FCC ID 2BEE6-SUP-WSR550

Radar level transmitter

by Hangzhou Supmea Automation Co.,Ltd.

Grantee Code: 2BEE6   Product Code: SUPWSR550
Latest application date: 2024-02-03

FCC ID Device Details

FCC ID2BEE6-SUP-WSR550
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BEE6
Product CodeSUPWSR550
Applicant BusinessHangzhou Supmea Automation Co.,Ltd. 🇨🇳
Equipment ClassRadar level transmitter
Test FirmShenzhen Tianhai Test Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
76000-79300 MHzOriginal Equipment2024-02-03

Exhibits

DocumentTypeAvailableFile
user manualUsers Manual2024-02-03PDF 2 MB
InternalphotoInternal Photos2024-02-03PDF 3 MB
ExternalphotoExternal Photos2024-02-03PDF 818.5 KB
label and locationID Label/Location Info2024-02-03PDF 185.6 KB
Test Setup PhotosTest Setup Photos2024-02-03PDF 354.4 KB
test ReportTest Report2024-02-03PDF 1.3 MB
USA agentAttestation Statements2024-02-03PDF 100.4 KB
cover letterAttestation Statements2024-02-03PDF 119 KB
ANT ReportCover Letter(s)2024-02-03PDF 420.2 KB
Agent Authorization Letter TemplatsCover Letter(s)2024-02-03PDF 141.1 KB
FCC Short & Long Term Confidentiality RequestCover Letter(s)2024-02-03PDF 59.6 KB
RF exposure reportRF Exposure Info2024-02-03PDF 255.6 KB
BLOK Metadata onlyBlock DiagramPDF 202.6 KB
SCH Metadata onlySchematicsPDF 1.3 MB
OPS Metadata onlyOperational DescriptionPDF 123.2 KB

Application Information

Application IDNAiAs5NE+j1K8p4pooKYjA==
Final Action Date2024-02-03
Application PurposeOriginal Equipment
Applicant FRN0034717488
ModelSUP-WSR550
Frequency Range76000-79300 MHz
Equipment ClassLPR - Level Probing Radar
Device DescriptionRadar level transmitter
Responsible PartyZhifang Zhou, zzfang8892316@163.com , +86 15068105756
Technical ContactHangzhou Supmea Automation Co.,Ltd., zzfang8892316@163.com
Test FirmBing Lee, Shenzhen Tianhai Test Technology Co., Ltd., binglee@tianhaitest.com , +86-755-8661 5100
TCB Emailanezam@qai.org
TCB ScopeA2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsThe power listed is peak EIRP calculated in 50MHz bandwidth. This device must be professionally installed. This device must be installed and maintained to ensure a vertically downward orientation of the transmit antenna's main beam. This device may only operate at fixed locations and may not operate while being moved, or while inside a moving container. Hand-held applications are prohibited. Hand-held applications are prohibited. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
NAiAs5NE+j1K8p4pooKYjA==2024-02-03Original Equipment

Equipment Authorization

FrequencyOutputRules
76000-79300 MHz0.770000015.256

Grants

TCB Grant - Application NAiAs5NE+j1K8p4pooKYjA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  QAI LABORATORIES LTD
3980 North Fraser Way
Burnaby, BC, V5J5K5
Canada
Date of Grant: 02/03/2024

Application Dated: 02/03/2024
Hangzhou Supmea Automation Co.,Ltd.
Room No.526, 5th floor, Building 4, Singapore
Hangzhou Science &Technology Park, Hangzhou, China
Hangzhou,
China
 
Attention: Zhifang Zhou

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BEE6-SUP-WSR550
Name of Grantee:  Hangzhou Supmea Automation Co.,Ltd.
Equipment Class: Level Probing Radar
Notes: Radar level transmitter
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15.256 76000.0  -  79300.0 0.77  

The power listed is peak EIRP calculated in 50MHz bandwidth. This device must be professionally installed. This device must be installed and maintained to ensure a vertically downward orientation of the transmit antenna's main beam. This device may only operate at fixed locations and may not operate while being moved, or while inside a moving container. Hand-held applications are prohibited. Hand-held applications are prohibited. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

EAS Grant - Application NAiAs5NE+j1K8p4pooKYjA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Hangzhou Supmea Automation Co.,Ltd.
Room No.526, 5th floor, Building 4, Singapore Hangzhou Science &Technology Park, Hangzhou, China
Hangzhou,
China
  Date of Grant: 02/03/2024

Application Dated: 02/03/2024
 
Attention: Zhifang Zhou

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BEE6-SUP-WSR550
Name of Grantee:  Hangzhou Supmea Automation Co.,Ltd.
Equipment Class: Level Probing Radar
Notes: Radar level transmitter
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15.256 76000.0  -  79300.0 0.77  

The power listed is peak EIRP calculated in 50MHz bandwidth. This device must be professionally installed. This device must be installed and maintained to ensure a vertically downward orientation of the transmit antenna's main beam. This device may only operate at fixed locations and may not operate while being moved, or while inside a moving container. Hand-held applications are prohibited. Hand-held applications are prohibited. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.



Mail To: