FCC ID 2BCAP000002

Flat Panel Detector

by Medicatech USA

Grantee Code: 2BCAP   Product Code: 000002
Latest application date: 2026-04-13

FCC ID Device Details

FCC ID2BCAP000002
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BCAP
Product Code000002
Applicant BusinessMedicatech USA 🇺🇸
Related Domains medicatechusa.com
Equipment ClassFlat Panel Detector
Test FirmShenzhen LCS Compliance Testing Laboratory Ltd.

Linked Records

Barcode records decoded from published FCC label exhibits or linked by an explicit FCC ID reference on a product page.

UPC / GTINLinked product
20251200012025
GTIN-14
Flat Panel Detector
Brand: Medicatech USA · Model: 000002
Source: FCC label

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
5745-5825 MHzOriginal Equipment2026-04-13
2412-2462 MHzOriginal Equipment2026-04-13

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2026-10-11PDF 3.1 MB
Internal photos part 1Internal Photos2026-10-11PDF 5.4 MB
Internal photos part 2Internal Photos2026-10-11PDF 4.3 MB
External photosExternal Photos2026-10-11PDF 1.2 MB
Exxternal photosExternal Photos2026-10-11PDF 1.2 MB
Label and label locationID Label/Location Info2026-04-13PDF 175.4 KB
Block diagramBlock Diagram2026-04-13PDF 154.2 KB
Test setup photosTest Setup Photos2026-10-11PDF 1.1 MB
Antenna informationTest Report2026-04-13PDF 796.7 KB
Appendix A test data 2G4WLAN part 1Test Report2026-04-13PDF 5.2 MB
Appendix A test data 2G4WLAN part 2Test Report2026-04-13PDF 5 MB
Appendix A test data 2G4WLAN part 3Test Report2026-04-13PDF 2.3 MB
Appendix B test data 5GWLAN band 1 part 1Test Report2026-04-13PDF 5 MB
Appendix B test data 5GWLAN band 1 part 2Test Report2026-04-13PDF 4.8 MB
Appendix B test data 5GWLAN band 1 part 3Test Report2026-04-13PDF 2.2 MB
Appendix C test data 5GWLAN band 2A part 1Test Report2026-04-13PDF 5 MB
Appendix C test data 5GWLAN band 2A part 2Test Report2026-04-13PDF 5.4 MB
Appendix D test data 5GWLAN band 2C part 1Test Report2026-04-13PDF 4.6 MB
Appendix D test data 5GWLAN band 2C part 2Test Report2026-04-13PDF 4.9 MB
Appendix D test data 5GWLAN band 2C part 3Test Report2026-04-13PDF 4.1 MB
Appendix E test data 5GWLAN band 3 part 1Test Report2026-04-13PDF 5.1 MB
Appendix E test data 5GWLAN band 3 part 2Test Report2026-04-13PDF 5.4 MB
Test Report 2G4WLANTest Report2026-04-13PDF 2.2 MB
Test Report 5GWLAN band 1Test Report2026-04-13PDF 2.2 MB
Test Report 5GWLAN band 2Test Report2026-04-13PDF 3.3 MB
Test Report 5GWLAN band 3Test Report2026-04-13PDF 2.1 MB
Test Report DFSTest Report2026-04-13PDF 4.5 MB
Agent attestation letterAttestation Statements2026-04-13PDF 88.1 KB
Covered equipment letterAttestation Statements2026-04-13PDF 87.9 KB
Due digilence letterAttestation Statements2026-04-13PDF 87.1 KB
Confidentiality request letterCover Letter(s)2026-04-13PDF 87.9 KB
Confidentiality shortterm request letterCover Letter(s)2026-04-13PDF 114.9 KB
Letter of declaration disable channel 12 and 13 by softwareCover Letter(s)2026-04-13PDF 86.9 KB
Letter of declaration model differenceCover Letter(s)2026-04-13PDF 142.5 KB
RF exposure evaluationRF Exposure Info2026-04-13PDF 2.1 MB
Schematic Metadata onlySchematicsPDF 2.2 MB
Letter of declaration unii device Metadata onlyOperational DescriptionPDF 76.7 KB
Letter of declaration unii device software configuration control Metadata onlyOperational DescriptionPDF 115.4 KB
Letter of declaration unii device software security requirements Metadata onlyOperational DescriptionPDF 66.7 KB
Operation description Metadata onlyOperational DescriptionPDF 749 KB

Application Information

Application IDjKCyX1ZzdarBpUMzhRec6Q==
Final Action Date2026-04-13
Application PurposeOriginal Equipment
Applicant FRN0034063842
Model000002
Frequency Range5745-5825 MHz
Equipment ClassNII - Unlicensed National Information Infrastructure TX
Device DescriptionFlat Panel Detector
Responsible PartyGeorge Makar, george@medicatechusa.com , 9496792881
Non-Technical ContactGeorge Makar, Medicatech USA, george@medicatechusa.com , (949)679-2882
Test FirmGavin Liang, Shenzhen LCS Compliance Testing Laboratory Ltd., gavin.liang@lcs-cert.com , 0755-82591330
TCB Emailo.kneip@kl-certification.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
jKCyX1ZzdarBpUMzhRec6Q==2026-04-13Original Equipment
MuMkum5eRwShWY3teDRq4g==2026-04-13Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.014115CCC MO
5180-5240 MHz0.011115ECC MO
5250 MHz0.007515ECC MO ND
5260-5320 MHz0.01215ECC MO ND
5500-5700 MHz0.009615ECC MO ND
5745-5825 MHz0.009115ECC MO

Grants

TCB Grant - Application MuMkum5eRwShWY3teDRq4g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  KL-Certification GmbH
Heinrich-Hertz-Allee 7
St. Ingbert, 66386
Germany
Date of Grant: 04/13/2026

Application Dated: 04/13/2026
Medicatech USA
1245 N. Patt St
Anaheom, CA 92801
 
Attention: George Makar , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BCAP000002
Name of Grantee:  Medicatech USA
Equipment Class: Digital Transmission System
Notes: Flat Panel Detector
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15C 2412.0  -  2462.0 0.0141  

Power listed is maximum average conducted output power. This device supports both 20 MHz and 40 MHz bandwidth modes as described in this filing. This filing meets the SAR threshold exclusion set forth in KDB 447498 and therefore can be used in mobile/portable configurations. The antenna used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Device is a client only containing 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. This device also contains 5GWLAN transmitters.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application jKCyX1ZzdarBpUMzhRec6Q==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  KL-Certification GmbH
Heinrich-Hertz-Allee 7
St. Ingbert, 66386
Germany
Date of Grant: 04/13/2026

Application Dated: 04/13/2026
Medicatech USA
1245 N. Patt St
Anaheom, CA 92801
 
Attention: George Makar , President

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BCAP000002
Name of Grantee:  Medicatech USA
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: Flat Panel Detector
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.0111  
CC MO ND 15E 5250.0  -  5250.0 0.0075  
CC MO ND 15E 5260.0  -  5320.0 0.012  
CC MO ND 15E 5500.0  -  5700.0 0.0096  
CC MO 15E 5745.0  -  5825.0 0.0091  

Power listed is maximum average conducted output power. The device supports 20 MHz, 40 MHz, 80MHz and 160 MHz bandwidth modes as described in this filing. This filing meets the SAR threshold exclusion set forth in KDB 447498 and therefore can be used in mobile/portable configurations. The antenna used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Device is a client only containing 2 x 2 MIMO configuration, enabled for either 2.4 or 5 GHz band operations as described in this filing. The device also contains 2.4GHz WLAN transmitters.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).