FCC ID 2BNUMIRIS

Surgical equipment for ophthalmic surgeries

by Vitreq B.V.

Grantee Code: 2BNUM   Product Code: IRIS
Latest application date: 2026-04-21

FCC ID Device Details

FCC ID2BNUMIRIS
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BNUM
Product CodeIRIS
Applicant BusinessVitreq B.V. 🇳🇱
Related Domains bvimedical.com
Equipment ClassSurgical equipment for ophthalmic surgeries
Test FirmDEKRA Certification B.V.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
13.56 MHzOriginal Equipment2026-04-21
2402-2480 MHzOriginal Equipment2026-04-21

Exhibits

DocumentTypeAvailableFile
9-FCB012_05 FCC Confidentiality Request_v2.pdfExternal Photos2026-04-21PDF 131.9 KB
13-Label design and location_v2.pdfID Label/Location Info2026-04-21PDF 222.9 KB
47-2285019.0509A-EMC_Photograph.pdfTest Setup Photos2026-04-21PDF 1.2 MB
48-test setup photos.pdfTest Setup Photos2026-04-21PDF 3.4 MB
49-test setup photos 2.pdfTest Setup Photos2026-04-21PDF 3.9 MB
23-81122RAN.003s - 1.SAR Test report.pdfRF Exposure Info2026-04-21PDF 1.4 MB
41-Antenna data.pdfTest Report2026-04-21PDF 88.1 KB
42-2285019.0506A-RSM Collocation.pdfTest Report2026-04-21PDF 2.7 MB
43-2285019.0503B-RSM.pdfTest Report2026-04-21PDF 1.9 MB
44-2285019.0509A-EMC.pdfTest Report2026-04-21PDF 1.7 MB
45-report 2013.pdfTest Report2026-04-21PDF 4.2 MB
1-FCB045_01 Certifications concerning covered equipment.pdfAttestation Statements2026-04-21PDF 202.8 KB
2-FCB046_02 Certification designating a U.S. agent.pdfAttestation Statements2026-04-21PDF 261.8 KB
10-Integration declaration 06MAR2026_signed.pdfCover Letter(s)2026-04-21PDF 460.6 KB
20-Declaration_Letter_of_Authorization_Ezurio_Vitreq.pdfCover Letter(s)2026-04-21PDF 228.2 KB
6-FCB011_02 FCC Agent letter_VTQ_signed.pdfCover Letter(s)2026-04-21PDF 56.9 KB
7-Antenna gain_cover letter_signed PA.pdfCover Letter(s)2026-04-21PDF 82.7 KB
8-Declaration of Similarity_pa.pdfCover Letter(s)2026-04-21PDF 666.6 KB
9-FCB012_05 FCC Confidentiality Request_v2.pdfCover Letter(s)2026-04-21PDF 131.9 KB
21-81122RAN.003 - 2.SAR Calibration Data.pdfRF Exposure Info2026-04-21PDF 2.7 MB
22-81122RAN.004s - RF Exp - FCC.pdfRF Exposure Info2026-04-21PDF 975.6 KB
50-IFUS-94000029 v07 Virtuoso Operators Manual_Parte1.pdf Metadata onlyUsers Manual2026-10-18PDF 5.6 MB
51-IFUS-94000029 v07 Virtuoso Operators Manual_Parte2.pdf Metadata onlyUsers Manual2026-10-18PDF 5.6 MB
52-IFUS-94000029 v07 Virtuoso Operators Manual_Parte3.pdf Metadata onlyUsers Manual2026-10-18PDF 5.3 MB
