FCC ID 2BO2A-HYB001P

TRACKER

by SHENZHEN HUIYE IOT TECHNOLOGY CO.,LTD.

Grantee Code: 2BO2A   Product Code: HYB001P
Latest application date: 2025-12-16

FCC ID Device Details

FCC ID2BO2A-HYB001P
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BO2A
Product CodeHYB001P
Applicant BusinessSHENZHEN HUIYE IOT TECHNOLOGY CO.,LTD. 🇨🇳
Related Domains huiye.com
Equipment ClassTRACKER
Test FirmGuangdong DN Testing Co., Ltd.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2500-2570 MHzOriginal Equipment2025-12-16
2402-2480 MHzOriginal Equipment2025-12-15

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2025-12-16PDF 465.1 KB
Internal PhotosInternal Photos2025-12-16PDF 858.3 KB
External PhotosExternal Photos2025-12-16PDF 744.4 KB
Label and locationID Label/Location Info2025-12-16PDF 165.5 KB
Test setup photosTest Setup Photos2025-12-16PDF 488 KB
Antenna SpecificationTest Report2025-12-16PDF 635.9 KB
FCC LTE Test ReportTest Report2025-12-16PDF 1.4 MB
FCC BLE Test Report_Part1Test Report2025-12-15PDF 5.8 MB
FCC BLE Test Report_Part2Test Report2025-12-15PDF 2.4 MB
USA-CoveredEquipmentLetter-Combined_V1.1Attestation Statements2025-12-16PDF 119.2 KB
USA-LocalRepLetter_V1.1 -2BO2A-HYB001PAttestation Statements2025-12-16PDF 342.8 KB
FCC Statement for re-use data from modulesCover Letter(s)2025-12-16PDF 91.6 KB
NEW ID Statement-US_re-use data of modulesCover Letter(s)2025-12-16PDF 137.7 KB
USA-ConfidentialityRequestLetter_V0.1Cover Letter(s)2025-12-16PDF 99.3 KB
FCC MPE(Mobile) ReportRF Exposure Info2025-12-16PDF 810.8 KB
Block diagram Metadata onlyBlock DiagramPDF 85.1 KB
Schematic Metadata onlySchematicsPDF 435.8 KB
Operation Description Metadata onlyOperational DescriptionPDF 1.3 MB
USA-DueDigilenceLetter_V0.1 Metadata onlyOperational DescriptionPDF 76.1 KB
BOM Metadata onlyParts List/Tune Up InfoPDF 193.3 KB

Application Information

Application IDzT0dAxVU5++YdLo/QWpvxw==
Final Action Date2025-12-16
Application PurposeOriginal Equipment
Applicant FRN0036969806
ModelHYB001P
Frequency Range2500-2570 MHz
Equipment ClassPCB - PCS Licensed Transmitter
Device DescriptionTRACKER
Responsible Partyliling fu, fuliling@huiye.com , 18682045898
Non-Technical ContactCindy Wu, HOORAY INDUSTRY LLC, cindynewhope@gmail.com , (626) 910-5808
Test FirmJoise Yang, Guangdong DN Testing Co., Ltd., Joise.yang@dn-testing.com , +86-0769-8808 7383
TCB Emailo.kneip@kl-certification.de
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
zT0dAxVU5++YdLo/QWpvxw==2025-12-16Original Equipment
vA/Jasl6KNXbWrtmUHe86w==2025-12-15Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
1850-1910 MHz0.26182.5 PM2M68G7D24E
1850-1910 MHz0.23992.5 PM17M7G7D24E
1710-1755 MHz0.26672.5 PM2M68G7D27
1710-1755 MHz0.24662.5 PM17M9G7D27
824-849 MHz0.10942.5 PM8M88G7D22H
2500-2570 MHz0.23332.5 PM17M9G7D27
1710-1780 MHz0.26672.5 PM2M68G7D27
1710-1780 MHz0.24662.5 PM17M9G7D27
2402-2480 MHz0.002815C

Grants

TCB Grant - Application zT0dAxVU5++YdLo/QWpvxw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  KL-Certification GmbH
Heinrich-Hertz-Allee 7
St. Ingbert, 66386
Germany
Date of Grant: 12/16/2025

Application Dated: 12/15/2025
SHENZHEN HUIYE IOT TECHNOLOGY CO.,LTD.
No.39,Zhulongtian Road,Shuitian Community,
Shiyan Street,Baoan,
Shenzhen, Guangdong,,
China
 
Attention: liling fu , CTO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BO2A-HYB001P
Name of Grantee:  SHENZHEN HUIYE IOT TECHNOLOGY CO.,LTD.
Equipment Class: PCS Licensed Transmitter
Notes: TRACKER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.0  -  1910.0 0.2618 2.5  PM 2M68G7D
24E 1850.0  -  1910.0 0.2399 2.5  PM 17M7G7D
27 1710.0  -  1755.0 0.2667 2.5  PM 2M68G7D
27 1710.0  -  1755.0 0.2466 2.5  PM 17M9G7D
22H 824.0  -  849.0 0.1094 2.5  PM 8M88G7D
27 2500.0  -  2570.0 0.2333 2.5  PM 17M9G7D
27 1710.0  -  1780.0 0.2667 2.5  PM 2M68G7D
27 1710.0  -  1780.0 0.2466 2.5  PM 17M9G7D

Output power listed is ERP for operation below 1GHz and EIRP for operation above 1GHz. This device supports LTE bandwidths of 1.4, 3, 5, 10, 15, 20 MHz at LTE Band 2/4/66 and of 1.4, 3, 5, 10 MHz at LTE Band 5 and of 5, 10, 15, 20 MHz at LTE Band 7. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

TCB Grant - Application vA/Jasl6KNXbWrtmUHe86w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  KL-Certification GmbH
Heinrich-Hertz-Allee 7
St. Ingbert, 66386
Germany
Date of Grant: 12/15/2025

Application Dated: 12/15/2025
SHENZHEN HUIYE IOT TECHNOLOGY CO.,LTD.
No.39,Zhulongtian Road,Shuitian Community,
Shiyan Street,Baoan,
Shenzhen, Guangdong,,
China
 
Attention: liling fu , CTO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BO2A-HYB001P
Name of Grantee:  SHENZHEN HUIYE IOT TECHNOLOGY CO.,LTD.
Equipment Class: Digital Transmission System
Notes: TRACKER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2402.0  -  2480.0 0.0028  

Output Power listed is peak conducted. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.