FCC ID 2BTEQEFORLINKS02
EforLink Terminal Device
by Eforthink Technology Co., Ltd.
Grantee Code: 2BTEQ Product Code: EFORLINKS02
Latest application date: 2026-01-16
FCC ID Device Details
| FCC ID | 2BTEQEFORLINKS02 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2BTEQ |
| Product Code | EFORLINKS02 |
| Applicant Business | Eforthink Technology Co., Ltd. 🇨🇳 |
| Related Domains | |
| Equipment Class | EforLink Terminal Device |
| Test Firm | Shenzhen Morlab Communications Technology Co. Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 7987.2 MHz | Original Equipment | 2026-01-16 |
| 2402-2480 MHz | Original Equipment | 2026-01-16 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| UM | Users Manual | 2026-06-29 | PDF 964.7 KB |
| Internal Photos | Internal Photos | 2026-06-29 | PDF 708.5 KB |
| External Photos | External Photos | 2026-06-29 | PDF 817.5 KB |
| LABEL & Location | ID Label/Location Info | 2026-01-16 | PDF 605.5 KB |
| SAR_Annex B Test Setup Photos | Test Setup Photos | 2026-06-29 | PDF 347.6 KB |
| Test Setup Photos_DTS | Test Setup Photos | 2026-06-29 | PDF 654.6 KB |
| Test Setup Photos_UWB | Test Setup Photos | 2026-06-29 | PDF 657.2 KB |
| Antenna_SPEC-BT | Test Report | 2026-01-16 | PDF 1.1 MB |
| Antenna_SPEC-UWB | Test Report | 2026-01-16 | PDF 921.3 KB |
| SZ25090117W01_Eforthink_EFORLINKS02_BLE_DTS | Test Report | 2026-01-16 | PDF 2.3 MB |
| SZ25090117W02_Eforthink_EFORLINKS02_UWB | Test Report | 2026-01-16 | PDF 2.2 MB |
| Attestation_COVERED_EQUIPMENT | Attestation Statements | 2026-01-16 | PDF 271.3 KB |
| Attestation_Letter_US_AGENT | Attestation Statements | 2026-01-16 | PDF 395.9 KB |
| Confidentiality | Cover Letter(s) | 2026-01-16 | PDF 400.9 KB |
| POA | Cover Letter(s) | 2026-01-16 | PDF 293.4 KB |
| Annex C Plots of System Performance Check | RF Exposure Info | 2026-01-16 | PDF 291.7 KB |
| Annex D Plots of Maximum PD Test Results | RF Exposure Info | 2026-01-16 | PDF 308.4 KB |
| Annex E Conducted Power | RF Exposure Info | 2026-01-16 | PDF 275.1 KB |
| Annex F1 DASY Calibration Certificate_EUmmWV4 SN9602 | RF Exposure Info | 2026-01-16 | PDF 5.3 MB |
| Annex F2 DASY Calibration Certificate_5G Source 10GHz SN1019 | RF Exposure Info | 2026-01-16 | PDF 479.3 KB |
| SZ25090117S01_Eforthink_EFORLINKS02_FCC SAR & PD | RF Exposure Info | 2026-01-16 | PDF 1.9 MB |
| Block diagram Metadata only | Block Diagram | PDF 60.3 KB | |
| schematic Metadata only | Schematics | PDF 902.1 KB | |
| OP Metadata only | Operational Description | PDF 124.4 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 88.1 KB | |
| Tune-up Metadata only | Parts List/Tune Up Info | PDF 93 KB |
Application Information
| Application ID | sTQ0g3rgGhiU//5v/srjCQ== |
|---|---|
| Final Action Date | 2026-01-16 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0037694288 |
| Model | EFORLINKS02 |
| Frequency Range | 7987.2 MHz |
| Equipment Class | UWB - Ultra Wideband Transmitter |
| Device Description | EforLink Terminal Device |
| Responsible Party | Zhengbao Ma, mazhengbao@everhigh.com.cn |
| Non-Technical Contact | Tim Payne, FCC US Agent, LLC, Support@FCCUSAgent.com |
| Test Firm | Mr. Su Feng, Shenzhen Morlab Communications Technology Co. Ltd., Zx.sun@morlab.cn |
| TCB Email | bentje.holger@phoenix-testlab.de |
| TCB Scope | A2: Low Power Transmitters (except Spread Spectrum) and radar detectors operating above 1 GHz |
| Short-Term Confidentiality | Yes |
| Long-Term Confidentiality | Yes |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| sTQ0g3rgGhiU//5v/srjCQ== | 2026-01-16 | Original Equipment |
| OlsiCegVSRJbHzoj5zPLBg== | 2026-01-16 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application sTQ0g3rgGhiU//5v/srjCQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 01/16/2026 Application Dated: 12/30/2025 |
| Eforthink Technology Co., Ltd. |
| Units 904,905,906, 9/Floor & Unit 1007, 10/Floor |
| Building 1, 898 Baicao Road, Gaoxin West District |
| Chengdu City, Sichuan Province, China |
| Attention: Zhengbao Ma , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BTEQEFORLINKS02 |
| Name of Grantee: | Eforthink Technology Co., Ltd. |
| Equipment Class: | Ultra Wideband Transmitter |
| Notes: | EforLink Terminal Device |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15F | 6489.6 - 6489.6 | |||
| CC | 15F | 7987.2 - 7987.2 |
| This device has integrated DTS and UWB transmitters certified under the same FCC ID. SAR compliance for body-worn operating configurations is limited to the belt- clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 2 mm separation between the device and the user's body. The highest reported power density is 0.53 W/m2. UWB devices may not be employed for the operation of toys. Operation onboard an aircraft or a satellite is prohibited. Antennas mounted on outdoor structures such the outside of a building or on a telephone pole, or any fixed outdoors infrastructure are prohibited. This device is approved under Part 15.519 for handheld use. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application OlsiCegVSRJbHzoj5zPLBg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 01/16/2026 Application Dated: 12/30/2025 |
| Eforthink Technology Co., Ltd. |
| Units 904,905,906, 9/Floor & Unit 1007, 10/Floor |
| Building 1, 898 Baicao Road, Gaoxin West District |
| Chengdu City, Sichuan Province, China |
| Attention: Zhengbao Ma , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BTEQEFORLINKS02 |
| Name of Grantee: | Eforthink Technology Co., Ltd. |
| Equipment Class: | Digital Transmission System |
| Notes: | EforLink Terminal Device |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.00146 |
| Output power is maximum peak conducted. This device has integrated DTS and UWB transmitters certified under the same FCC ID. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |