FCC ID 2BLGT-AGILSC250WIFI
5GSC-250-WIFI
by ST Engineering Advanced Networks & Sensors Pte. Ltd.
Grantee Code: 2BLGT Product Code: AGILSC250WIFI
Latest application date: 2025-04-02
FCC ID Device Details
| FCC ID | 2BLGT-AGILSC250WIFI |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2BLGT |
| Product Code | AGILSC250WIFI |
| Applicant Business | ST Engineering Advanced Networks & Sensors Pte. Ltd. 🇸🇬 |
| Related Domains | |
| Equipment Class | 5GSC-250-WIFI |
| Test Firm | Compliance Certification Services (Kunshan) Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 3600-3649.98 MHz | Change in identification of presently authorized equipment. Original FCC ID: ROR2002 Grant Date: 03/17/2025 | 2025-04-02 |
| 3459.99-3540 MHz | Change in identification of presently authorized equipment. Original FCC ID: ROR2002 Grant Date: 03/17/2025 | 2025-04-02 |
| 5180-5240 MHz | Change in identification of presently authorized equipment. Original FCC ID: ROR2002 Grant Date: 03/17/2025 | 2025-04-01 |
| 5955-7095 MHz | Change in identification of presently authorized equipment. Original FCC ID: ROR2002 Grant Date: 03/17/2025 | 2025-04-01 |
| 2412-2462 MHz | Change in identification of presently authorized equipment. Original FCC ID: ROR2002 Grant Date: 03/17/2025 | 2025-04-01 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2025-09-29 | PDF 2.7 MB |
| External photo | External Photos | 2025-09-29 | PDF 420.1 KB |
| Label | ID Label/Location Info | 2025-04-02 | PDF 333.5 KB |
| FCC_U.S. agent Letter | Attestation Statements | 2025-04-02 | PDF 262.2 KB |
| QSF27-14-04_Rev1.0_Applicant_Declaration_Letter | Attestation Statements | 2025-04-02 | PDF 295.8 KB |
| Auth letter | Cover Letter(s) | 2025-04-02 | PDF 277.3 KB |
| Confidentiality Leter | Cover Letter(s) | 2025-04-02 | PDF 274.6 KB |
| FCC Change ID-Cover Letter 1_by orignal application | Cover Letter(s) | 2025-04-02 | PDF 106.5 KB |
| FCC Change ID-Cover Letter 2_by new application | Cover Letter(s) | 2025-04-02 | PDF 275.5 KB |
| MPE Metadata only | RF Exposure Info | 2025-04-02 | PDF 449.4 KB |
Application Information
| Application ID | bd8ZsJVHyGcQIgZuZ400nQ== |
|---|---|
| Final Action Date | 2025-04-02 |
| Application Purpose | Change in identification of presently authorized equipment. Original FCC ID: ROR2002 Grant Date: 03/17/2025 |
| Applicant FRN | 0035996958 |
| Model | AGILSC250WIFI |
| Frequency Range | 3600-3649.98 MHz |
| Equipment Class | CBD - Citizens Band Category A and B Devices |
| Device Description | 5GSC-250-WIFI |
| Responsible Party | Hua Chong Lim, huachong.lim@stengg.com |
| Agent | Parlam Parlam Parlam, SGS-CSTC Standards Technical Services Co., Ltd., Parlam.zhan@sgs.com |
| Technical Contact | Parlam Zhan, SGS-CSTC Standards Technical Services Co., Ltd., Parlam.zhan@sgs.com |
| Non-Technical Contact | Parlam Zhan, SGS-CSTC Standards Technical Services Co., Ltd., Parlam.zhan@sgs.com |
| Test Firm | Jessica Chen, Compliance Certification Services (Kunshan) Inc., Jessica.chen1@sgs.com |
| TCB Email | USCTS.TCB@SGS.COM |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 09/29/2025 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is EIRP per antenna port. This device must be installed to provide a separation distance of at least 41 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. This device supports single carrier 10, 20, 30, 40, 60 and 100 MHz bandwidth, and CA_2CC: 10+10, 20+20, 30+10, 30+20, 40+20, 40+40, 60+20, CA_3CC: 10+10+10, 20+20+20, 40+20+10, 40+30+20, 40+20+20, CA_4CC: 40+30+20+10, 20+20+20+20 MHz bandwidth for 5G NR n48, n77, n78. Installers and end-users must be provided with installation instructions and transmitter operating conditions and instructions for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| bd8ZsJVHyGcQIgZuZ400nQ== | 2025-04-02 | Change in identification of presently authorized equipment. Original FCC ID: ROR2002 Grant Date: 03/17/2025 |
| BcMQ/WT+QVhVWhwktbYJXQ== | 2025-04-02 | Change in identification of presently authorized equipment. Original FCC ID: ROR2002 Grant Date: 03/17/2025 |
