FCC ID 2BCUQ-Y501WY
SIP Intercom/SIP Care Intercom
by Fanvil Link Technology Co.,LTD
Grantee Code: 2BCUQ Product Code: Y501WY
Latest application date: 2025-07-28
FCC ID Device Details
| FCC ID | 2BCUQ-Y501WY |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2BCUQ |
| Product Code | Y501WY |
| Applicant Business | Fanvil Link Technology Co.,LTD 🇨🇳 |
| Related Domains | |
| Equipment Class | SIP Intercom/SIP Care Intercom |
| Test Firm | Shenzhen Accurate Technology Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Change in identification of presently authorized equipment. Original FCC ID: 2APPZ-Y501WY Grant Date: 06/13/2023 | 2025-07-28 |
| 5180-5240 MHz | Change in identification of presently authorized equipment. Original FCC ID: 2APPZ-Y501WY Grant Date: 06/13/2023 | 2025-07-28 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| External Photos | External Photos | 2026-01-24 | PDF 3 MB |
| Label & Label Location | ID Label/Location Info | 2025-07-28 | PDF 1.3 MB |
| 2.911 (d)(5)(i) Attestation Statement | Attestation Statements | 2025-07-28 | PDF 18.1 KB |
| 2.911 (d)(5)(ii) Attestation Statement | Attestation Statements | 2025-07-28 | PDF 18.3 KB |
| US Agent Attestation Letter | Attestation Statements | 2025-07-28 | PDF 20.7 KB |
| Authorization Letter from Original Grantee | Cover Letter(s) | 2025-07-28 | PDF 36.3 KB |
| Change in ID Request Letter | Cover Letter(s) | 2025-07-28 | PDF 37.4 KB |
| DoS Letter | Cover Letter(s) | 2025-07-28 | PDF 45.7 KB |
| FCC Agent Authorization Letter | Cover Letter(s) | 2025-07-28 | PDF 19 KB |
| FCC Short term Confidentiality Request | Cover Letter(s) | 2025-07-28 | PDF 26.6 KB |
Application Information
| Application ID | W5Sg+eGZqP48TEXja0M6Hg== |
|---|---|
| Final Action Date | 2025-07-28 |
| Application Purpose | Change in identification of presently authorized equipment. Original FCC ID: 2APPZ-Y501WY Grant Date: 06/13/2023 |
| Applicant FRN | 0034227223 |
| Model | Y501WY |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | SIP Intercom/SIP Care Intercom |
| Responsible Party | mengjiao Hu, emc@fanvil.com |
| Test Firm | Hazel Li, Shenzhen Accurate Technology Co., Ltd., qa@atc-lab.com |
| TCB Email | bacl.regulatory@baclcorp.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 01/24/2026 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| W5Sg+eGZqP48TEXja0M6Hg== | 2025-07-28 | Change in identification of presently authorized equipment. Original FCC ID: 2APPZ-Y501WY Grant Date: 06/13/2023 |
| Nypzxr9t0eW3sq6B1PM1zQ== | 2025-07-28 | Change in identification of presently authorized equipment. Original FCC ID: 2APPZ-Y501WY Grant Date: 06/13/2023 |
Equipment Authorization
Grants
TCB Grant - Application W5Sg+eGZqP48TEXja0M6Hg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratories Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 07/28/2025 Application Dated: 07/28/2025 |
| Fanvil Link Technology Co.,LTD |
| 13th Floor, Building 2, Runzhi R&D Center, |
| Xin'an Street, Bao'an District, |
| Shenzhen, Guangdong, 518000 China |
| Attention: mengjiao Hu , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BCUQ-Y501WY |
| Name of Grantee: | Fanvil Link Technology Co.,LTD |
| Equipment Class: | Digital Transmission System |
| Notes: | SIP Intercom/SIP Care Intercom |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.0415 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application Nypzxr9t0eW3sq6B1PM1zQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Bay Area Compliance Laboratories Corp. 1274 Anvilwood Avenue Sunnyvale, CA 94089 |
Date of Grant: 07/28/2025 Application Dated: 07/28/2025 |
| Fanvil Link Technology Co.,LTD |
| 13th Floor, Building 2, Runzhi R&D Center, |
| Xin'an Street, Bao'an District, |
| Shenzhen, Guangdong, 518000 China |
| Attention: mengjiao Hu , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BCUQ-Y501WY |
| Name of Grantee: | Fanvil Link Technology Co.,LTD |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | SIP Intercom/SIP Care Intercom |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0365 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.0381 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. This device supports 20 MHz and 40 MHz bandwidth modes. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |