FCC ID 2BATD-CS-WP6
Fitness walker
by Yongkang Saihan Technology Co.,Ltd
Grantee Code: 2BATD Product Code: CSWP6
Latest application date: 2023-05-10
FCC ID Device Details
| FCC ID | 2BATD-CS-WP6 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2BATD |
| Product Code | CSWP6 |
| Applicant Business | Yongkang Saihan Technology Co.,Ltd 🇨🇳 |
| Equipment Class | Fitness walker |
| Test Firm | Shenzhen LCS Compliance Testing Laboratory Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2402-2480 MHz | Original Equipment | 2023-05-10 |
| 2402-2480 MHz | Original Equipment | 2023-05-10 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| user manual | Users Manual | 2023-05-10 | PDF 758.5 KB |
| Internal Photos | Internal Photos | 2023-05-10 | PDF 4.5 MB |
| External Photos | External Photos | 2023-05-10 | PDF 734.9 KB |
| Label and Location | ID Label/Location Info | 2023-05-10 | PDF 333.1 KB |
| Test Setup Photos | Test Setup Photos | 2023-05-10 | PDF 1.3 MB |
| Antenna_Specification | Test Report | 2023-05-10 | PDF 914.8 KB |
| Appendix A Test Data for BT_FCC _Part1 | Test Report | 2023-05-10 | PDF 5.8 MB |
| Appendix A Test Data for BT_FCC _Part2 | Test Report | 2023-05-10 | PDF 3.2 MB |
| Appendix B Test Data for BT LE_FCC | Test Report | 2023-05-10 | PDF 4 MB |
| BT LE Test Report | Test Report | 2023-05-10 | PDF 1.3 MB |
| BT Test Report | Test Report | 2023-05-10 | PDF 1.2 MB |
| Covered Equipment Attestation_2.911(d)(5)(i) and (ii) | Attestation Statements | 2023-05-10 | PDF 61 KB |
| US_Agent_2.911(d)(7) V04 | Attestation Statements | 2023-05-10 | PDF 178.5 KB |
| Declaration Letter of Model Difference | Cover Letter(s) | 2023-05-10 | PDF 71.9 KB |
| FCC Confidentiality request letter | Cover Letter(s) | 2023-05-10 | PDF 107.3 KB |
| FCC POA | Cover Letter(s) | 2023-05-10 | PDF 110.8 KB |
| RF Exposure Evaluation-FCC | RF Exposure Info | 2023-05-10 | PDF 351.1 KB |
| Block Diagram Metadata only | Block Diagram | PDF 180.4 KB | |
| schematic Metadata only | Schematics | PDF 269.9 KB | |
| Operation Description Metadata only | Operational Description | PDF 108.4 KB |
Application Information
| Application ID | ozss/8yXwcC9z2K7A52JHw== |
|---|---|
| Final Action Date | 2023-05-10 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0033640913 |
| Model | CS-WP6 |
| Frequency Range | 2402-2480 MHz |
| Equipment Class | DSS - Part 15 Spread Spectrum Transmitter |
| Device Description | Fitness walker |
| Responsible Party | Guangyi Luo, 376213769@qq.com |
| Test Firm | Gavin Liang, Shenzhen LCS Compliance Testing Laboratory Ltd., gavin.liang@lcs-cert.com |
| TCB Email | joergkusig@eurofins.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| ozss/8yXwcC9z2K7A52JHw== | 2023-05-10 | Original Equipment |
| Ggp2EaTETUN11kdEDNU7iw== | 2023-05-10 | Original Equipment |
Grants
TCB Grant - Application ozss/8yXwcC9z2K7A52JHw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 05/10/2023 Application Dated: 05/10/2023 |
| Yongkang Saihan Technology Co.,Ltd |
| NO.666 Sifang Road,Chengxi New District |
| Yongkang, Zhejiang, 321399 China |
| Attention: Guangyi Luo |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BATD-CS-WP6 |
| Name of Grantee: | Yongkang Saihan Technology Co.,Ltd |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Fitness walker |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0019 |
| Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
EAS Grant - Application ozss/8yXwcC9z2K7A52JHw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Yongkang Saihan Technology Co.,Ltd NO.666 Sifang Road,Chengxi New District Yongkang, Zhejiang, 321399 China |
Date of Grant: 05/10/2023 Application Dated: 05/10/2023 |
| Attention: Guangyi Luo |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BATD-CS-WP6 |
| Name of Grantee: | Yongkang Saihan Technology Co.,Ltd |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Fitness walker |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0019 |
| Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 05/10/2023 Application Dated: 05/10/2023 |
| Yongkang Saihan Technology Co.,Ltd |
| NO.666 Sifang Road,Chengxi New District |
| Yongkang, Zhejiang, 321399 China |
| Attention: Guangyi Luo |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BATD-CS-WP6 |
| Name of Grantee: | Yongkang Saihan Technology Co.,Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Fitness walker |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0005 |
| Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
EAS Grant - Application Ggp2EaTETUN11kdEDNU7iw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Yongkang Saihan Technology Co.,Ltd NO.666 Sifang Road,Chengxi New District Yongkang, Zhejiang, 321399 China |
Date of Grant: 05/10/2023 Application Dated: 05/10/2023 |
| Attention: Guangyi Luo |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BATD-CS-WP6 |
| Name of Grantee: | Yongkang Saihan Technology Co.,Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Fitness walker |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0005 |
| Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
| Mail To: |