FCC ID 2BQHGIV-4G-1
Northlight 4G
by INTELLI GROUP
Grantee Code: 2BQHG Product Code: IV4G1
Latest application date: 2025-08-27
FCC ID Device Details
| FCC ID | 2BQHGIV-4G-1 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2BQHG |
| Product Code | IV4G1 |
| Applicant Business | INTELLI GROUP 🇨🇦 |
| Related Domains | |
| Equipment Class | Northlight 4G |
| Test Firm | Shenzhen NTEK Testing Technology Co., Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Original Equipment | 2025-08-27 |
| 673-688 MHz | Original Equipment | 2025-08-27 |
| 2412-2462 MHz | Original Equipment | 2025-08-26 |
| 2402-2480 MHz | Original Equipment | 2025-08-26 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2026-02-23 | PDF 3 MB |
| User manual | Users Manual | 2026-02-23 | PDF 3 MB |
| Internal Photos | Internal Photos | 2026-02-23 | PDF 1.3 MB |
| Internal photo | Internal Photos | 2026-02-23 | PDF 1.3 MB |
| Internal photos | Internal Photos | 2026-02-23 | PDF 1.3 MB |
| External Photos | External Photos | 2026-02-23 | PDF 964.2 KB |
| External photos | External Photos | 2026-02-23 | PDF 964.2 KB |
| external photo | External Photos | 2026-02-23 | PDF 964.2 KB |
| Label | ID Label/Location Info | 2025-08-27 | PDF 396.9 KB |
| label | ID Label/Location Info | 2025-08-27 | PDF 396.9 KB |
| Test Setup photo---DSS | Test Setup Photos | 2026-02-23 | PDF 560.8 KB |
| Test Setup photo---DTS | Test Setup Photos | 2026-02-23 | PDF 560.8 KB |
| Test Setup photo---NII | Test Setup Photos | 2026-02-23 | PDF 731.3 KB |
| Test Setup photo---PCE | Test Setup Photos | 2026-02-23 | PDF 509.1 KB |
| Test Setup photo---SAR | Test Setup Photos | 2026-02-23 | PDF 317.8 KB |
| 2G&3G | Test Report | 2025-08-27 | PDF 901.6 KB |
| 4G | Test Report | 2025-08-27 | PDF 3 MB |
| 5GWIFI | Test Report | 2025-08-27 | PDF 1.6 MB |
| ANT | Test Report | 2025-08-27 | PDF 805 KB |
| ANT | Test Report | 2025-08-27 | PDF 1,012.2 KB |
| Attachment for 2G | Test Report | 2025-08-27 | PDF 2.5 MB |
| Attachment for 3G | Test Report | 2025-08-27 | PDF 1.2 MB |
| Attachment for 4G-1 | Test Report | 2025-08-27 | PDF 5.4 MB |
| Attachment for 4G-10 | Test Report | 2025-08-27 | PDF 5.5 MB |
| Attachment for 4G-11 | Test Report | 2025-08-27 | PDF 5.5 MB |
| Attachment for 4G-12 | Test Report | 2025-08-27 | PDF 4.2 MB |
| Attachment for 4G-2 | Test Report | 2025-08-27 | PDF 5.4 MB |
| Attachment for 4G-3 | Test Report | 2025-08-27 | PDF 5.4 MB |
| Attachment for 4G-4 | Test Report | 2025-08-27 | PDF 5.5 MB |
| Attachment for 4G-5 | Test Report | 2025-08-27 | PDF 5.4 MB |
| Attachment for 4G-6 | Test Report | 2025-08-27 | PDF 5.5 MB |
| Attachment for 4G-7 | Test Report | 2025-08-27 | PDF 5.5 MB |
| Attachment for 4G-8 | Test Report | 2025-08-27 | PDF 5.4 MB |
| Attachment for 4G-9 | Test Report | 2025-08-27 | PDF 5.5 MB |
| Attachment for 5GWIFI_1 | Test Report | 2025-08-27 | PDF 5.5 MB |
| Attachment for 5GWIFI_2 | Test Report | 2025-08-27 | PDF 5.4 MB |
| Attachment for 5GWIFI_3 | Test Report | 2025-08-27 | PDF 1.3 MB |
| 2.4GWIFI 1 | Test Report | 2025-08-26 | PDF 5.4 MB |
| 2.4GWIFI 2 | Test Report | 2025-08-26 | PDF 2.9 MB |
