ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAK2-F114
Name of Grantee:  Shenzhen Qichang Intelligent Technology Co., Ltd
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Smart Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.0016  

Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn and simultaneous SAR accessory are 0.08 W/kg, 0.08 W/kg and 1.47 W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application EeV6ghLUXFREcD6x7Q2U0A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/01/2025

Application Dated: 07/01/2025
Shenzhen Qichang Intelligent Technology Co., Ltd
Room 510,Building 7,Yunli Intelligent Park,No.7
Bantian Street,Longgang
Shenzhen,
China
 
Attention: Wenwen Jiang ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAK2-F114
Name of Grantee:  Shenzhen Qichang Intelligent Technology Co., Ltd
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Smart Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application CJG9X1RN1jpJiFS+8yyTjw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 07/01/2025

Application Dated: 07/01/2025
Shenzhen Qichang Intelligent Technology Co., Ltd
Room 510,Building 7,Yunli Intelligent Park,No.7
Bantian Street,Longgang
Shenzhen,
China
 
Attention: Wenwen Jiang ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BAK2-F114
Name of Grantee:  Shenzhen Qichang Intelligent Technology Co., Ltd
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Smart Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.6223 0.0092  PM 249KGXW
24E 1850.2  -  1909.8 0.6012 0.0106  PM 247KGXW
22H 824.2  -  848.8 0.5636 0.0092  PM 248KG7W
24E 1850.2  -  1909.8 0.5875 0.0106  PM 249KG7W
24E 1852.4  -  1907.6 0.2128 0.0116  PM 4M16F9W
27 1712.4  -  1752.6 0.1928 0.0113  PM 4M16F9W
22H 826.4  -  846.6 0.2477 0.0107  PM 4M18F9W
24E 1851.5  -  1908.5 0.305 0.016  PM 2M72G7D
24E 1860.0  -  1900.0 0.299 0.015  PM 18M0G7D
24E 1860.0  -  1900.0 0.254 0.011  PM 18M0W7D
24E 1851.5  -  1908.5 0.296 0.012  PM 2M72W7D
27 1720.0  -  1745.0 0.329 0.016  PM 18M0G7D
27 1720.0  -  1745.0 0.274 0.017  PM 18M0W7D
27 1711.5  -  1753.5 0.311 0.013  PM 2M72W7D
22H 824.7  -  848.5 0.099 0.012  PM 1M10G7D
22H 829.0  -  844.0 0.094 0.011  PM 8M99G7D
22H 829.0  -  844.0 0.09 0.012  PM 9M00W7D
27 2510.0  -  2560.0 0.325 0.017  PM 18M0G7D
27 2510.0  -  2560.0 0.248 0.018  PM 18M0W7D
27 2505.0  -  2565.0 0.283 0.017  PM 9M01W7D
27 699.7  -  715.3 0.094 0.013  PM 1M11G7D
27 704.0  -  711.0 0.091 0.015  PM 9M00G7D
27 704.0  -  711.0 0.086 0.016  PM 9M01W7D
27 699.7  -  715.3 0.09 0.015  PM 1M10W7D
27 709.0  -  711.0 0.092 0.021  PM 9M02G7D
27 709.0  -  711.0 0.086 0.015  PM 9M01W7D

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn, hotspot and simultaneous SAR accessory are 0.74 W/kg, 1.03 W/kg, 0.83 W/kg and 1.47 W/kg respectively.