FCC ID 2BD5N-S1N1PRO
Robotic Pool Cleaner
by Shenzhen Aiper Intelligent Co.,Ltd.
Grantee Code: 2BD5N Product Code: S1N1PRO
Latest application date: 2025-11-20
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Class II permissive change or modification of presently authorized equipment | 2025-11-20 |
| 2412-2462 MHz | Class II permissive change or modification of presently authorized equipment | 2025-11-19 |
| 2402-2480 MHz | Class II permissive change or modification of presently authorized equipment | 2025-03-26 |
| 2402-2480 MHz | Class II permissive change or modification of presently authorized equipment | 2024-07-03 |
| 2402-2480 MHz | Original Equipment | 2024-05-07 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2025-11-20 | PDF 5.3 MB |
| user manual | Users Manual | 2025-11-19 | PDF 5.3 MB |
| user manual | Users Manual | 2025-03-26 | PDF 4.8 MB |
| user manual | Users Manual | 2025-03-26 | PDF 4.6 MB |
| User manual_Part1 | Users Manual | 2024-07-03 | PDF 5.2 MB |
| User manual_Part2 | Users Manual | 2024-07-03 | PDF 4.8 MB |
| User manual_Part1 | Users Manual | 2024-05-07 | PDF 4.6 MB |
| User manual_Part2 | Users Manual | 2024-05-07 | PDF 4.8 MB |
| Internal Photos | Internal Photos | 2025-11-20 | PDF 1.2 MB |
| internal photo | Internal Photos | 2025-11-19 | PDF 1.2 MB |
| Internalphoto | Internal Photos | 2025-03-26 | PDF 1.2 MB |
| Internal photos | Internal Photos | 2024-05-07 | PDF 2.6 MB |
| External Photos | External Photos | 2025-11-20 | PDF 2.3 MB |
| external photo | External Photos | 2025-11-19 | PDF 2.3 MB |
| Externalphoto | External Photos | 2025-03-26 | PDF 1 MB |
| External photos | External Photos | 2024-07-03 | PDF 1.9 MB |
| External photos | External Photos | 2024-05-07 | PDF 1.2 MB |
| Label and Label location | ID Label/Location Info | 2025-11-20 | PDF 2.7 MB |
| label and location | ID Label/Location Info | 2025-11-19 | PDF 2.7 MB |
| Test Setup Photo | Test Setup Photos | 2025-11-20 | PDF 2.1 MB |
| test photo | Test Setup Photos | 2025-11-19 | PDF 2.1 MB |
| Test Setup Photos | Test Setup Photos | 2025-03-26 | PDF 178.8 KB |
| Test setup photos | Test Setup Photos | 2024-07-03 | PDF 67.2 KB |
| Test setup photos | Test Setup Photos | 2024-05-07 | PDF 204.3 KB |
| Test Report | Test Report | 2025-11-20 | PDF 1.3 MB |
| test report | Test Report | 2025-11-19 | PDF 1.3 MB |
| Tets report | Test Report | 2025-03-26 | |
| Tets report | Test Report | 2025-03-26 | PDF 2.8 MB |
| Tets report Metadata only | Test Report | 2025-03-26 | PDF 1,018.9 KB |
| 2.4G WIFI Test Report | Test Report | 2024-07-03 | PDF 1.9 MB |
| BLE Test Report_Part1 | Test Report | 2024-07-03 | PDF 4.4 MB |
| BLE Test Report_Part2 | Test Report | 2024-07-03 | PDF 2.2 MB |
| 2.4G WIFI Test Report | Test Report | 2024-05-07 | PDF 3.9 MB |
| Antenna_report | Test Report | 2024-05-07 | PDF 807 KB |
| Appendix RF test data for BLE | Test Report | 2024-05-07 | PDF 1.2 MB |
| Appendix RF test data for WIFI2.4G | Test Report | 2024-05-07 | PDF 4.3 MB |
| BLE Test Report | Test Report | 2024-05-07 | PDF 5.5 MB |
| Attestation Statements of US Agent for Service of Process, 2.911(d)(7) | Attestation Statements | 2025-11-20 | PDF 101.9 KB |
| Attestation of Covered Equipment, 2.911(d)(5)(i)(ii) | Attestation Statements | 2025-11-20 | PDF 64.2 KB |
| Attestation_Statements_part_2.911_d__5__i__and_2.911_d__5__ii_(7) | Attestation Statements | 2025-11-19 | PDF 64.2 KB |
