FCC ID 2BTHP-2-WF002-V01
Dual-Band WiFi Module
by Shenzhen Peninsula Medical Group
Grantee Code: 2BTHP Product Code: 2WF002V01
Latest application date: 2026-09-06
FCC ID Device Details
| FCC ID | 2BTHP-2-WF002-V01 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2BTHP |
| Product Code | 2WF002V01 |
| Applicant Business | Shenzhen Peninsula Medical Group 🇨🇳 |
| Related Domains | |
| Equipment Class | Dual-Band WiFi Module |
| Test Firm | DEKRA TESTING SERVICES (ANHUI) CO., LTD. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2026-09-06 |
| 5745-5825 MHz | Original Equipment | 2026-09-06 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| Label | ID Label/Location Info | 2026-09-06 | PDF 850.1 KB |
| Label Location | ID Label/Location Info | 2026-09-06 | PDF 13.7 KB |
| 15.247 2.4G WIFI report part1 | Test Report | 2026-09-06 | PDF 5.7 MB |
| 15.247 2.4G WIFI report part2 | Test Report | 2026-09-06 | PDF 5.3 MB |
| 15.407 report part1 | Test Report | 2026-09-06 | PDF 5.8 MB |
| 15.407 report part2 | Test Report | 2026-09-06 | PDF 5.8 MB |
| 15.407 report part3 | Test Report | 2026-09-06 | PDF 5.8 MB |
| 15.407 report part4 | Test Report | 2026-09-06 | PDF 5.8 MB |
| Antenna Specification | Test Report | 2026-09-06 | PDF 1.8 MB |
| Attestation Statements Part 2.911 i ii | Attestation Statements | 2026-09-06 | PDF 237.5 KB |
| Attestation Statements US agent Letter | Attestation Statements | 2026-09-06 | PDF 236.1 KB |
| Attestation Statements US agent for service of process | Attestation Statements | 2026-09-06 | PDF 236.1 KB |
| Confidentiality Letter | Cover Letter(s) | 2026-09-06 | PDF 207 KB |
| Modular Approval Letter | Cover Letter(s) | 2026-09-06 | PDF 273.6 KB |
| POA | Cover Letter(s) | 2026-09-06 | PDF 103.8 KB |
| modular Approval letter | Cover Letter(s) | 2026-09-06 | PDF 273.6 KB |
| RF Exposure | RF Exposure Info | 2026-09-06 | PDF 534 KB |
| UserManual Metadata only | Users Manual | 2027-03-06 | PDF 263.1 KB |
| Internal Photos Metadata only | Internal Photos | 2027-03-06 | PDF 563.1 KB |
| External Photos Metadata only | External Photos | 2027-03-06 | PDF 3.6 MB |
| Test Setup Photos Metadata only | Test Setup Photos | 2027-03-06 | PDF 1.2 MB |
| Blcok Diagram Metadata only | Block Diagram | PDF 31 KB | |
| Schematics Metadata only | Schematics | PDF 120.9 KB | |
| Operational Description Metadata only | Operational Description | PDF 156.9 KB | |
| Software Security Operational Description Metadata only | SDR Software/Security Info. | PDF 269.1 KB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 20.3 KB |
Application Information
| Application ID | p3+R/7TeGH5WXKG6F6WPcA== |
|---|---|
| Final Action Date | 2026-09-06 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0037710530 |
| Model | 2-WF002-V01 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | Dual-Band WiFi Module |
| Responsible Party | Sudi Zhang, zhangchunyan@peninsula-med.com |
| Non-Technical Contact | Yingying Huang, Boston Aesthetics INC, bsnaesthetics@gmail.com |
| Test Firm | Derek Feng, DEKRA TESTING SERVICES (ANHUI) CO., LTD., derek.feng@dekra.com |
| TCB Email | CB@industrial-ia.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | Yes |
| Long-Term Confidentiality | Yes |
| Modular Equipment | Limited Single Modular Approval |
| Composite Device | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| p3+R/7TeGH5WXKG6F6WPcA== | 2026-09-06 | Original Equipment |
| dkfdQg2IMIOYUi1ECq9EfA== | 2026-09-06 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application p3+R/7TeGH5WXKG6F6WPcA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
IIA Lab Services, LLC 13146 NW 86th Drive Suite 400 Alachua, FL 32615 |
Date of Grant: 09/06/2026 Application Dated: 08/25/2026 |
| Shenzhen Peninsula Medical Group |
| 3F Block B,3F Block A,Building F2,Changfeng |
| Liuxian 3rd Road, 68 Xinan Street, Baoan District |
| Shenzhen, 518000 China |
| Attention: Sudi Zhang , Director of Regulatory Affairs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BTHP-2-WF002-V01 |
| Name of Grantee: | Shenzhen Peninsula Medical Group |
| Equipment Class: | Digital Transmission System |
| Notes: | Dual-Band WiFi Module |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2412.0 - 2462.0 | 0.16 |
| Output power listed is conducted. Limited Modular Approval for mobile RF Exposure conditions. The module antenna(s) must be installed to meet the RF exposure compliance separation distance of 20 cm from all persons and any additional testing and authorization process as required. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. Approved for OEM integration only. The grantee must provide OEM integrators with installation and operating instructions for satisfying FCC multi-transmitter product guidelines. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end-user has no manual instructions to remove or install the device. This device supports 20, and 40 MHz modes. This Module is limited, requiring the host integrator to perform additional verification testing as provided by the manufacturer's integration instructions for: 1. Module has no shield, 2 No onboard power regulation. This module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. Any changes must be communicated to Shenzhen Peninsula Medical Group to arrange for Change in ID and Permissive Change applications. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application dkfdQg2IMIOYUi1ECq9EfA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
IIA Lab Services, LLC 13146 NW 86th Drive Suite 400 Alachua, FL 32615 |
Date of Grant: 09/06/2026 Application Dated: 08/25/2026 |
| Shenzhen Peninsula Medical Group |
| 3F Block B,3F Block A,Building F2,Changfeng |
| Liuxian 3rd Road, 68 Xinan Street, Baoan District |
| Shenzhen, 518000 China |
| Attention: Sudi Zhang , Director of Regulatory Affairs |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BTHP-2-WF002-V01 |
| Name of Grantee: | Shenzhen Peninsula Medical Group |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Dual-Band WiFi Module |
| Modular Type: | Limited Single Modular |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.028 | ||
| CC | 15E | 5260.0 - 5320.0 | 0.032 | ||
| CC | 15E | 5500.0 - 5700.0 | 0.047 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.043 |
| Output power listed is conducted. Limited Modular Approval for mobile RF Exposure conditions. The module antenna(s) must be installed to meet the RF exposure compliance separation distance of 20 cm from all persons and any additional testing and authorization process as required. Co-location of this module with other transmitters that operate simultaneously are required to be evaluated using the FCC multi-transmitter procedures. Approved for OEM integration only. The grantee must provide OEM integrators with installation and operating instructions for satisfying FCC multi-transmitter product guidelines. This grant is valid only when the device is sold to OEM integrators and the OEM integrators are instructed to ensure that the end-user has no manual instructions to remove or install the device. This device supports 20, 40, and 80 MHz modes. This Module is limited, requiring the host integrator to perform additional verification testing as provided by the manufacturer's integration instructions for: 1. Module has not shield, 2 No onboard power regulation. This module can only be used with a host antenna circuit trace layout design in strict compliance with the OEM instructions provided. Any changes must be communicated to Shenzhen Peninsula Medical Group to arrange for Change in ID and Permissive Change applications. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |