FCC ID 2BAR7-KUN-DC1000
NON-CONTACT SLEEP MONITOR
by Hunan Zennze Technology Limited
Grantee Code: 2BAR7 Product Code: KUNDC1000
Latest application date: 2023-08-29
FCC ID Device Details
| FCC ID | 2BAR7-KUN-DC1000 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2BAR7 |
| Product Code | KUNDC1000 |
| Applicant Business | Hunan Zennze Technology Limited 🇨🇳 |
| Related Domains | |
| Equipment Class | NON-CONTACT SLEEP MONITOR |
| Test Firm | Shenzhen Anbotek Compliance Laboratory Limited |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 7200 MHz | Original Equipment | 2023-08-29 |
| 2412-2462 MHz | Original Equipment | 2023-08-29 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2023-08-29 | PDF 4.4 MB |
| Internal photo | Internal Photos | 2023-08-29 | PDF 779.6 KB |
| External photo | External Photos | 2023-08-29 | PDF 2.1 MB |
| label and location | ID Label/Location Info | 2023-08-29 | PDF 181.8 KB |
| Test setup photo | Test Setup Photos | 2023-08-29 | PDF 2.2 MB |
| 18220WC30133001 FCC-WLAN Appendix Data | Test Report | 2023-08-29 | PDF 2.8 MB |
| 18220WC30133001- ReportFCC15.247 Wi-Fi2.4G | Test Report | 2023-08-29 | PDF 1.3 MB |
| 18220WC30133002_Report FCC 15.517_UWB | Test Report | 2023-08-29 | PDF 1.4 MB |
| Antenna spec | Test Report | 2023-08-29 | PDF 1,011.9 KB |
| Antenna spec | Test Report | 2023-08-29 | PDF 387.5 KB |
| Certification Applicant | Attestation Statements | 2023-08-29 | PDF 115.8 KB |
| Certification Equipment Type | Attestation Statements | 2023-08-29 | PDF 120.1 KB |
| US Agent | Attestation Statements | 2023-08-29 | PDF 325.8 KB |
| Agent Authorization | Cover Letter(s) | 2023-08-29 | PDF 85.9 KB |
| Confidentiality Request letter | Cover Letter(s) | 2023-08-29 | PDF 70.5 KB |
| PAG check list | Cover Letter(s) | 2023-08-29 | PDF 162.8 KB |
| RF exposure report | RF Exposure Info | 2023-08-29 | PDF 144.7 KB |
| Block diagram Metadata only | Block Diagram | PDF 115.6 KB | |
| Schematic Metadata only | Schematics | PDF 302.9 KB | |
| Operation description Metadata only | Operational Description | PDF 78.9 KB |
Application Information
| Application ID | znuQU7xOzpuJsdvdkIgT+A== |
|---|---|
| Final Action Date | 2023-08-29 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0033625922 |
| Model | KUN-DC1000 |
| Frequency Range | 7200 MHz |
| Equipment Class | UWB - Ultra Wideband Transmitter |
| Device Description | NON-CONTACT SLEEP MONITOR |
| Responsible Party | Hui Feng, fenghui7265@dingtalk.com |
| Technical Contact | Hunan Zennze Technology Limited, fenghui7265@dingtalk.com |
| Test Firm | Jeff Zhu, Shenzhen Anbotek Compliance Laboratory Limited, jeff.zhu@anbotek.com |
| TCB Email | certification@micomlabs.com |
| TCB Scope | A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
| Grant Comments | The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| znuQU7xOzpuJsdvdkIgT+A== | 2023-08-29 | Original Equipment |
| C6KeFs6/QODEO4pYWQwqVw== | 2023-08-29 | Original Equipment |
Grants
TCB Grant - Application znuQU7xOzpuJsdvdkIgT+A==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 08/29/2023 Application Dated: 08/17/2023 |
| Hunan Zennze Technology Limited |
| Apartment 501, Xianglu International Garden II |
| Hotel No. 61 Lufeng Road, High-tech |
| Development Zone, Changsha, 410221 China |
| Attention: Hui Feng |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BAR7-KUN-DC1000 |
| Name of Grantee: | Hunan Zennze Technology Limited |
| Equipment Class: | Ultra Wideband Transmitter |
| Notes: | NON-CONTACT SLEEP MONITOR |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15F | 7200.0 - 7200.0 |
| The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application znuQU7xOzpuJsdvdkIgT+A==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hunan Zennze Technology Limited Apartment 501, Xianglu International Garden II Hotel No. 61 Lufeng Road, High-tech Development Zone, Changsha, 410221 China |
Date of Grant: 08/29/2023 Application Dated: 08/17/2023 |
| Attention: Hui Feng |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BAR7-KUN-DC1000 |
| Name of Grantee: | Hunan Zennze Technology Limited |
| Equipment Class: | Ultra Wideband Transmitter |
| Notes: | NON-CONTACT SLEEP MONITOR |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15F | 7200.0 - 7200.0 |
| The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 08/29/2023 Application Dated: 08/17/2023 |
| Hunan Zennze Technology Limited |
| Apartment 501, Xianglu International Garden II |
| Hotel No. 61 Lufeng Road, High-tech |
| Development Zone, Changsha, 410221 China |
| Attention: Hui Feng |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BAR7-KUN-DC1000 |
| Name of Grantee: | Hunan Zennze Technology Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | NON-CONTACT SLEEP MONITOR |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.0586 |
| Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
EAS Grant - Application C6KeFs6/QODEO4pYWQwqVw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Hunan Zennze Technology Limited Apartment 501, Xianglu International Garden II Hotel No. 61 Lufeng Road, High-tech Development Zone, Changsha, 410221 China |
Date of Grant: 08/29/2023 Application Dated: 08/17/2023 |
| Attention: Hui Feng |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BAR7-KUN-DC1000 |
| Name of Grantee: | Hunan Zennze Technology Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | NON-CONTACT SLEEP MONITOR |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.0586 |
| Output power listed is conducted power. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| Mail To: |