53-IFUS-94000029 v07 Virtuoso Operators Manual_Parte4.pdf Metadata onlyUsers Manual2026-10-18PDF 4.6 MB
14-Internal photos_v3.pdf Metadata onlyInternal Photos2026-10-18PDF 973.5 KB
15-internal photos.pdf Metadata onlyInternal Photos2026-10-18PDF 1.3 MB
11-External photos_v3.pdf Metadata onlyExternal Photos2026-10-18PDF 406.5 KB
12-External photos.pdf Metadata onlyExternal Photos2026-10-18PDF 1.8 MB
46-81122RAN.003 - 3.SAR Photographs.pdfTest Setup Photos2026-10-18PDF 803 KB
3-Block diagram.pdf Metadata onlyBlock DiagramPDF 2.5 MB
4-RFID_block_diagram.pdf Metadata onlyBlock DiagramPDF 14.4 KB
5-Block diagram_BT740.pdf Metadata onlyBlock DiagramPDF 154.3 KB
24-300759 LZ1 Schema 20220620.pdf Metadata onlySchematicsPDF 17.7 KB
25-D119093_SCH_HSC_MRRN_2.5BDSB3_v2.0.pdf Metadata onlySchematicsPDF 117.2 KB
25-D119093_SCH_HSC_MRRN_2.5BDSB3_v2.0.pdfb Metadata onlySchematicsPDF 117.2 KB
26-D179793_SCH_display_musbra_v2.0.pdf Metadata onlySchematicsPDF 68.6 KB
27-D242204_SCH_Cartridge_LEDs_V1.0.pdf Metadata onlySchematicsPDF 139.8 KB
28-D242212_SCH_PSD_Flexrigid_V1.0.pdf Metadata onlySchematicsPDF 263.4 KB
28-D242212_SCH_PSD_Flexrigid_V1.0.pdfb Metadata onlySchematicsPDF 263.4 KB
29-D246739_SCH_HSCMLNT010BASB3_V3.0.pdf Metadata onlySchematicsPDF 116.7 KB
30-D400314_SCH_Mainboard_Iris_Gamma_v2.0_r.pdf Metadata onlySchematicsPDF 4.2 MB
31-D409832_SCH_Pump_Gamma_V1.0.pdf Metadata onlySchematicsPDF 2.7 MB
32-D485582_SCH_Manifold_PS_Gamma_V3.0.pdf Metadata onlySchematicsPDF 318.8 KB
33-D491028_SCH_Illumination_Controller_Gamma_v1.0.pdf Metadata onlySchematicsPDF 2.5 MB
34-D511856_SCH_AIR_PCA_v2.0.pdf Metadata onlySchematicsPDF 630.3 KB
35-D511858_SCH_VFIE_VITREC_PCA_v1.0.pdf Metadata onlySchematicsPDF 611.3 KB
36-D530447_SCH_IR_TEMP_SENS_PCA_v1.0.pdf Metadata onlySchematicsPDF 93.2 KB
37-D566533_SCH_PanelPC_Isolator_Gamma_PCA_v2.0.pdf Metadata onlySchematicsPDF 985.9 KB
38-D572019_SCH_Illumination_Frontpanel_Gamma_v1.0.pdf Metadata onlySchematicsPDF 679 KB
39-RFID schematics_D242197_SCH_Laser_Frontpanel_V3.0.pdf Metadata onlySchematicsPDF 1.1 MB
40-BT740 SA SC Schema.pdf Metadata onlySchematicsPDF 209.2 KB
16-PRD0412-5-626_4.0_HDD-EL_Main_Parte1-Operational_Desc.pdf Metadata onlyOperational DescriptionPDF 4.8 MB
17-trf7960_RFID chipset.pdf Metadata onlyOperational DescriptionPDF 1.7 MB
18-PRD0412-5-626_4.0_HDD-EL_Main_Parte2-Operational_Desc.pdf Metadata onlyOperational DescriptionPDF 2.7 MB
19-Datasheet (BT740 series).pdf Metadata onlyOperational DescriptionPDF 3.9 MB

Application Information

Application IDmNDwwPsi7rwlcSbaDGLQlw==
Final Action Date2026-04-21
Application PurposeOriginal Equipment
Applicant FRN0036891265
ModelIRIS
Frequency Range13.56 MHz
Equipment ClassDXX - Part 15 Low Power Communication Device Transmitter
Device DescriptionSurgical equipment for ophthalmic surgeries
Responsible PartyChristian Neele, cneele@bvimedical.com , 310611128427
Non-Technical ContactChris Brady, BVI Medical, cbrad@bvimedical.com , +6178880007
Test FirmGiancarlo Christiaans, DEKRA Certification B.V., giancarlo.christiaans@dekra.com , +31 88 968 3000
TCB Emailadmin.rcb.es@dekra.com
TCB ScopeA1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
Short-Term ConfidentialityYes
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
mNDwwPsi7rwlcSbaDGLQlw==2026-04-21Original Equipment
PvggZs/v11foW5gIWi/E1w==2026-04-21Original Equipment
Gx+7//EfYYMdf0JQMdJXSQ==2026-04-21Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
15BCC
13.56 MHz15CCC
2402-2480 MHz0.1002315CCC

Grants

TCB Grant - Application PvggZs/v11foW5gIWi/E1w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  DEKRA Testing and Certification, S.A.U.
Parque Tecnologico de Andalucia, Calle Severo Ochoa 2 y 6
Campanillas - Malaga, 29590
Spain
Date of Grant: 04/21/2026

Application Dated: 04/21/2026
Vitreq B.V.
Seggelant-Noord 2
Vierpolders, 3237 MG
Netherlands
 
Attention: Christian Neele ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BNUMIRIS
Name of Grantee:  Vitreq B.V.
Equipment Class: Part 15 Class B Digital Device
Notes: Surgical equipment for ophthalmic surgeries
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15B  - 


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application mNDwwPsi7rwlcSbaDGLQlw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  DEKRA Testing and Certification, S.A.U.
Parque Tecnologico de Andalucia, Calle Severo Ochoa 2 y 6
Campanillas - Malaga, 29590
Spain
Date of Grant: 04/21/2026

Application Dated: 04/20/2026
Vitreq B.V.
Seggelant-Noord 2
Vierpolders, 3237 MG
Netherlands
 
Attention: Christian Neele ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BNUMIRIS
Name of Grantee:  Vitreq B.V.
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: Surgical equipment for ophthalmic surgeries
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 13.56  -  13.56  

This device is approved for mobile and fixed use with respect to RF exposure compliance. The antenna of this transmitter must provide a separation distance of at least 20 cm from all persons.

Multi-transmitter configurations, supporting simultaneous transmission, have been evaluated as described in this filling. Other multi-transmitter configurations have not been evaluated and shall be evaluated according to KDB Publication 447498 and §2.947(f), §15.31(h) and §15.31(k) composite system and §2.1 terms and concepts.


CC: This device is certified pursuant to two different Part 15 rules sections.

TCB Grant - Application Gx+7//EfYYMdf0JQMdJXSQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  DEKRA Testing and Certification, S.A.U.
Parque Tecnologico de Andalucia, Calle Severo Ochoa 2 y 6
Campanillas - Malaga, 29590
Spain
Date of Grant: 04/21/2026

Application Dated: 04/21/2026
Vitreq B.V.
Seggelant-Noord 2
Vierpolders, 3237 MG
Netherlands
 
Attention: Christian Neele ,

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BNUMIRIS
Name of Grantee:  Vitreq B.V.
Equipment Class: Part 15 Spread Spectrum Transmitter
Notes: Surgical equipment for ophthalmic surgeries
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
CC 15C 2402.0  -  2480.0 0.10023  

Output power listed is conducted.

The Main Unit is approved for mobile and fixed use with respect to RF exposure compliance. The antenna of this transmitter must provide a separation distance of at least 20 cm from all persons.

The Foot Pedal meets the SAR Test Exclusion threshold specified in KDB 447498 and since then, it is authorized for portable operation.

For the Remote Control, the highest reported SAR for body and extremity exposure conditions are 0.301 W/kg and 0.136 W/kg, respectively.

Multi-transmitter configurations, supporting simultaneous transmission, have been evaluated as described in this filling. Other multi-transmitter configurations have not been evaluated and shall be evaluated according to KDB Publication 447498 and §2.947(f), §15.31(h) and §15.31(k) composite system and §2.1 terms and concepts.


CC: This device is certified pursuant to two different Part 15 rules sections.