FCC ID 2BGHD-VTL202402

5G Mobile Phone

by Chengdu Xiaochen Technology Co., Ltd

Grantee Code: 2BGHD   Product Code: VTL202402
Latest application date: 2025-05-28

FCC ID Device Details

FCC ID2BGHD-VTL202402
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BGHD
Product CodeVTL202402
Applicant BusinessChengdu Xiaochen Technology Co., Ltd 🇨🇳
Related Domains sunateight.com
Equipment Class5G Mobile Phone
Test FirmCCIC Southern Testing Co., Ltd

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
701.5-713.5 MHzOriginal Equipment2025-05-28
13.56 MHzOriginal Equipment2025-05-28
5180-5240 MHzOriginal Equipment2025-05-28
2412-2462 MHzOriginal Equipment2025-05-28
2402-2480 MHzOriginal Equipment2025-05-28

Exhibits

DocumentTypeAvailableFile
User MannulUsers Manual2025-11-24PDF 997.2 KB
User ManualUsers Manual2025-11-24PDF 997.2 KB
User manualUsers Manual2025-11-24PDF 997.2 KB
Internal PhotosInternal Photos2025-11-24PDF 2.5 MB
Internal photosInternal Photos2025-11-24PDF 2.5 MB
External PhotosExternal Photos2025-11-24PDF 1.7 MB
External photosExternal Photos2025-11-24PDF 1.7 MB
Label & Label LocationID Label/Location Info2025-05-28PDF 1.9 MB
Label and LocationID Label/Location Info2025-05-28PDF 1.9 MB
Label and locationID Label/Location Info2025-05-28PDF 1.9 MB
15B Test setup V1.0Test Setup Photos2025-11-24PDF 1.4 MB
15C Test setup V1.0Test Setup Photos2025-11-24PDF 1.5 MB
DFS Test setupTest Setup Photos2025-11-24PDF 234.9 KB
NFC Test setupTest Setup Photos2025-11-24PDF 1.2 MB
Test Setup photo---PCETest Setup Photos2025-11-24PDF 953 KB
Test Setup photo---SARTest Setup Photos2025-11-24PDF 362.8 KB
2.4GWIFIReport.docx 1Test Report2025-05-28PDF 5.1 MB
2.4GWIFIReport.docx 2Test Report2025-05-28PDF 5.7 MB
2.4GWIFIReport.docx 3Test Report2025-05-28PDF 5.8 MB
Antenna SpecificationTest Report2025-05-28PDF 4.5 MB
Antenna specificationTest Report2025-05-28PDF 4.5 MB
BLE ReportTest Report2025-05-28PDF 3.5 MB
BT ReportTest Report2025-05-28PDF 3.5 MB
DFS reportTest Report2025-05-28PDF 2.2 MB
EMC ReportTest Report2025-05-28PDF 895 KB
FCC-LTEReport.docx 1Test Report2025-05-28PDF 5.4 MB
FCC-LTEReport.docx 2Test Report2025-05-28PDF 5.8 MB
FCC-LTEReport.docx 3Test Report2025-05-28PDF 5.7 MB
FCC-LTEReport.docx 4Test Report2025-05-28PDF 4.6 MB
FCC-LTEReport.docx 5Test Report2025-05-28PDF 1.9 MB
FCC-NRReport.docx 1Test Report2025-05-28PDF 5.7 MB
FCC-NRReport.docx 2Test Report2025-05-28PDF 5.3 MB
FCC-NRReport.docx 3Test Report2025-05-28PDF 5.3 MB
FCC-NRReport.docx 4Test Report2025-05-28PDF 5.3 MB
FCC-NRReport.docx 5Test Report2025-05-28PDF 5.1 MB
FCC-NRReport.docx 6Test Report2025-05-28PDF 2 MB
FCC-WIFI (5GHz band 1,2,3,4) Report -1Test Report2025-05-28PDF 3.8 MB
FCC-WIFI (5GHz band 1,2,3,4) Report -2Test Report2025-05-28PDF 4.6 MB
GSM WCDMA ReportTest Report2025-05-28PDF 3.8 MB
NFC Report V1.0Test Report2025-05-28PDF 994.7 KB
2.911 d 5 ii CertificiationApplicantv1.3Attestation Statements2025-05-28PDF 89.1 KB
2.911 (d)(5)(i)CertificationEquipmentTypev1.2Attestation Statements2025-05-28PDF 68 KB
2.911 (d)(5)(ii)CertificationApplicantv1.3Attestation Statements2025-05-28PDF 89.1 KB
2.911 (d)(5)(ii)CertificiationApplicantv1.2Attestation Statements2025-05-28PDF 89.1 KB
2.911 (d)(7) US AgentAttestation Statements2025-05-28PDF 103.4 KB
2.911 (d)(7)USAgentforServiceofProcessv1.3Attestation Statements2025-05-28PDF 103.4 KB
2.911 (d)(7)USAgentforServiceofProcessv1.4Attestation Statements2025-05-28PDF 103.4 KB
2.911_(d)(5)(ii) Certificiation Applicant v1.3Attestation Statements2025-05-28PDF 89.1 KB
2.911_(d)(7) US Agent for Service of Process v1.3Attestation Statements2025-05-28PDF 103.4 KB
AgentAuthorizationRev1.0Cover Letter(s)2025-05-28PDF 73.5 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2025-05-28PDF 54.5 KB
FCC Short & Long Term Confidentiality Request Rev4.1 ULCC52 497 8562925Cover Letter(s)2025-05-28PDF 54.5 KB
FCC Software Configuration Control DeclarationCover Letter(s)2025-05-28PDF 74.6 KB
Letter of AuthorizationCover Letter(s)2025-05-28PDF 73.5 KB
RF Exposure Report V1.0RF Exposure Info2025-05-28PDF 302.5 KB
SAR Calibration Report_Part 1RF Exposure Info2025-05-28PDF 5.4 MB
SAR Calibration Report_Part 2RF Exposure Info2025-05-28PDF 5.5 MB
SAR Calibration Report_Part 3RF Exposure Info2025-05-28PDF 5.2 MB
SAR Calibration Report_Part 4RF Exposure Info2025-05-28PDF 1.1 MB
SAR Calibration Report_Part 5RF Exposure Info2025-05-28PDF 4.8 MB
SAR Calibration Report_Part 6RF Exposure Info2025-05-28PDF 3.5 MB
SAR_Part 1 v1RF Exposure Info2025-05-28PDF 5 MB
SAR_Part 2 v1RF Exposure Info2025-05-28PDF 3.8 MB
Block Diagram Metadata onlyBlock DiagramPDF 136.1 KB
Block diagram Metadata onlyBlock DiagramPDF 136.1 KB
SCH Metadata onlySchematicsPDF 2.7 MB
OP Metadata onlyOperational DescriptionPDF 2.3 MB
NII Software Security Info Metadata onlySDR Software/Security Info.PDF 118.7 KB
BOM_MB V1 Metadata onlyParts List/Tune Up InfoPDF 94.6 KB
BOM_SB V1 Metadata onlyParts List/Tune Up InfoPDF 120.6 KB
Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 1.6 MB
Tune up procedure Metadata onlyParts List/Tune Up InfoPDF 1.6 MB

Application Information

Application IDwcYsI6NiIiraZ7nc7oyzbQ==
Final Action Date2025-05-28
Application PurposeOriginal Equipment
Applicant FRN0035439207
ModelVTL202402
Frequency Range701.5-713.5 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device Description5G Mobile Phone
Responsible PartyWan Zu, General Manager, zu.wan@sunateight.com , +86-028-69652420
Technical ContactChengdu Xiaochen Technology Co., Ltd, zu.wan@sunateight.com
Test FirmChris You, CCIC Southern Testing Co., Ltd, youxj@ccic-set.com , 86-0755-86131239
TCB Emailcertification@micomlabs.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityYes
Short-Term Confidentiality Date11/24/2025
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceYes
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn and simultaneous SAR accessory are 0.78 W/kg, 0.73 W/kg and 1.27 W/kg respectively.

Applications

Application IDDatePurpose
wcYsI6NiIiraZ7nc7oyzbQ==2025-05-28Original Equipment
oLENaWCIlE1V3PLYQ9e8TQ==2025-05-28Original Equipment
l4kfci2S/wT7s/jRNeKwSw==2025-05-28Original Equipment
BdrTPtBhc1P/2HEiWs0c3A==2025-05-28Original Equipment
/BOZ1SL4Ho8In+x2d0OEOg==2025-05-28Original Equipment
+w+2LfxQgTvJcjHkJ3/vNQ==2025-05-28Original Equipment

Equipment Authorization

FrequencyOutputToleranceGrant Notes
CC
13.56 MHzCC
701.5-713.5 MHz0.0870.004367ppm
704-711 MHz0.0850.004367ppm
704-711 MHz0.0690.004367ppm
706.5-713.5 MHz0.0850.004775ppm
709-711 MHz0.0840.004775ppm
709-711 MHz0.0680.004775ppm
815.5-822.5 MHz0.0880.003126ppm
815.5-822.5 MHz0.070.003126ppm
816.5-821.5 MHz0.0750.001685ppm
816.5-821.5 MHz0.060.001685ppm
819 MHz0.0850.003126ppm
819 MHz0.0690.003126ppm
819 MHz0.0780.001685ppm
819 MHz0.0730.001685ppm
819 MHz0.0550.001685ppm
825.5-847.5 MHz0.0890.010616ppm
826.5-846.5 MHz0.0710.010616ppm
826.5-846.5 MHz0.0870.004794ppm
826.5-846.5 MHz0.0720.004794ppm
826.5-846.5 MHz0.0770.008177ppm
826.5-846.5 MHz0.0640.008177ppm
829-844 MHz0.0880.010616ppm
829-844 MHz0.070.010616ppm
829-844 MHz0.0760.008057ppm
829-844 MHz0.0770.008057ppm
829-844 MHz0.060.008057ppm
829-844 MHz0.0740.008177ppm
829-844 MHz0.0730.008177ppm
829-844 MHz0.0610.008177ppm
831.5-841.5 MHz0.0860.004794ppm
831.5-841.5 MHz0.0690.004794ppm
831.5-841.5 MHz0.080.008057ppm
831.5-841.5 MHz0.0780.008057ppm
831.5-841.5 MHz0.0650.008057ppm
831.5-841.5 MHz0.0770.008177ppm
1711.5-1778.5 MHz0.20.00208ppm
1711.5-1778.5 MHz0.1660.00208ppm
1715-1750 MHz0.1990.0037ppm
1715-1750 MHz0.160.0037ppm
1715-1775 MHz0.1890.000946ppm
1717.5-1772.5 MHz0.1860.000946ppm
1717.5-1772.5 MHz0.1460.000946ppm
1720-1745 MHz0.1960.0037ppm
1720-1745 MHz0.1580.0037ppm
1720-1770 MHz0.1920.00208ppm
1720-1770 MHz0.1550.00208ppm
1720-1770 MHz0.1760.000946ppm
1720-1770 MHz0.1770.000946ppm
1720-1770 MHz0.1430.000946ppm
1852.5-1912.5 MHz0.2280.003665ppm
1852.5-1912.5 MHz0.190.003665ppm
1852.5-1912.5 MHz0.2040.005939ppm
1852.5-1912.5 MHz0.1580.005939ppm
1857.5-1902.5 MHz0.1630.003984ppm
1860-1905 MHz0.2190.003665ppm
1860-1905 MHz0.1710.003665ppm
1860-1900 MHz0.1950.003984ppm
1860-1900 MHz0.20.003984ppm
1860-1900 MHz0.1520.003984ppm
1860-1905 MHz0.2040.005939ppm
1860-1905 MHz0.2030.005939ppm
1860-1905 MHz0.1570.005939ppm
2402-2480 MHz0.0310000CC
2402-2480 MHz0.01CC
2412-2462 MHz0.081CC, MO
2498.5-2687.5 MHz0.2170.002626ppm
2498.5-2687.5 MHz0.1750.002626ppm
2501.5-2680 MHz0.2160.011424ppm
2502.5-2567.5 MHz0.1650.001645ppm
2505-2565 MHz0.130.002552ppm
2506-2680 MHz0.2130.002626ppm
2506-2680 MHz0.1730.002626ppm
2506-2686.7 MHz0.1780.011424ppm
2506.02-2679.99 MHz0.3410.003386ppm
2506.02-2679.99 MHz0.2640.003386ppm
2506.5-2680 MHz0.2140.011424ppm
2506.5-2680 MHz0.1730.011424ppm
2510-2560 MHz0.160.002552ppm
2510-2560 MHz0.1250.002552ppm
2510-2560 MHz0.1550.017251ppm
2510-2560 MHz0.1250.017251ppm
2510-2564.5 MHz0.160.017251ppm
2510-2562.2 MHz0.1340.017251ppm
2512.5-2557.5 MHz0.1320.001645ppm
2516.01-2670 MHz0.3430.003386ppm
2520-2550 MHz0.1610.001645ppm
2520-2550 MHz0.1570.001645ppm
2520-2550 MHz0.1240.001645ppm
2546.01-2640 MHz0.3240.003386ppm
2546.01-2640 MHz0.2620.003386ppm
3475.02-3525 MHz0.3930.00332ppm
3475.02-3525 MHz0.3850.00332ppm
3475.02-3525 MHz0.390.001946ppm
3495-3504.99 MHz0.3080.00332ppm
3495-3504.99 MHz0.3070.001946ppm
3500.01 MHz0.3810.00332ppm
3500.01 MHz0.3780.00332ppm

