FCC ID 2BGNB-PAM3

Personal Alcohol Monitoring System

by 1 A Lifesafer, Inc.

Grantee Code: 2BGNB   Product Code: PAM3
Latest application date: 2025-12-05

FCC ID Device Details

FCC ID2BGNB-PAM3
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BGNB
Product CodePAM3
Applicant Business1 A Lifesafer, Inc. 🇺🇸
Related Domains scramsystems.com
Equipment ClassPersonal Alcohol Monitoring System
Test FirmEUROFINS ELECTRICAL AND ELECTRONIC TESTING NA, INC

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1875.5-1902.5 MHzOriginal Equipment2025-12-05

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2025-12-05PDF 440.1 KB
Internal PhotosInternal Photos2025-12-05PDF 1,016 KB
External PhotosExternal Photos2025-12-05PDF 328 KB
LabelID Label/Location Info2025-12-05PDF 342.5 KB
Label IIID Label/Location Info2025-12-05PDF 151 KB
Test Setup PhotosTest Setup Photos2025-12-05PDF 717.9 KB
Antenna InfoTest Report2025-12-05PDF 1.2 MB
Test ReportTest Report2025-12-05PDF 1.8 MB
Test Report IITest Report2025-12-05PDF 5.5 MB
Test Report III Part 1Test Report2025-12-05PDF 1.5 MB
Test Report III Part 2Test Report2025-12-05PDF 3.6 MB
Test Report III Part 3Test Report2025-12-05PDF 3.8 MB
Test Report III Part 4Test Report2025-12-05PDF 3.6 MB
Test Report III Part 5Test Report2025-12-05PDF 3.3 MB
Test Report III Part 6Test Report2025-12-05PDF 3.1 MB
Test Report III Part 7Test Report2025-12-05PDF 3.3 MB
Test Report III Part 8Test Report2025-12-05PDF 3.8 MB
Test Report III Part 9Test Report2025-12-05PDF 188.6 KB
Covered Equipment AttestationAttestation Statements2025-12-05PDF 123.9 KB
Test Data Attestation LetterCover Letter(s)2025-12-05PDF 830.2 KB
US Agent for Service of ProcessAttestation Statements2025-12-05PDF 153.3 KB
Confidentiality LetterCover Letter(s)2025-12-05PDF 170.7 KB
RF Exposure ReportRF Exposure Info2025-12-05PDF 5.4 MB
Block Diagram Metadata onlyBlock DiagramPDF 95.4 KB
Schematics Metadata onlySchematicsPDF 1.8 MB
Operational Description Metadata onlyOperational DescriptionPDF 55.6 KB
Parts List I Metadata onlyParts List/Tune Up InfoPDF 233.8 KB
Parts List II Metadata onlyParts List/Tune Up InfoPDF 113.6 KB
Parts List III Metadata onlyParts List/Tune Up InfoPDF 113.6 KB

Application Information

Application IDUV1cU1l2YnPprjVGRE2DkQ==
Final Action Date2025-12-05
Application PurposeOriginal Equipment
Applicant FRN0035468834
ModelPAM3
Frequency Range1875.5-1902.5 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionPersonal Alcohol Monitoring System
Responsible PartyLouis Kevin Urani, lurani@scramsystems.com , 7243660372
Test FirmLauren Taylor, EUROFINS ELECTRICAL AND ELECTRONIC TESTING NA, INC, EENAquality@cpt.eurofinsus.com , 762-435-1689
TCB EmailTCB@nemko.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
UV1cU1l2YnPprjVGRE2DkQ==2025-12-05Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
824-849 MHz0.32651.0 PM4M14G7W22H
824.7-848.3 MHz0.30341.0 PM1M09G7D22H
825.5-847.5 MHz0.30261.0 PM2M69G7D22H
826.5-846.5 MHz0.23381.0 PM4M48D7W22H
829-844 MHz0.323591.0 PM8M94G7D22H
829-844 MHz0.23381.0 PM8M93D7W22H
1710-1755 MHz0.3235941.0 PM4M14G7W27
1712.5-1752.5 MHz0.287741.0 PM4M47G7D27
1717.5-1747.5 MHz0.268531.0 PM13M4D7W27
1720-1745 MHz0.265461.0 PM17M8G7D27
1720-1745 MHz0.211841.0 PM17M8D7W27
699.7-715.3 MHz0.297851.0 PM1M09G7D27
699.7-715.3 MHz0.219281.0 PM1M10D7W27
704-711 MHz0.258821.0 PM8M94G7D27
704-711 MHz0.214781.0 PM8M94D7W27
779.5-784.5 MHz0.313331.0 PM4M46G7D27
779.5-784.5 MHz0.238231.0 PM4M46D7W27
782 MHz0.28511.0 PM8M90G7D27
782 MHz0.223361.0 PM8M91D7W27
1711.5-1778.5 MHz0.276061.0 PM2M69G7D27
1711.5-1778.5 MHz0.223871.0 PM2M69D7W27
1720-1770 MHz0.271641.0 PM17M8G7D27
1720-1770 MHz0.223361.0 PM17M8D7W27
665.5-695.5 MHz0.251191.0 PM4M46G7D27
665.5-695.5 MHz0.210861.0 PM4M47D7W27
673-688 MHz0.234421.0 PM17M7G7D27
673-688 MHz0.182811.0 PM17M7D7W27
1850-1910 MHz0.2978521.0 PM4M14G7W24E
1850.7-1909.3 MHz0.27351.0 PM1M10G7D24E
1851.5-1908.5 MHz0.286421.0 PM2M69G7D24E
1852.5-1907.5 MHz0.236591.0 PM4M48G7D24E
1855-1905 MHz0.27661.0 PM8M93G7D24E
1875.5-1902.5 MHz0.24391.0 PM13M4G7D24E
1860-1900 MHz0.261821.0 PM17M8G7D24E
1860-1900 MHz0.229091.0 PM17M8D7W24E
790.5 MHz0.27411.0 PM4M47G7D90
793 MHz0.274161.0 PM8M90G7D90
793 MHz0.214291.0 PM8M91D7W90