| pCvrWul53qeuwz6RuC9vZg== | 2025-04-01 | Change in identification of presently authorized equipment. Original FCC ID: ROR2002 Grant Date: 03/17/2025 |
| n9znlRclX4mvx8+ciQc3Dg== | 2025-04-01 | Change in identification of presently authorized equipment. Original FCC ID: ROR2002 Grant Date: 03/17/2025 |
| V5WjKRiDKwJwdSJDnrOXrg== | 2025-04-01 | Change in identification of presently authorized equipment. Original FCC ID: ROR2002 Grant Date: 03/17/2025 |
Equipment Authorization
| Frequency | Output | Tolerance | Grant Notes |
|---|---|---|---|
| 2412-2462 MHz | 0.326 | CC, MO | |
| 2422-2452 MHz | 0.308 | CC, MO | |
| 3459.99-3540 MHz | 0.998 | 2.5ppm | EP, MO |
| 3470.01-3544.98 MHz | 0.891 | 2.5ppm | EP, MO |
| 3499.98 MHz | 0.838 | 2.5ppm | EP, MO |
| 3565.02-3684.99 MHz | 0.991 | 2.5ppm | EP, MO |
| 3570-3694.98 MHz | 0.869 | 2.5ppm | EP, MO |
| 3600-3649.98 MHz | 0.984 | 2.5ppm | EP, MO |
| 3715.02-3964.98 MHz | 0.991 | 2.5ppm | EP, MO |
| 3720-3975 MHz | 0.877 | 2.5ppm | EP, MO |
| 3750-3929.97 MHz | 0.946 | 2.5ppm | EP, MO |
| 5190-5230 MHz | 0.598 | CC, MO | |
| 5210 MHz | 0.476 | CC, MO | |
| 5250 MHz | 0.198 | CC, MO | |
| 5260-5320 MHz | 0.181 | CC, MO | |
| 5270-5310 MHz | 0.234 | CC, MO | |
| 5290 MHz | 0.148 | CC, MO | |
| 5500-5700 MHz | 0.175 | CC, MO | |
| 5510-5670 MHz | 0.247 | CC, MO | |
| 5530-5610 MHz | 0.216 | CC, MO | |
| 5570 MHz | 0.224 | CC, MO | |
| 5745-5825 MHz | 0.61 | CC, MO | |
| 5755-5795 MHz | 0.568 | CC, MO | |
| 5775 MHz | 0.561 | CC, MO | |
| 5955-7095 MHz | 0.044 | CC, EP, MO | |
| 5965-7085 MHz | 0.089 | CC, EP, MO | |
| 5985-7025 MHz | 0.168 | CC, EP, MO | |
| 6025-6985 MHz | 0.353 | CC, EP, MO | |
| 6105-6905 MHz | 0.446 | CC, EP, MO |
Grants
TCB Grant - Application V5WjKRiDKwJwdSJDnrOXrg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 04/01/2025 Application Dated: 04/01/2025 |
| ST Engineering Advanced Networks & Sensors Pte. Ltd. |
| 100 Jurong East Street 21 |
| Singapore, 609602 Singapore |
| Attention: Hua Chong Lim , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BLGT-AGILSC250WIFI |
| Name of Grantee: | ST Engineering Advanced Networks & Sensors Pte. Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | 5GSC-250-WIFI |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.326 | ||
| CC MO | 15C | 2422.0 - 2452.0 | 0.308 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 41 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. This device has 20 MHz, 40 MHz bandwidth modes. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
TCB Grant - Application pCvrWul53qeuwz6RuC9vZg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 04/01/2025 Application Dated: 04/01/2025 |
| ST Engineering Advanced Networks & Sensors Pte. Ltd. |
| 100 Jurong East Street 21 |
| Singapore, 609602 Singapore |
| Attention: Hua Chong Lim , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BLGT-AGILSC250WIFI |
| Name of Grantee: | ST Engineering Advanced Networks & Sensors Pte. Ltd. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | 5GSC-250-WIFI |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15E | 5180.0 - 5240.0 | 0.608 | ||
| CC MO | 15E | 5190.0 - 5230.0 | 0.598 | ||
| CC MO | 15E | 5210.0 - 5210.0 | 0.476 | ||
| CC MO | 15E | 5260.0 - 5320.0 | 0.181 | ||
| CC MO | 15E | 5270.0 - 5310.0 | 0.234 | ||
| CC MO | 15E | 5290.0 - 5290.0 | 0.148 | ||
| CC MO | 15E | 5250.0 - 5250.0 | 0.198 | ||
| CC MO | 15E | 5500.0 - 5700.0 | 0.175 | ||
| CC MO | 15E | 5510.0 - 5670.0 | 0.247 | ||
| CC MO | 15E | 5530.0 - 5610.0 | 0.216 | ||
| CC MO | 15E | 5570.0 - 5570.0 | 0.224 | ||
| CC MO | 15E | 5745.0 - 5825.0 | 0.61 | ||
| CC MO | 15E | 5755.0 - 5795.0 | 0.568 | ||
| CC MO | 15E | 5775.0 - 5775.0 | 0.561 |
| Output power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 41 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. This device has 20 MHz, 40 MHz, 80 MHz and 160 MHz bandwidth modes |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
TCB Grant - Application n9znlRclX4mvx8+ciQc3Dg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 04/01/2025 Application Dated: 04/01/2025 |
| ST Engineering Advanced Networks & Sensors Pte. Ltd. |
| 100 Jurong East Street 21 |