| BLE | Test Report | 2025-08-26 | PDF 4.2 MB |
| EDR 1 | Test Report | 2025-08-26 | PDF 5.4 MB |
| EDR 2 | Test Report | 2025-08-26 | PDF 2.5 MB |
| 2.911 (d)(5)(i)CertificationEquipmentTypev1.2 | Attestation Statements | 2025-08-27 | PDF 156.3 KB |
| 2.911 (d)(5)(ii)CertificiationApplicantv1.2 | Attestation Statements | 2025-08-27 | PDF 140.3 KB |
| 2.911 (d)(5)(ii)CertificiationApplicantv1.3 | Attestation Statements | 2025-08-27 | PDF 140.3 KB |
| 2.911 (d)(7)USAgentforServiceofProcessv1.4 | Attestation Statements | 2025-08-27 | PDF 130.1 KB |
| 2.911 (d)(5)(ii)CertificationApplicantv1.3 | Attestation Statements | 2025-08-26 | PDF 140.3 KB |
| 2.911 (d)(7)USAgentforServiceofProcessv1.3 | Attestation Statements | 2025-08-26 | PDF 130.1 KB |
| FCC Short & Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 2025-08-27 | PDF 81.4 KB |
| FCC Software Configuration Control Declaration | Cover Letter(s) | 2025-08-27 | PDF 80.7 KB |
| Letter of Authorization Rev 2.0 | Cover Letter(s) | 2025-08-27 | PDF 101.6 KB |
| Letter of Authorization Rev2.0 | Cover Letter(s) | 2025-08-26 | PDF 101.6 KB |
| SAR_1 | RF Exposure Info | 2025-08-27 | PDF 5.5 MB |
| SAR_2 | RF Exposure Info | 2025-08-27 | PDF 5.4 MB |
| SAR_3 | RF Exposure Info | 2025-08-27 | PDF 5.2 MB |
| SAR_4 | RF Exposure Info | 2025-08-27 | PDF 5.4 MB |
| SAR_5 | RF Exposure Info | 2025-08-27 | PDF 5.5 MB |
| SAR_6 | RF Exposure Info | 2025-08-27 | PDF 332.8 KB |
| Block Metadata only | Block Diagram | PDF 224.9 KB | |
| SCH Metadata only | Schematics | PDF 1.4 MB | |
| Operation Description Metadata only | Operational Description | PDF 158.8 KB | |
| Operational Description Metadata only | Operational Description | PDF 158.8 KB | |
| Operational description Metadata only | Operational Description | PDF 158.8 KB | |
| FCC Software Security Requirements for UNII devices Metadata only | SDR Software/Security Info. | PDF 254.3 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 178 KB | |
| Tune up procedure Metadata only | Parts List/Tune Up Info | PDF 1.2 MB |
Application Information
| Application ID | PYIAwGDh3HnZjy96U0/mRw== |
|---|---|
| Final Action Date | 2025-08-27 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0037191798 |
| Model | IV-4G-1 |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Northlight 4G |
| Responsible Party | Paul Tam, manager, paul@intellidt.com |
| Technical Contact | INTELLI GROUP, paul@intellidt.com |
| Test Firm | Alex Li, Shenzhen NTEK Testing Technology Co., Ltd., certification@ntek.org.cn |
| TCB Email | certification@micomlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 02/23/2026 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, hotspot, and simultaneous transmission use conditions is 0.80W/kg, 0.39W/kg, 0.39W/kg and 1.45W/kg respectively. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| PYIAwGDh3HnZjy96U0/mRw== | 2025-08-27 | Original Equipment |
| 1IB7k2oBKjkX1HEPupKPvQ== | 2025-08-27 | Original Equipment |
| IvfeAoQ0fsZuPShQrFla8w== | 2025-08-26 | Original Equipment |
| 3juzlPDcjeXyHQF2F/wfqA== | 2025-08-26 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Rules | Grant Notes |