Grants

TCB Grant - Application UV1cU1l2YnPprjVGRE2DkQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Nemko North America, Inc.
303 River Road
Ottawa, Ontario, K1V 1H2
Canada
Date of Grant: 12/05/2025

Application Dated: 12/04/2025
1 A Lifesafer, Inc.
3630 Park 42 Drive
Suite 140C
Cincinnati, OH 45241
 
Attention: Louis Urani , Director of Engineering

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BGNB-PAM3
Name of Grantee:  1 A Lifesafer, Inc.
Equipment Class: PCS Licensed Transmitter
Notes: Personal Alcohol Monitoring System
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
22H 824.0  -  849.0 0.3265 1.0  PM 4M14G7W
22H 824.7  -  848.3 0.3034 1.0  PM 1M09G7D
22H 825.5  -  847.5 0.3026 1.0  PM 2M69G7D
22H 826.5  -  846.5 0.2338 1.0  PM 4M48D7W
22H 829.0  -  844.0 0.32359 1.0  PM 8M94G7D
22H 829.0  -  844.0 0.2338 1.0  PM 8M93D7W
27 1710.0  -  1755.0 0.323594 1.0  PM 4M14G7W
27 1712.5  -  1752.5 0.28774 1.0  PM 4M47G7D
27 1717.5  -  1747.5 0.26853 1.0  PM 13M4D7W
27 1720.0  -  1745.0 0.26546 1.0  PM 17M8G7D
27 1720.0  -  1745.0 0.21184 1.0  PM 17M8D7W
27 699.7  -  715.3 0.29785 1.0  PM 1M09G7D
27 699.7  -  715.3 0.21928 1.0  PM 1M10D7W
27 704.0  -  711.0 0.25882 1.0  PM 8M94G7D
27 704.0  -  711.0 0.21478 1.0  PM 8M94D7W
27 779.5  -  784.5 0.31333 1.0  PM 4M46G7D
27 779.5  -  784.5 0.23823 1.0  PM 4M46D7W
27 782.0  -  782.0 0.2851 1.0  PM 8M90G7D
27 782.0  -  782.0 0.22336 1.0  PM 8M91D7W
27 1711.5  -  1778.5 0.27606 1.0  PM 2M69G7D
27 1711.5  -  1778.5 0.22387 1.0  PM 2M69D7W
27 1720.0  -  1770.0 0.27164 1.0  PM 17M8G7D
27 1720.0  -  1770.0 0.22336 1.0  PM 17M8D7W
27 665.5  -  695.5 0.25119 1.0  PM 4M46G7D
27 665.5  -  695.5 0.21086 1.0  PM 4M47D7W
27 673.0  -  688.0 0.23442 1.0  PM 17M7G7D
27 673.0  -  688.0 0.18281 1.0  PM 17M7D7W
24E 1850.0  -  1910.0 0.297852 1.0  PM 4M14G7W
24E 1850.7  -  1909.3 0.2735 1.0  PM 1M10G7D
24E 1851.5  -  1908.5 0.28642 1.0  PM 2M69G7D
24E 1852.5  -  1907.5 0.23659 1.0  PM 4M48G7D
24E 1855.0  -  1905.0 0.2766 1.0  PM 8M93G7D
24E 1875.5  -  1902.5 0.2439 1.0  PM 13M4G7D
24E 1860.0  -  1900.0 0.26182 1.0  PM 17M8G7D
24E 1860.0  -  1900.0 0.22909 1.0  PM 17M8D7W
90 790.5  -  790.5 0.2741 1.0  PM 4M47G7D
90 793.0  -  793.0 0.27416 1.0  PM 8M90G7D
90 793.0  -  793.0 0.21429 1.0  PM 8M91D7W

Output power listed is conducted. This device contains functions that are not operational in U.S. Territories. This filing is only applicable for U.S. operations.