FCC ID 2BMNE-WT-002

Neurostimulator Powering Device

by Neuspera Medical Inc.

Grantee Code: 2BMNE   Product Code: WT002
Latest application date: 2025-05-20

FCC ID Device Details

FCC ID2BMNE-WT-002
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BMNE
Product CodeWT002
Applicant BusinessNeuspera Medical Inc. 🇺🇸
Related Domains neuspera.com
Equipment ClassNeurostimulator Powering Device
Test FirmBay Area Compliance Laboratories Corp.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.2-912 MHzOriginal Equipment2025-05-20

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2025-11-16PDF 1.6 MB
Internal PhotosInternal Photos2025-11-16PDF 645.9 KB
External PhotosExternal Photos2025-11-16PDF 356.2 KB
Label & Label LocationID Label/Location Info2025-05-20PDF 256.9 KB
SAR EUT Test Position PhotosTest Setup Photos2025-11-16PDF 1.3 MB
Test Setup PhotosTest Setup Photos2025-11-16PDF 679 KB
Antenna SpecificationTest Report2025-05-20PDF 518.4 KB
Test ReportTest Report2025-05-20PDF 1.6 MB
2.911 (d)(5)(i) Attestation StatementAttestation Statements2025-05-20PDF 302.7 KB
2.911 (d)(5)(ii) Attestation StatementAttestation Statements2025-05-20PDF 321.4 KB
US Agent Attestation LetterAttestation Statements2025-05-20PDF 199.5 KB
FCC Agent Authorization LetterCover Letter(s)2025-05-20PDF 32.9 KB
FCC Long and Short term Confidentiality RequestCover Letter(s)2025-05-20PDF 155.8 KB
RF ExposureRF Exposure Info2025-05-20PDF 294.7 KB
SAR ReportRF Exposure Info2025-05-20PDF 3.8 MB
Block Diagram Metadata onlyBlock DiagramPDF 526.2 KB
Schematics Part 1 Metadata onlySchematicsPDF 984.4 KB
Schematics Part 2 Metadata onlySchematicsPDF 4.6 MB
Operation Description Metadata onlyOperational DescriptionPDF 450.3 KB

Application Information

Application IDr4BN3DPg6fQa6D9VGAMKkg==
Final Action Date2025-05-20
Application PurposeOriginal Equipment
Applicant FRN0035267715
ModelWT-002
Frequency Range902.2-912 MHz
Equipment ClassDSS - Part 15 Spread Spectrum Transmitter
Device DescriptionNeurostimulator Powering Device
Responsible PartyAlexander Yeh, alexyeh@neuspera.com , 888-846-8332
Test FirmLisa Tang, Bay Area Compliance Laboratories Corp., lisat@baclcorp.com , 408-732-9162
TCB Emailbacl.regulatory@baclcorp.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityYes
Short-Term Confidentiality Date11/16/2025
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput power listed is conducted total power. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. To satisfy FCC RF exposure compliance requirements, body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 6.5 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR value for Body-worn exposure condition is 1.43 W/kg.

Applications

Application IDDatePurpose
r4BN3DPg6fQa6D9VGAMKkg==2025-05-20Original Equipment

Equipment Authorization

FrequencyOutputGrant Notes
902.2-912 MHz0.9790000MO

Grants

TCB Grant - Application r4BN3DPg6fQa6D9VGAMKkg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Bay Area Compliance Laboratories Corp.
1274 Anvilwood Avenue
Sunnyvale, CA 94089
Date of Grant: 05/20/2025

Application Dated: 05/20/2025
Neuspera Medical Inc.
51 Daggett Drive
San Jose, CA 95134
 
Attention: Alexander Yeh ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BMNE-WT-002
Name of Grantee:  Neuspera Medical Inc.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Neurostimulator Powering Device
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15C 902.2  -  912.0 0.979  

Output power listed is conducted total power. The antenna(s) used for this transmitter must not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. To satisfy FCC RF exposure compliance requirements, body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 6.5 mm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR value for Body-worn exposure condition is 1.43 W/kg.

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.