Grants

TCB Grant - Application wcYsI6NiIiraZ7nc7oyzbQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 05/28/2025

Application Dated: 05/28/2025
Chengdu Xiaochen Technology Co., Ltd
3rd Floor, Building B15, Ganzhizhongguo Chengdu
Center, No. 777 Huafu Avenue Shuangliu County,
Chengdu City,,
China
 
Attention: Wan Zu , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BGHD-VTL202402
Name of Grantee:  Chengdu Xiaochen Technology Co., Ltd
Equipment Class: PCS Licensed Transmitter held to ear
Notes: 5G Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.2  -  848.8 0.495 0.020536  PM 247KGXW
22H 824.2  -  848.8 0.134 0.028676  PM 245KG7W
22H 826.4  -  846.6 0.078 0.000406  PM 4M14F9W
24E 1850.2  -  1909.8 0.612 0.002904  PM 245KGXW
24E 1850.2  -  1909.8 0.174 0.007351  PM 245KG7W
24E 1852.4  -  1907.6 0.2 0.000995  PM 4M15F9W
27 1712.4  -  1852.6 0.175 0.00232  PM 4M15F9W
24E 1860.0  -  1900.0 0.215 0.004255  PM 17M9G7D
24E 1860.0  -  1900.0 0.171 0.004255  PM 17M9W7D
24E 1851.5  -  1908.5 0.217 0.004255  PM 2M69G7D
24E 1857.5  -  1902.5 0.173 0.004255  PM 13M5W7D
27 1720.0  -  1745.0 0.196 0.0037  PM 18M0G7D
27 1720.0  -  1745.0 0.158 0.0037  PM 17M9W7D
27 1715.0  -  1750.0 0.199 0.0037  PM 8M95G7D
27 1715.0  -  1750.0 0.16 0.0037  PM 8M96W7D
27 2510.0  -  2560.0 0.16 0.002552  PM 17M9G7D
27 2510.0  -  2560.0 0.125 0.002552  PM 17M9W7D
27 2505.0  -  2565.0 0.13 0.002552  PM 8M95W7D
24E 1860.0  -  1905.0 0.219 0.003665  PM 18M0G7D
24E 1860.0  -  1905.0 0.171 0.003665  PM 17M9W7D
24E 1852.5  -  1912.5 0.228 0.003665  PM 4M52G7D
24E 1852.5  -  1912.5 0.19 0.003665  PM 4M52W7D
27 2506.0  -  2680.0 0.213 0.002626  PM 17M9G7D
27 2506.0  -  2680.0 0.173 0.002626  PM 17M9W7D
27 2498.5  -  2687.5 0.217 0.002626  PM 4M52G7D
27 2498.5  -  2687.5 0.175 0.002626  PM 4M52W7D
27 1720.0  -  1770.0 0.192 0.00208  PM 17M9G7D
27 1720.0  -  1770.0 0.155 0.00208  PM 18M0W7D
27 1711.5  -  1778.5 0.2 0.00208  PM 2M69G7D