| USA agent letter | Attestation Statements | 2025-11-19 | PDF 101.9 KB |
| Attestation Statements part | Attestation Statements | 2025-03-26 | |
| Attestation Statements part | Attestation Statements | 2025-03-26 | PDF 66.9 KB |
| US AGENT | Attestation Statements | 2025-03-26 | PDF 101.9 KB |
| Covered Equipment Attestation_2.911(d)(5)(i) and (ii) | Attestation Statements | 2024-07-03 | PDF 63 KB |
| US_Agent_2.911(d)(7)-U_V05 | Attestation Statements | 2024-07-03 | PDF 16.5 KB |
| Covered Equipment Attestation_2.911(d)(5)(i) and (ii) | Attestation Statements | 2024-05-07 | PDF 62.8 KB |
| ANT Report | Cover Letter(s) | 2025-11-20 | PDF 595.7 KB |
| Agent Authorization Letter Template | Cover Letter(s) | 2025-11-20 | PDF 129 KB |
| FCC Class II PC request letter | Cover Letter(s) | 2025-11-20 | PDF 337.3 KB |
| FCC Short & Long Term Confidentiality Request | Cover Letter(s) | 2025-11-20 | PDF 88.8 KB |
| ANT spe | Cover Letter(s) | 2025-11-19 | PDF 595.7 KB |
| Agent Authorization Letter | Cover Letter(s) | 2025-11-19 | PDF 129 KB |
| C2PC letter | Cover Letter(s) | 2025-11-19 | PDF 337.3 KB |
| ANT Report | Cover Letter(s) | 2025-03-26 | PDF 807 KB |
| Agent Authorization Letter Template | Cover Letter(s) | 2025-03-26 | PDF 128.9 KB |
| Class II PC request letter | Cover Letter(s) | 2025-03-26 | PDF 905.3 KB |
| Declaration Letter of Model Difference | Cover Letter(s) | 2025-03-26 | PDF 28.1 KB |
| Short & Long Term Confidentiality Request | Cover Letter(s) | 2025-03-26 | PDF 88.8 KB |
| CIIPC Request letter -FCC | Cover Letter(s) | 2024-07-03 | PDF 208.7 KB |
| Declaration Letter of Model Difference | Cover Letter(s) | 2024-07-03 | PDF 68.1 KB |
| FCC Confidentiality request letter | Cover Letter(s) | 2024-07-03 | PDF 110.5 KB |
| FCC Declaration of Disable WLAN Channel 12 and 13 | Cover Letter(s) | 2024-07-03 | PDF 116.2 KB |
| FCC POA | Cover Letter(s) | 2024-07-03 | PDF 114 KB |
| FCC Confidentiality request letter | Cover Letter(s) | 2024-05-07 | PDF 110.8 KB |
| FCC Declaration of Disable WLAN Channel 12 and 13 | Cover Letter(s) | 2024-05-07 | PDF 115.8 KB |
| FCC POA | Cover Letter(s) | 2024-05-07 | PDF 113.7 KB |
| RF Exposure | RF Exposure Info | 2025-11-20 | PDF 227.5 KB |
| RF Exposure Report | RF Exposure Info | 2025-11-19 | PDF 227.5 KB |
| RF exposure report | RF Exposure Info | 2025-03-26 | PDF 227.5 KB |
| FCC RF Exposure-MPE | RF Exposure Info | 2024-07-03 | PDF 225.2 KB |
| BLOCK Metadata only | Block Diagram | PDF 277.3 KB | |
| Block Diagram Metadata only | Block Diagram | PDF 277.3 KB | |
| Block diagram Metadata only | Block Diagram | PDF 306.3 KB | |
| SCH Metadata only | Schematics | PDF 1.4 MB | |
| SCH Metadata only | Schematics | PDF 1.4 MB | |
| Schematic Metadata only | Schematics | PDF 2.1 MB | |
| Schematic_WIFI module Metadata only | Schematics | PDF 109.4 KB | |
| OPS Metadata only | Operational Description | PDF 182 KB | |
| OPS Metadata only | Operational Description | PDF 181.9 KB | |
| Operational Description Metadata only | Operational Description | PDF 107.5 KB |
Application Information
| Application ID | 5xJY0lSfulu9pV7cp3p6gw== |
|---|---|
| Final Action Date | 2025-11-20 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0034627448 |
| Model | S1N1PRO |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Robotic Pool Cleaner |
| Responsible Party | Ivy Xu, ivy.xu@aiper.com |
