FCC ID 2BRPK-MDL100

Wireless smart lock

by MAYON ELECTRONIC TECHNOLOGY CO.,LTD

Grantee Code: 2BRPK   Product Code: MDL100
Latest application date: 2025-12-17

FCC ID Device Details

FCC ID2BRPK-MDL100
Mirrorsfcc.id | gov | fccid.ai
Grantee Code2BRPK
Product CodeMDL100
Applicant BusinessMAYON ELECTRONIC TECHNOLOGY CO.,LTD 🇨🇳
Related Domains mayoncn.com
Equipment ClassWireless smart lock
Test FirmShenzhen GUOREN Certification Technology Service C

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2025-12-17
433.92 MHzOriginal Equipment2025-12-17

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2025-12-17PDF 2.1 MB
Internal photoInternal Photos2025-12-17PDF 2.7 MB
External photoExternal Photos2025-12-17PDF 620 KB
Label and label locationID Label/Location Info2025-12-17PDF 140.3 KB
Test Setup PhotosTest Setup Photos2025-12-17PDF 389.4 KB
Antenna Specification WIFITest Report2025-12-17PDF 892.4 KB
Antenna specification 433Test Report2025-12-17PDF 603.9 KB
GRCTR250904041-01-WIFI 2.4G-PART 1Test Report2025-12-17PDF 4.7 MB
GRCTR250904041-01-WIFI 2.4G-PART 2Test Report2025-12-17PDF 4.5 MB
GRCTR250904041-02-433Test Report2025-12-17PDF 2.1 MB
USA-CoveredEquipmentLetter-Combined_V1.1Attestation Statements2025-12-17PDF 133.2 KB
USA-LocalRepLetter_V1.1-2BRPK-MDL100Attestation Statements2025-12-17PDF 95.4 KB
Declaration Letter of Model DifferenceCover Letter(s)2025-12-17PDF 90.9 KB
FCC Declaration of Disable WLAN Channel 12 and 13Cover Letter(s)2025-12-17PDF 111.5 KB
USA-ConfidentialityRequestLetter_V0.1Cover Letter(s)2025-12-17PDF 116.1 KB
GRCTR250904041-04-RF ExposureRF Exposure Info2025-12-17PDF 398.8 KB
Block diagram Metadata onlyBlock DiagramPDF 175.7 KB
Schematic Metadata onlySchematicsPDF 1.3 MB
Schematic Module Metadata onlySchematicsPDF 138.6 KB
Operation Description Metadata onlyOperational DescriptionPDF 171.8 KB
USA-DueDigilenceLetter_V0.1 Metadata onlyOperational DescriptionPDF 167.4 KB

Application Information

Application IDDqooaaXnJ0XA2YYzkK+IEQ==
Final Action Date2025-12-17
Application PurposeOriginal Equipment
Applicant FRN0037404795
ModelMDL100
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device DescriptionWireless smart lock
Responsible PartyLandy Lin, lin@mayoncn.com , 0756-3626608
Non-Technical ContactCindy Wu, HOORAY INDUSTRY LLC, cindynewhope@gmail.com , (626) 910-5808
Test FirmSam Wang, Shenzhen GUOREN Certification Technology Service C, sam.wang@grcert.com , 86-755-23408306
TCB Emailo.kneip@kl-certification.de
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Modular EquipmentDoes not apply
Composite DeviceYes
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo

Applications

Application IDDatePurpose
DqooaaXnJ0XA2YYzkK+IEQ==2025-12-17Original Equipment
DpustFDGyiMO3hoeGE+m9A==2025-12-17Original Equipment

Equipment Authorization

FrequencyOutputRules
2412-2462 MHz0.217815C
433.92 MHz15.231

Grants

TCB Grant - Application DqooaaXnJ0XA2YYzkK+IEQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  KL-Certification GmbH
Heinrich-Hertz-Allee 7
St. Ingbert, 66386
Germany
Date of Grant: 12/17/2025

Application Dated: 12/17/2025
MAYON ELECTRONIC TECHNOLOGY CO.,LTD
Area A01, 4th Floor, Building 1, No. 15,
Pingbei 2nd Road, Nanping, Xiangzhou District,
Zhuhai,
China
 
Attention: Landy Lin , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BRPK-MDL100
Name of Grantee:  MAYON ELECTRONIC TECHNOLOGY CO.,LTD
Equipment Class: Digital Transmission System
Notes: Wireless smart lock
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 2412.0  -  2462.0 0.2178  

Output Power listed is peak conducted. This device supports 802.11b, 802.11g and 802.11n with a 20 MHz and 40 MHz bandwidth mode. RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

TCB Grant - Application DpustFDGyiMO3hoeGE+m9A==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  KL-Certification GmbH
Heinrich-Hertz-Allee 7
St. Ingbert, 66386
Germany
Date of Grant: 12/17/2025

Application Dated: 12/17/2025
MAYON ELECTRONIC TECHNOLOGY CO.,LTD
Area A01, 4th Floor, Building 1, No. 15,
Pingbei 2nd Road, Nanping, Xiangzhou District,
Zhuhai,
China
 
Attention: Landy Lin , CEO

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  2BRPK-MDL100
Name of Grantee:  MAYON ELECTRONIC TECHNOLOGY CO.,LTD
Equipment Class: Part 15 Security/Remote Control Transmitter
Notes: Wireless smart lock
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15.231 433.92  -  433.92  

RF exposure compliance is addressed for 1.1310 and 2.1091 MPE limits. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons. End Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.