27 1711.5  -  1778.5 0.166 0.00208  PM 2M69W7D
27 2510.0  -  2560.0 0.155 0.017251  PM 37M7G7D
27 2510.0  -  2560.0 0.125 0.017251  PM 37M7W7D
27 2510.0  -  2564.5 0.16 0.017251  PM 27M9G7D
27 2510.0  -  2562.2 0.134 0.017251  PM 32M7W7D
27 2506.5  -  2680.0 0.214 0.011424  PM 37M8G7D
27 2506.5  -  2680.0 0.173 0.011424  PM 37M8W7D
27 2501.5  -  2680.0 0.216 0.011424  PM 27M8G7D
27 2506.0  -  2686.7 0.178 0.011424  PM 23M0W7D
22H 829.0  -  844.0 0.088 0.010616  PM 8M96G7D
22H 829.0  -  844.0 0.07 0.010616  PM 8M96W7D
22H 825.5  -  847.5 0.089 0.010616  PM 2M69G7D
22H 826.5  -  846.5 0.071 0.010616  PM 4M52W7D
27 704.0  -  711.0 0.085 0.004367  PM 8M94G7D
27 704.0  -  711.0 0.069 0.004367  PM 8M96W7D
27 701.5  -  713.5 0.087 0.004367  PM 4M52G7D
27 709.0  -  711.0 0.084 0.004775  PM 8M94G7D
27 709.0  -  711.0 0.068 0.004775  PM 8M95W7D
27 706.5  -  713.5 0.085 0.004775  PM 4M52G7D
22H 831.5  -  841.5 0.086 0.004794  PM 13M5G7D
22H 831.5  -  841.5 0.069 0.004794  PM 13M5W7D
22H 826.5  -  846.5 0.087 0.004794  PM 4M53G7D
22H 826.5  -  846.5 0.072 0.004794  PM 4M51W7D
90 819.0  -  819.0 0.085 0.003126  PM 8M93G7D
90 819.0  -  819.0 0.069 0.003126  PM 8M95W7D
90 815.5  -  822.5 0.088 0.003126  PM 2M69G7D
90 815.5  -  822.5 0.07 0.003126  PM 2M68W7D
24E 1860.0  -  1900.0 0.195 0.003984  PM 17M8G7D
24E 1860.0  -  1900.0 0.2 0.003984  PM 17M9G7D
24E 1860.0  -  1900.0 0.152 0.003984  PM 17M9W7D
24E 1857.5  -  1902.5 0.163 0.003984  PM 13M4W7D
22H 829.0  -  844.0 0.076 0.008057  PM 17M9G7D
22H 829.0  -  844.0 0.077 0.008057  PM 17M9G7D
22H 829.0  -  844.0 0.06 0.008057  PM 17M9W7D
22H 831.5  -  841.5 0.08 0.008057  PM 13M4G7D
22H 831.5  -  841.5 0.078 0.008057  PM 13M4G7D
22H 831.5  -  841.5 0.065 0.008057  PM 13M4W7D
27 2520.0  -  2550.0 0.161 0.001645  PM 38M5G7D
27 2520.0  -  2550.0 0.157 0.001645  PM 38M5G7D
27 2520.0  -  2550.0 0.124 0.001645  PM 38M5W7D
27 2502.5  -  2567.5 0.165 0.001645  PM 4M47G7D
27 2512.5  -  2557.5 0.132 0.001645  PM 22M8W7D
24E 1860.0  -  1905.0 0.204 0.005939  PM 17M8G7D
24E 1860.0  -  1905.0 0.203 0.005939  PM 17M8G7D
24E 1860.0  -  1905.0 0.157 0.005939  PM 17M8W7D
24E 1852.5  -  1912.5 0.204 0.005939  PM 4M48G7D
24E 1852.5  -  1912.5 0.158 0.005939  PM 4M48W7D
90 819.0  -  819.0 0.078 0.001685  PM 8M92G7D
90 819.0  -  819.0 0.073 0.001685  PM 8M91G7D
90 819.0  -  819.0 0.055 0.001685  PM 8M95W7D
90 816.5  -  821.5 0.075 0.001685  PM 4M48G7D
90 816.5  -  821.5 0.06 0.001685  PM 4M47W7D
22H 829.0  -  844.0 0.074 0.008177  PM 17M9G7D
22H 829.0  -  844.0 0.073 0.008177  PM 17M9G7D
22H 829.0  -  844.0 0.061 0.008177  PM 17M9W7D
22H 826.5  -  846.5 0.077 0.008177  PM 4M48G7D
22H 831.5  -  841.5 0.077 0.008177  PM 13M4G7D
22H 826.5  -  846.5 0.064 0.008177  PM 4M48W7D
27 1720.0  -  1770.0 0.176 0.000946  PM 17M8G7D
27 1720.0  -  1770.0 0.177 0.000946  PM 17M8G7D
27 1720.0  -  1770.0 0.143 0.000946  PM 17M8W7D
27 1717.5  -  1772.5 0.186 0.000946  PM 13M4G7D
27 1715.0  -  1775.0 0.189 0.000946  PM 8M95G7D
27 1717.5  -  1772.5 0.146 0.000946  PM 13M4W7D
27 2546.01  -  2640.0 0.324 0.003386  PM 96M6G7D
27 2546.01  -  2640.0 0.324 0.003386  PM 96M8G7D
27 2546.01  -  2640.0 0.262 0.003386  PM 96M7W7D
27 2516.01  -  2670.0 0.343 0.003386  PM 35M7G7D
27 2506.02  -  2679.99 0.341 0.003386  PM 8M60G7D
27 2506.02  -  2679.99 0.264 0.003386  PM 8M59W7D
27 3500.01  -  3500.01 0.381 0.00332  PM 96M3G7D
27 3500.01  -  3500.01 0.378 0.00332  PM 96M6G7D
27 3500.01  -  3500.01 0.289 0.00332  PM 96M4W7D
27 3475.02  -  3525.0 0.393 0.00332  PM 45M7G7D
27 3475.02  -  3525.0 0.385 0.00332  PM 45M7G7D
27 3495.0  -  3504.99 0.308 0.00332  PM 86M6W7D
27 3500.01  -  3500.01 0.383 0.001946  PM 96M3G7D
27 3500.01  -  3500.01 0.385 0.001946  PM 96M6G7D
27 3500.01  -  3500.01 0.29 0.001946  PM 96M4W7D
27 3475.02  -  3525.0 0.39 0.001946  PM 45M5G7D
27 3495.0  -  3504.99 0.307 0.001946  PM 86M7W7D

Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn and simultaneous SAR accessory are 0.78 W/kg, 0.73 W/kg and 1.27 W/kg respectively.

TCB Grant - Application oLENaWCIlE1V3PLYQ9e8TQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 05/28/2025

Application Dated: 05/28/2025
Chengdu Xiaochen Technology Co., Ltd
3rd Floor, Building B15, Ganzhizhongguo Chengdu
Center, No. 777 Huafu Avenue Shuangliu County,
Chengdu City,,
China
 
Attention: Wan Zu , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BGHD-VTL202402
Name of Grantee:  Chengdu Xiaochen Technology Co., Ltd
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: 5G Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application l4kfci2S/wT7s/jRNeKwSw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 05/28/2025

Application Dated: 05/28/2025
Chengdu Xiaochen Technology Co., Ltd
3rd Floor, Building B15, Ganzhizhongguo Chengdu
Center, No. 777 Huafu Avenue Shuangliu County,
Chengdu City,,
China
 
Attention: Wan Zu , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BGHD-VTL202402
Name of Grantee:  Chengdu Xiaochen Technology Co., Ltd
Equipment Class: Unlicensed National Information Infrastructure TX
Notes: 5G Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC MO 15E 5180.0  -  5240.0 0.052  
CC MO ND 15E 5260.0  -  5320.0 0.068  
CC MO ND 15E 5500.0  -  5700.0 0.069  
CC MO 15E 5745.0  -  5825.0 0.052  

Output power listed is maximum combined conducted power. This device contains 20, 40, 80 and 160 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn and simultaneous SAR accessory are 0.32 W/kg, 0.34 W/kg and 1.27 W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.
ND: This UNII device complies with the Transmit Power Control (TPC) and Dynamic Frequency Selection (DFS) requirements in Section 15.407(h).

TCB Grant - Application BdrTPtBhc1P/2HEiWs0c3A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 05/28/2025

Application Dated: 05/28/2025
Chengdu Xiaochen Technology Co., Ltd
3rd Floor, Building B15, Ganzhizhongguo Chengdu
Center, No. 777 Huafu Avenue Shuangliu County,
Chengdu City,,
China
 
Attention: Wan Zu , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BGHD-VTL202402
Name of Grantee:  Chengdu Xiaochen Technology Co., Ltd
Equipment Class: Digital Transmission System
Notes: 5G Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.01  
CC MO 15C 2412.0  -  2462.0 0.081  

Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn and simultaneous SAR accessory are 0.17 W/kg, 0.16 W/kg and 1.27 W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

TCB Grant - Application /BOZ1SL4Ho8In+x2d0OEOg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 05/28/2025

Application Dated: 05/28/2025
Chengdu Xiaochen Technology Co., Ltd
3rd Floor, Building B15, Ganzhizhongguo Chengdu
Center, No. 777 Huafu Avenue Shuangliu County,
Chengdu City,,
China
 
Attention: Wan Zu , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BGHD-VTL202402
Name of Grantee:  Chengdu Xiaochen Technology Co., Ltd
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: 5G Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.031  

Power listed is the maximum conducted output power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn and simultaneous SAR accessory are 0.04 W/kg, 0.03 W/kg and 1.27 W/kg respectively.

CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application +w+2LfxQgTvJcjHkJ3/vNQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 05/28/2025

Application Dated: 05/28/2025
Chengdu Xiaochen Technology Co., Ltd
3rd Floor, Building B15, Ganzhizhongguo Chengdu
Center, No. 777 Huafu Avenue Shuangliu County,
Chengdu City,,
China
 
Attention: Wan Zu , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BGHD-VTL202402
Name of Grantee:  Chengdu Xiaochen Technology Co., Ltd
Equipment Class: Part 15 Class B Computing Device Peripheral
Notes: 5G Mobile Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.