| Technical Contact | Shenzhen Aiper Intelligent Co.,Ltd., ivy.xu@aiper.com |
| Test Firm | Tracy Qi, Shenzhen CTL Testing Technology Co., Ltd., qihui@ctl-lab.com |
| TCB Email | anezam@qai.org |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| 5xJY0lSfulu9pV7cp3p6gw== | 2025-11-20 | Class II permissive change or modification of presently authorized equipment |
| qMD2ot8THamItgnlnfZFbw== | 2025-11-19 | Class II permissive change or modification of presently authorized equipment |
| DLLGQWJYugZz7JodG5kNMA== | 2025-03-26 | Class II permissive change or modification of presently authorized equipment |
| lBB5ZuO9EElzV+9Z4iemew== | 2024-07-03 | Class II permissive change or modification of presently authorized equipment |
| QtiO2ddUA+6FmklH+Hb+0g== | 2024-05-07 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application QtiO2ddUA+6FmklH+Hb+0g==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 05/07/2024 Application Dated: 05/07/2024 |
| Shenzhen Aiper Intelligent Co.,Ltd. |
| 32nd floor, Block C, Phase 2 Galaxy World |
| Minle community, Minzhi street, Longhua district |
| Shenzhen, China |
| Attention: Ivy Xu |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BD5N-S1N1PRO |
| Name of Grantee: | Shenzhen Aiper Intelligent Co.,Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Robotic Pool Cleaner |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0001 | |||
| 15C | 2412.0 - 2462.0 | 0.0167 |
| Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
EAS Grant - Application QtiO2ddUA+6FmklH+Hb+0g==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen Aiper Intelligent Co.,Ltd. 32nd floor, Block C, Phase 2 Galaxy World Minle community, Minzhi street, Longhua district Shenzhen, China |
Date of Grant: 05/07/2024 Application Dated: 05/07/2024 |
| Attention: Ivy Xu |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BD5N-S1N1PRO |
| Name of Grantee: | Shenzhen Aiper Intelligent Co.,Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Robotic Pool Cleaner |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0001 | |||
| 15C | 2412.0 - 2462.0 | 0.0167 |
| Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 11/19/2025 Application Dated: 11/19/2025 |
| Shenzhen Aiper Intelligent Co.,Ltd. |
| 32nd floor, Block C, Phase 2 Galaxy World |
| Minle community, Minzhi street, Longhua district |
| Shenzhen, China |
| Attention: Ivy Xu , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BD5N-S1N1PRO |
| Name of Grantee: | Shenzhen Aiper Intelligent Co.,Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Robotic Pool Cleaner |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0001 | |||
| 15C | 2412.0 - 2462.0 | 0.0167 |
| C2PC. The prototype is modified as follows: 1, Add two level filter in the garbage basket + change the structure in the figure below to fill in the red part. 2, A. Remove the TOF circuit (not used). B. Add charge switch MOS tube and slow start MOS tube. C. Remove the 154/433 circuit (not used) D. A set of charging shrapnel wire is added to the whole machine. 3, The shell has modified its structure. Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
TCB Grant - Application lBB5ZuO9EElzV+9Z4iemew==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Eurofins Product Service GmbH Storkower Strasse 38c D-15526 Reichenwalde, Germany |
Date of Grant: 07/03/2024 Application Dated: 07/03/2024 |
| Shenzhen Aiper Intelligent Co.,Ltd. |
| 32nd floor, Block C, Phase 2 Galaxy World |