|---|---|---|---|---|
| 673-688 MHz | 0.11668 | 0.019767ppm | ||
| 673-688 MHz | 0.11402 | 0.020578ppm | ||
| 704-711 MHz | 0.129718 | 0.013506ppm | ||
| 704-711 MHz | 0.125893 | 0.011596ppm | ||
| 709-711 MHz | 0.137721 | 0.014132ppm | ||
| 709-711 MHz | 0.11695 | 0.01359ppm | ||
| 819 MHz | 0.1194 | 0.010208ppm | ||
| 819 MHz | 0.11695 | 0.010948ppm | ||
| 826.4-846.6 MHz | 0.290402 | 0.025323ppm | ||
| 829-844 MHz | 0.129718 | 0.008115ppm | ||
| 829-844 MHz | 0.11508 | 0.013537ppm | ||
| 831.5-841.5 MHz | 0.09977 | 0.01292ppm | ||
| 831.5-841.5 MHz | 0.10046 | 0.01387ppm | ||
| 1712.4-1752.6 MHz | 0.206063 | 0.011966ppm | ||
| 1720-1745 MHz | 0.121619 | 0.005521ppm | ||
| 1720-1745 MHz | 0.10666 | 0.0057ppm | ||
| 1720-1770 MHz | 0.118032 | 0.00806ppm | ||
| 1720-1770 MHz | 0.097949 | 0.008136ppm | ||
| 1850.2-1909.8 MHz | 1.111732 | 0.012771ppm | 1.111732 | |
| 1850.2-1909.8 MHz | 0.430527 | 0.012037ppm | ||
| 1852.4-1907.6 MHz | 0.271019 | 0.011441ppm | ||
| 1860-1905 MHz | 0.11749 | 0.009562ppm | ||
| 1860-1905 MHz | 0.121619 | 0.005136ppm | ||
| 1860-1900 MHz | 0.12388 | 0.007784ppm | ||
| 1860-1900 MHz | 0.10617 | 0.005125ppm | ||
| 2402-2480 MHz | 0.0023990 | CC | ||
| 2402-2480 MHz | 0.000538 | CC | ||
| 2412-2462 MHz | 0.035727 | CC | ||
| 5180-5240 MHz | 0.029242 | CC | ||
| 5745-5825 MHz | 0.020845 | CC |
Grants
TCB Grant - Application PYIAwGDh3HnZjy96U0/mRw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 08/27/2025 Application Dated: 08/27/2025 |
| INTELLI GROUP |
| #200-3071 No.5 Road |
| Richmond, BC, V6X 2T4 Canada |
| Attention: Paul Tam , manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BQHGIV-4G-1 |
| Name of Grantee: | INTELLI GROUP |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Northlight 4G |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.029242 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.020845 |
| Output power listed is conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, hotspot, and simultaneous transmission use conditions is 0.80W/kg, 0.39W/kg, 0.39W/kg and 1.45W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application IvfeAoQ0fsZuPShQrFla8w==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 08/26/2025 Application Dated: 08/26/2025 |
| INTELLI GROUP |
| #200-3071 No.5 Road |
| Richmond, BC, V6X 2T4 Canada |
| Attention: Paul Tam , manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BQHGIV-4G-1 |
| Name of Grantee: | INTELLI GROUP |
| Equipment Class: | Digital Transmission System |
| Notes: | Northlight 4G |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.000538 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.035727 |
| Output power listed is conducted power. This device contains 20 and 40 MHz signal bandwidth. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, hotspot, and simultaneous transmission use conditions is 0.99W/kg, 0.31W/kg, 0.40W/kg and 1.45W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application 3juzlPDcjeXyHQF2F/wfqA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 08/26/2025 Application Dated: 08/26/2025 |
| INTELLI GROUP |
| #200-3071 No.5 Road |
