FCC ID 2BNBX-CBGNHB2X2M2B

Base Station

by Cambridge Broadband Networks Group Ltd

Grantee Code: 2BNBX   Product Code: CBGNHB2X2M2B
Latest application date: 2025-02-12

FCC ID Device Details

FCC ID2BNBX-CBGNHB2X2M2B
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BNBX
Product CodeCBGNHB2X2M2B
Applicant BusinessCambridge Broadband Networks Group Ltd 🇬🇧
Related Domains cbng.co.uk
Equipment ClassBase Station
Test FirmUL LLC

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
37000-40000 MHzOriginal Equipment2025-02-12

Exhibits

DocumentTypeAvailableFile
CBNG 39GHz AP OD v1_1 Regulatory InfoUsers Manual2025-03-14PDF 188.3 KB
CBNG 39GHz AP Operational Manual v1_2Users Manual2025-03-14PDF 1.3 MB
Internal photos_CompressedInternal Photos2025-03-14PDF 675.8 KB
External photos_Part1External Photos2025-03-14PDF 4.6 MB
External photos_Part2External Photos2025-03-14PDF 3.4 MB
CBNG AP Label with UL supplied FCC Logo 05_02_2025 - IoTASID Label/Location Info2025-02-12PDF 124.7 KB
R15511125-EP1 v1 FCC Part 30 Setup PhotosTest Setup Photos2025-03-14PDF 1.2 MB
R15511125-E1 v2 FCC Part 30 ReportTest Report2025-02-12PDF 3.7 MB
FCC Agent for service Attestation from Agent finalAttestation Statements2025-02-12PDF 249.2 KB
FCC_2.911d5_Attestation_CBNG_signedAttestation Statements2025-02-12PDF 220 KB
FCC_Agent_for_service_Attestation_from_ApplicantAttestation Statements2025-02-12PDF 221.4 KB
FCC_Agent_Auth_Letter_[UL_LLC]_CBNG_signedCover Letter(s)2025-02-12PDF 266.6 KB
FCC_Request_for_Confidentiality_Letter_[Long_and_Short_Term]_signed_rev_2Cover Letter(s)2025-02-12PDF 283.1 KB
R15511125-E3 v1 FCC MPE ReportRF Exposure Info2025-02-12PDF 166.3 KB
No.2_Block_Diagram_20250211 Metadata onlyBlock DiagramPDF 236.7 KB
No.3-2_Circuit_Diagram_RF v01_20240720 Metadata onlySchematicsPDF 1.6 MB
No.3-4_Circuit_Diagram_PWR v02_20241203 Metadata onlySchematicsPDF 75.2 KB
No.3-5_Circuit_Diagram_RF v02_20241203 Metadata onlySchematicsPDF 1.6 MB
No.3-6_Circuit_Diagram_MB v02_20241203 Metadata onlySchematicsPDF 3.2 MB
No.3-7_Circuit_Diagram_MB v03_20241203 Metadata onlySchematicsPDF 3.2 MB
CB-GN-HB-2X2M-2B_Antenna Spec_20250124 Metadata onlyOperational DescriptionPDF 552.5 KB
CBNG 39GHz AP Operational Description v1_2 Metadata onlyOperational DescriptionPDF 1.3 MB
CBNG 39GHz AP Tune Up Exhibit Metadata onlyParts List/Tune Up InfoPDF 48.6 KB

Application Information

Application IDOD7ogtex8QIGYNzaYn4Lhg==
Final Action Date2025-02-12
Application PurposeOriginal Equipment
Applicant FRN0036487932
ModelCBGNHB2X2M2B
Frequency Range37000-40000 MHz
Equipment Class5GB - Part 30 Fixed Transmitter
Device DescriptionBase Station
Responsible PartyJustin W Clark, CTO, justin.clark@cbng.co.uk , +44 7958 617 714
Technical ContactJustin Clark, Cambridge Broadband Networks Group Ltd., justin.clark@cbng.co.uk , 07958617714
Test FirmSteven Thompson, UL LLC, steven.d.thompson@ul.com , 919 549 1430
TCB EmailLST.FRE.CertNotice@ul.com
TCB ScopeB4: Microwave, Millimeter Wave Band and Citizens Broadband Radio Services equipment in 47 CFR Parts 25, 30, 74, 90, 95, 96, 97, 101 (all above 3 GHz)
Short-Term ConfidentialityYes
Short-Term Confidentiality Date03/14/2025
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is maximum EIRP. This device supports single carrier bandwidths of 100, 200, and 400 MHz. This device supports multi-carrier operations for 4- and 8-carriers with a maximum aggregated bandwidth of 800 MHz. The powers listed are the maximum powers for each single carrier bandwidth and for the maximum aggregated-bandwidth. The transmitters must be installed to maintain a minimum of 0.349 meters separation from bystanders to comply with the General Population / Uncontrolled MPE limit and requirements. Installers/operators must be provided with installation and transmitter operating conditions for satisfying RF exposure compliance.

Applications

Application IDDatePurpose
OD7ogtex8QIGYNzaYn4Lhg==2025-02-12Original Equipment

Equipment Authorization

FrequencyOutputToleranceRulesGrant Notes
37000-40000 MHz1412.544.4ppm1412.54EP, MO
37000-40000 MHz1288.254.4ppm1288.25EP, MO
37000-40000 MHz1527.574.4ppm1527.57EP, MO

Grants

TCB Grant - Application OD7ogtex8QIGYNzaYn4Lhg==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  UL Verification Services Inc.
47173 Benicia Street
Fremont, CA 94538
Date of Grant: 02/12/2025

Application Dated: 02/12/2025
Cambridge Broadband Networks Group Ltd
Suites 1a & 1b, Enterprise House
Vision Park, Histon
Cambridge, CB24 9ZR
United Kingdom
 
Attention: Justin Clark , CTO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BNBX-CBGNHB2X2M2B
Name of Grantee:  Cambridge Broadband Networks Group Ltd
Equipment Class: Part 30 Fixed Transmitter
Notes: Base Station
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EP MO 30 37000.0  -  40000.0 1412.54 4.4  PM 95M6D7D
EP MO 30 37000.0  -  40000.0 1288.25 4.4  PM 194MD7D
EP MO 30 37000.0  -  40000.0 1288.25 4.4  PM 381MD7D
EP MO 30 37000.0  -  40000.0 1527.57 4.4  PM 791MD7D

Output Power listed is maximum EIRP. This device supports single carrier bandwidths of 100, 200, and 400 MHz. This device supports multi-carrier operations for 4- and 8-carriers with a maximum aggregated bandwidth of 800 MHz. The powers listed are the maximum powers for each single carrier bandwidth and for the maximum aggregated-bandwidth.

The transmitters must be installed to maintain a minimum of 0.349 meters separation from bystanders to comply with the General Population / Uncontrolled MPE limit and requirements. Installers/operators must be provided with installation and transmitter operating conditions for satisfying RF exposure compliance.


EP: Output power is Effective Isotropic Radiated Power (EIRP)
MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.