| Minle community, Minzhi street, Longhua district |
| Shenzhen, China |
| Attention: Ivy Xu |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BD5N-S1N1PRO |
| Name of Grantee: | Shenzhen Aiper Intelligent Co.,Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Robotic Pool Cleaner |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0001 | |||
| 15C | 2412.0 - 2462.0 | 0.0167 |
| Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. C2PC as adding an accessory charging dock. |
EAS Grant - Application lBB5ZuO9EElzV+9Z4iemew==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Shenzhen Aiper Intelligent Co.,Ltd. 32nd floor, Block C, Phase 2 Galaxy World Minle community, Minzhi street, Longhua district Shenzhen, China |
Date of Grant: 07/03/2024 Application Dated: 07/03/2024 |
| Attention: Ivy Xu |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BD5N-S1N1PRO |
| Name of Grantee: | Shenzhen Aiper Intelligent Co.,Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Robotic Pool Cleaner |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0001 | |||
| 15C | 2412.0 - 2462.0 | 0.0167 |
| Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. C2PC as adding an accessory charging dock. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 03/26/2025 Application Dated: 03/26/2025 |
| Shenzhen Aiper Intelligent Co.,Ltd. |
| 32nd floor, Block C, Phase 2 Galaxy World |
| Minle community, Minzhi street, Longhua district |
| Shenzhen, China |
| Attention: Ivy Xu , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BD5N-S1N1PRO |
| Name of Grantee: | Shenzhen Aiper Intelligent Co.,Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Robotic Pool Cleaner |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0001 | |||
| 15C | 2412.0 - 2462.0 | 0.0167 |
| C2PC The prototype is modified as follows 1. Add two level filter in the garbage basket + change the structure in the figure below to fill in the red part. 2. A. Remove the TOF circuit (not used). B. Add charge switch MOS tube and slow start MOS tube. C. Remove the 154/433 circuit (not used) D. A set of charging shrapnel wire is added to the whole machine. 3. The shell has modified its structure. Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |
TCB Grant - Application 5xJY0lSfulu9pV7cp3p6gw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
QAI LABORATORIES LTD 3980 North Fraser Way Burnaby, BC, V5J5K5 Canada |
Date of Grant: 11/20/2025 Application Dated: 11/19/2025 |
| Shenzhen Aiper Intelligent Co.,Ltd. |
| 32nd floor, Block C, Phase 2 Galaxy World |
| Minle community, Minzhi street, Longhua district |
| Shenzhen, China |
| Attention: Ivy Xu , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BD5N-S1N1PRO |
| Name of Grantee: | Shenzhen Aiper Intelligent Co.,Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | Robotic Pool Cleaner |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15C | 2402.0 - 2480.0 | 0.0001 | |||
| 15C | 2412.0 - 2462.0 | 0.0167 |
| C2PC. The prototype is modified as follows: 1, Add two level filter in the garbage basket + change the structure in the figure below to fill in the red part. 2, A. Remove the TOF circuit (not used). B. Add charge switch MOS tube and slow start MOS tube. C. Remove the 154/433 circuit (not used) D. A set of charging shrapnel wire is added to the whole machine. 3, The shell has modified its structure. Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. |