| Richmond, BC, V6X 2T4 Canada |
| Attention: Paul Tam , manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BQHGIV-4G-1 |
| Name of Grantee: | INTELLI GROUP |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Northlight 4G |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.002399 |
| Output power listed is conducted power. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, hotspot, and simultaneous transmission use conditions is 0.13W/kg, 0.03W/kg, 0.04W/kg and 1.45W/kg respectively. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application 1IB7k2oBKjkX1HEPupKPvQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 08/27/2025 Application Dated: 08/27/2025 |
| INTELLI GROUP |
| #200-3071 No.5 Road |
| Richmond, BC, V6X 2T4 Canada |
| Attention: Paul Tam , manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BQHGIV-4G-1 |
| Name of Grantee: | INTELLI GROUP |
| Equipment Class: | PCS Licensed Transmitter held to ear |
| Notes: | Northlight 4G |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 1.506607 | 0.013439 PM | 252KGXW | |
| 22H | 824.2 - 848.8 | 0.598412 | 0.015483 PM | 251KG7W | |
| 24E | 1850.2 - 1909.8 | 1.111732 | 0.012771 PM | 255KGXW | |
| 24E | 1850.2 - 1909.8 | 0.430527 | 0.012037 PM | 267KG7W | |
| 24E | 1852.4 - 1907.6 | 0.271019 | 0.011441 PM | 4M19F9W | |
| 27 | 1712.4 - 1752.6 | 0.206063 | 0.011966 PM | 4M20F9W | |
| 22H | 826.4 - 846.6 | 0.290402 | 0.025323 PM | 4M21F9W | |
| 24E | 1860.0 - 1900.0 | 0.12388 | 0.007784 PM | 17M9G7D | |
| 24E | 1860.0 - 1900.0 | 0.10617 | 0.005125 PM | 17M9W7D | |
| 27 | 1720.0 - 1745.0 | 0.121619 | 0.005521 PM | 17M9G7D | |
| 27 | 1720.0 - 1745.0 | 0.10666 | 0.0057 PM | 17M9W7D | |
| 22H | 829.0 - 844.0 | 0.129718 | 0.008115 PM | 9M02G7D | |
| 22H | 829.0 - 844.0 | 0.11508 | 0.013537 PM | 9M00W7D | |
| 27 | 704.0 - 711.0 | 0.129718 | 0.013506 PM | 9M03G7D | |
| 27 | 704.0 - 711.0 | 0.125893 | 0.011596 PM | 9M01W7D | |
| 27 | 709.0 - 711.0 | 0.137721 | 0.014132 PM | 8M99G7D | |
| 27 | 709.0 - 711.0 | 0.11695 | 0.01359 PM | 8M98W7D | |
| 24E | 1860.0 - 1905.0 | 0.11749 | 0.009562 PM | 17M9G7D | |
| 24E | 1860.0 - 1905.0 | 0.121619 | 0.005136 PM | 17M9W7D | |
| 90 | 819.0 - 819.0 | 0.1194 | 0.010208 PM | 8M96G7D | |
| 90 | 819.0 - 819.0 | 0.11695 | 0.010948 PM | 8M97W7D | |
| 22H | 831.5 - 841.5 | 0.09977 | 0.01292 PM | 13M4G7D | |
| 22H | 831.5 - 841.5 | 0.10046 | 0.01387 PM | 13M5W7D | |
| 27 | 1720.0 - 1770.0 | 0.118032 | 0.00806 PM | 18M0G7D | |
| 27 | 1720.0 - 1770.0 | 0.097949 | 0.008136 PM | 18M0W7D | |
| 27 | 673.0 - 688.0 | 0.11668 | 0.019767 PM | 17M9G7D | |
| 27 | 673.0 - 688.0 | 0.11402 | 0.020578 PM | 17M9W7D |
| Power output listed is ERP for frequencies below 1GHz and EIRP for frequencies above 1GHz. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 10mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for head, body-worn accessory, hotspot, and simultaneous transmission use conditions is 0.46W/kg, 1.16W/kg, 1.16W/kg and 1.45W/kg respectively. This device also contains functions that are not operational in U.S. Territories. This filing is only applicable for US operations. |