| Singapore, 609602 Singapore |
| Attention: Hua Chong Lim , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BLGT-AGILSC250WIFI |
| Name of Grantee: | ST Engineering Advanced Networks & Sensors Pte. Ltd. |
| Equipment Class: | 15E 6 GHz Low Power Indoor Access Point |
| Notes: | 5GSC-250-WIFI |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC EP MO | 15E | 5955.0 - 7095.0 | 0.044 | ||
| CC EP MO | 15E | 5965.0 - 7085.0 | 0.089 | ||
| CC EP MO | 15E | 5985.0 - 7025.0 | 0.168 | ||
| CC EP MO | 15E | 6025.0 - 6985.0 | 0.353 | ||
| CC EP MO | 15E | 6105.0 - 6905.0 | 0.446 |
| Output power listed is EIRP. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 41 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. This device has 20 MHz, 40 MHz, 80 MHz, 160 MHz and 320 MHz bandwidth modes. 6GHz operation is intended for indoor use only. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
TCB Grant - Application bd8ZsJVHyGcQIgZuZ400nQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 04/02/2025 Application Dated: 04/02/2025 |
| ST Engineering Advanced Networks & Sensors Pte. Ltd. |
| 100 Jurong East Street 21 |
| Singapore, 609602 Singapore |
| Attention: Hua Chong Lim , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BLGT-AGILSC250WIFI |
| Name of Grantee: | ST Engineering Advanced Networks & Sensors Pte. Ltd. |
| Equipment Class: | Citizens Band Category A and B Devices |
| Notes: | 5GSC-250-WIFI |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 96 | 3565.02 - 3684.99 | 0.991 | 2.5 PM | 28M0G7D |
| EP MO | 96 | 3600.0 - 3649.98 | 0.984 | 2.5 PM | 98M8G7D |
| EP MO | 96 | 3570.0 - 3694.98 | 0.869 | 2.5 PM | 97M1G7D |
| Output power listed is EIRP per antenna port. This device must be installed to provide a separation distance of at least 41 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. This device supports single carrier 10, 20, 30, 40, 60 and 100 MHz bandwidth, and CA_2CC: 10+10, 20+20, 30+10, 30+20, 40+20, 40+40, 60+20, CA_3CC: 10+10+10, 20+20+20, 40+20+10, 40+30+20, 40+20+20, CA_4CC: 40+30+20+10, 20+20+20+20 MHz bandwidth for 5G NR n48, n77, n78. Installers and end-users must be provided with installation instructions and transmitter operating conditions and instructions for satisfying RF exposure compliance. |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
TCB Grant - Application BcMQ/WT+QVhVWhwktbYJXQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
SGS North America, Inc. 620 Old Peachtree Road NW Suite 100 Suwanee, GA 30024 |
Date of Grant: 04/02/2025 Application Dated: 04/02/2025 |
| ST Engineering Advanced Networks & Sensors Pte. Ltd. |
| 100 Jurong East Street 21 |
| Singapore, 609602 Singapore |
| Attention: Hua Chong Lim , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BLGT-AGILSC250WIFI |
| Name of Grantee: | ST Engineering Advanced Networks & Sensors Pte. Ltd. |
| Equipment Class: | Licensed Non-Broadcast Station Transmitter |
| Notes: | 5GSC-250-WIFI |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| EP MO | 27 | 3499.98 - 3499.98 | 0.838 | 2.5 PM | 98M8G7D |
| EP MO | 27 | 3459.99 - 3540.0 | 0.998 | 2.5 PM | 18M4G7D |
| EP MO | 27 | 3470.01 - 3544.98 | 0.891 | 2.5 PM | 97M0G7D |
| EP MO | 27 | 3715.02 - 3964.98 | 0.991 | 2.5 PM | 28M0G7D |
| EP MO | 27 | 3750.0 - 3929.97 | 0.946 | 2.5 PM | 98M8G7D |
| EP MO | 27 | 3720.0 - 3975.0 | 0.877 | 2.5 PM | 97M0G7D |
| Output power listed is EIRP per antenna port. This device must be installed to provide a separation distance of at least 41 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures, or as evaluated in this filing. This device supports single carrier 10, 20, 30, 40, 60 and 100 MHz bandwidth, and CA_2CC: 10+10, 20+20, 30+10, 30+20, 40+20, 40+40, 60+20, CA_3CC: 10+10+10, 20+20+20, 40+20+10, 40+30+20, 40+20+20, CA_4CC: 40+30+20+10, 20+20+20+20 MHz bandwidth for 5G NR n77, n78. Installers and end-users must be provided with installation instructions and transmitter operating conditions and instructions for satisfying RF exposure compliance. |
| EP: | Output power is Effective Isotropic Radiated Power (EIRP) |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |