FCC ID 2BL6A-WMDL

Smart Power Meter Clamp

by Shenzhen Wilmore Weiye Technology Co., Ltd.

Grantee Code: 2BL6A   Product Code: WMDL
Latest application date: 2024-11-21

FCC ID Device Details

FCC ID2BL6A-WMDL
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BL6A
Product CodeWMDL
Applicant BusinessShenzhen Wilmore Weiye Technology Co., Ltd. 🇨🇳
Equipment ClassSmart Power Meter Clamp
Test FirmShenzhen HUAK Testing Technology Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2024-11-21

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2025-05-21PDF 1.5 MB
Internal PhotoInternal Photos2025-05-21PDF 2.7 MB
External PhotosExternal Photos2025-05-21PDF 3.2 MB
Label LocationID Label/Location Info2024-11-21PDF 131.5 KB
Test photosTest Setup Photos2025-05-21PDF 636.3 KB
Antenna SpecificationTest Report2024-11-21PDF 797.1 KB
FCCID15.247TestReport-2.4gWiFi 1Test Report2024-11-21PDF 2.9 MB
FCCID15.247TestReport-2.4gWiFi 2Test Report2024-11-21PDF 3.6 MB
2.911 (d)(5)(i) Certification Equipment Type v1.2Attestation Statements2024-11-21PDF 870.2 KB
2.911 (d)(5)(ii) Certificiation Applicant v1.3Attestation Statements2024-11-21PDF 909.7 KB
2.911 (d)(7) US Agent for Service of Process v1.4Attestation Statements2024-11-21PDF 1.2 MB
2.911 (d)(7) US Agent for Service of Process v1.4Attestation Statements2024-11-21PDF 1.2 MB
Agent Authorization Rev 1.0Cover Letter(s)2024-11-21PDF 709.7 KB
FCC Short & Long Term Confidentiality Request Rev4.1Cover Letter(s)2024-11-21PDF 1 MB
Model Difference DeclarationCover Letter(s)2024-11-21PDF 444.8 KB
MPERF Exposure Info2024-11-21PDF 12.9 KB
Block diagram Metadata onlyBlock DiagramPDF 90.4 KB
SCH Metadata onlySchematicsPDF 85.3 KB
OP Metadata onlyOperational DescriptionPDF 28.1 KB

Application Information

Application IDOkS0Z/x9w0IgHhv/gEb8Yw==
Final Action Date2024-11-21
Application PurposeOriginal Equipment
Applicant FRN0036266344
ModelWMDL
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionSmart Power Meter Clamp
Responsible PartyLiu Hui, 877879448@qq.com , 18664356381
Technical ContactShenzhen Wilmore Weiye Technology Co., Ltd., 877879448@qq.com
Test FirmJason Zhou, Shenzhen HUAK Testing Technology Co., Ltd., jason@cer-mark.com , 86-755-23029901
TCB Emailcertification@micomlabs.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date05/21/2025
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
OkS0Z/x9w0IgHhv/gEb8Yw==2024-11-21Original Equipment

Equipment Authorization

FrequencyOutputRules
2412-2462 MHz0.017220015C

Grants

TCB Grant - Application OkS0Z/x9w0IgHhv/gEb8Yw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  MiCOM Labs
575 Boulder Court
Pleasanton, CA 94566
Date of Grant: 11/21/2024

Application Dated: 11/21/2024
Shenzhen Wilmore Weiye Technology Co., Ltd.
608, Building 4, Tongkangfu Industrial Zone
Yingrenshi Community, Shiyan Street
Baoan District, Shenzhen,
China
 
Attention: Liu Hui

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BL6A-WMDL
Name of Grantee:  Shenzhen Wilmore Weiye Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Smart Power Meter Clamp
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.01722  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.

EAS Grant - Application OkS0Z/x9w0IgHhv/gEb8Yw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Shenzhen Wilmore Weiye Technology Co., Ltd.
608, Building 4, Tongkangfu Industrial Zone Yingrenshi Community, Shiyan Street
Baoan District, Shenzhen,
China
  Date of Grant: 11/21/2024

Application Dated: 11/21/2024
 
Attention: Liu Hui

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BL6A-WMDL
Name of Grantee:  Shenzhen Wilmore Weiye Technology Co., Ltd.
Equipment Class: Digital Transmission System
Notes: Smart Power Meter Clamp
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.01722  

Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. The antenna used with this transmitter must be installed to provide a minimum separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi- transmitter product procedures. End-users must be provided with operating procedures for satisfying RF exposure compliance.



Mail To: