FCC ID 2BB59-F2400-US

RESIDENTIAL ESS & PORTABLE POWER STATION

by RUNHOOD POWER INC.

Grantee Code: 2BB59   Product Code: F2400US
Latest application date: 2024-08-15

FCC ID Device Details

FCC ID2BB59-F2400-US
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BB59
Product CodeF2400US
Applicant BusinessRUNHOOD POWER INC. 🇺🇸
Related Domains runhoodpower.com
Equipment ClassRESIDENTIAL ESS & PORTABLE POWER STATION
Test FirmKSIGN (Guangdong) Testing Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2024-08-15

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2024-08-15PDF 911.7 KB
Internal PhotosInternal Photos2024-08-15PDF 2 MB
External PhotosExternal Photos2024-08-15PDF 2.3 MB
LABELID Label/Location Info2024-08-15PDF 709.8 KB
Test photosTest Setup Photos2024-08-15PDF 378.7 KB
ANTTest Report2024-08-15PDF 777.2 KB
Test Report 47CFRPart15.247 BLETest Report2024-08-15PDF 4.3 MB
Test Report 47CFRPart15.247 WIFITest Report2024-08-15PDF 3.9 MB
2.911 (d)(5)(i) Certification Equipment Type v1.2Attestation Statements2024-08-15PDF 141.8 KB
2.911 (d)(5)(ii) Certificiation Applicant v1.3Attestation Statements2024-08-15PDF 136.5 KB
2.911 (d)(7) US Agent for Service of Process v1.4Attestation Statements2024-08-15PDF 138.3 KB
Agent Authorization Rev 1.0Cover Letter(s)2024-08-15PDF 107 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2024-08-15PDF 83.6 KB
MPERF Exposure Info2024-08-15PDF 557.7 KB
Block Diagram Metadata onlyBlock DiagramPDF 156.7 KB
SCH Metadata onlySchematicsPDF 3.2 MB
OP Metadata onlyOperational DescriptionPDF 879.1 KB

Application Information

Application IDlPuFGPpagOYn3DsZg4a1zw==
Final Action Date2024-08-15
Application PurposeOriginal Equipment
Applicant FRN0034026419
ModelF2400-US
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionRESIDENTIAL ESS & PORTABLE POWER STATION
Responsible PartyQin Wei, Deputy general manager of R&D;, wei.qin@runhoodpower.com , +86-021-57766651
Technical ContactRUNHOOD POWER INC., wei.qin@runhoodpower.com
Test FirmNeil Wan, KSIGN (Guangdong) Testing Co., Ltd., info@gdksign.cn , +(86) 0755-2985 2678
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is the maximum conducted output power. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
lPuFGPpagOYn3DsZg4a1zw==2024-08-15Original Equipment

Equipment Authorization

FrequencyOutputRules
2402-2480 MHz0.0002215C
2412-2462 MHz0.0281815C

Grants

TCB Grant - Application lPuFGPpagOYn3DsZg4a1zw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 08/15/2024

Application Dated: 08/15/2024
RUNHOOD POWER INC.
3980-D Valley Blvd,
Walnut, CA 91789
 
Attention: Qin Wei , Deputy general manager of R&D

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BB59-F2400-US
Name of Grantee:  RUNHOOD POWER INC.
Equipment Class: Digital Transmission System
Notes: RESIDENTIAL ESS & PORTABLE POWER STATION
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00022  
15C 2412.0  -  2462.0 0.02818  

Power listed is the maximum conducted output power. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

EAS Grant - Application lPuFGPpagOYn3DsZg4a1zw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

RUNHOOD POWER INC.
3980-D Valley Blvd,
Walnut, CA 91789
United States
  Date of Grant: 08/15/2024

Application Dated: 08/15/2024
 
Attention: Qin Wei , Deputy general manager of R&D

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BB59-F2400-US
Name of Grantee:  RUNHOOD POWER INC.
Equipment Class: Digital Transmission System
Notes: RESIDENTIAL ESS & PORTABLE POWER STATION
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.00022  
15C 2412.0  -  2462.0 0.02818  

Power listed is the maximum conducted output power. The antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.



Mail To: