FCC ID 2BWMS-L5-5B-2006
Cell Phone Signal Booster
by Light Folding Science and Technology Co., Limited
Grantee Code: 2BWMS Product Code: L55B2006
Latest application date: 2026-08-19
FCC ID Device Details
| FCC ID | 2BWMS-L5-5B-2006 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2BWMS |
| Product Code | L55B2006 |
| Applicant Business | Light Folding Science and Technology Co., Limited 🇨🇳 |
| Equipment Class | Cell Phone Signal Booster |
| Test Firm | Dongguan Yaxu (AiT) Technology Limited |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2110-2155 MHz | Original Equipment | 2026-08-19 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2026-08-19 | PDF 2.1 MB |
| Internal photo | Internal Photos | 2026-08-19 | PDF 2.6 MB |
| External photo | External Photos | 2026-08-19 | PDF 2.4 MB |
| label and label location | ID Label/Location Info | 2026-08-19 | PDF 283.4 KB |
| Test setup photos_B2W | Test Setup Photos | 2026-08-19 | PDF 1 MB |
| AiTDG-260730002FW1_FCC Test Report_Part 20_Part1 | Test Report | 2026-08-19 | PDF 5.5 MB |
| AiTDG-260730002FW1_FCC Test Report_Part 20_Part2 | Test Report | 2026-08-19 | PDF 5.6 MB |
| AiTDG-260730002FW1_FCC Test Report_Part 20_Part3 | Test Report | 2026-08-19 | PDF 6 MB |
| AiTDG-260730002FW1_FCC Test Report_Part 20_Part4 | Test Report | 2026-08-19 | PDF 5.6 MB |
| AiTDG-260730002FW1_FCC Test Report_Part 20_Part5 | Test Report | 2026-08-19 | PDF 5.8 MB |
| AiTDG-260730002FW1_FCC Test Report_Part 20_Part6 | Test Report | 2026-08-19 | PDF 1.1 MB |
| USA-CoveredEquipmentLetter-Combined_V1.1 | Attestation Statements | 2026-08-19 | PDF 124.2 KB |
| Us agent-2BWMS-L5-5B-2006 | Attestation Statements | 2026-08-19 | PDF 121.8 KB |
| USA-ConfidentialityRequestLetter_V0.1 | Cover Letter(s) | 2026-08-19 | PDF 106.6 KB |
| AiTDG-260730002FW2_FCC RF EXPOSURE | RF Exposure Info | 2026-08-19 | PDF 203.8 KB |
| Block diagram Metadata only | Block Diagram | PDF 221 KB | |
| Schematic Metadata only | Schematics | PDF 2.6 MB | |
| Operation Metadata only | Operational Description | PDF 59.8 KB | |
| USA-DueDigilenceLetter_V0.1 Metadata only | Operational Description | PDF 64.7 KB | |
| Part list Metadata only | Parts List/Tune Up Info | PDF 102.9 KB | |
| Tune Up Metadata only | Parts List/Tune Up Info | PDF 64.9 KB |
Application Information
| Application ID | /xeBkw1BpqfOIvNhtA4odg== |
|---|---|
| Final Action Date | 2026-08-19 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0038545018 |
| Model | L5-5B-2006 |
| Frequency Range | 2110-2155 MHz |
| Equipment Class | B2W - Part 20 Wideband Consumer Booster (CMRS) |
| Device Description | Cell Phone Signal Booster |
| Responsible Party | Wei Yang, Lightfolding1@gmail.com |
| Non-Technical Contact | Cindy Wu, HOORAY INDUSTRY LLC, cindynewhope@gmail.com |
| Test Firm | Coin Tang, Dongguan Yaxu (AiT) Technology Limited, info@aitek.org.cn |
| TCB Email | o.kneip@kl-certification.de |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| /xeBkw1BpqfOIvNhtA4odg== | 2026-08-19 | Original Equipment |
Equipment Authorization
| Frequency | Output | Tolerance | Emission | Rules |
|---|---|---|---|---|
| 1850-1915 MHz | 0.103 | Amp | GXW | 24E |
| 1850-1915 MHz | 0.103 | Amp | G7W | 24E |
| 1850-1915 MHz | 0.103 | Amp | F9W | 24E |
| 1850-1915 MHz | 0.103 | Amp | G7D | 24E |
| 1850-1915 MHz | 0.103 | Amp | W7D | 24E |
| 1930-1995 MHz | 0.0108 | Amp | GXW | 24E |
| 1930-1995 MHz | 0.0108 | Amp | G7W | 24E |
| 1930-1995 MHz | 0.0108 | Amp | F9W | 24E |
| 1930-1995 MHz | 0.0108 | Amp | G7D | 24E |
| 1930-1995 MHz | 0.0108 | Amp | W7D | 24E |
| 1710-1755 MHz | 0.0867 | Amp | GXW | 27 |
| 1710-1755 MHz | 0.0867 | Amp | G7W | 27 |
| 1710-1755 MHz | 0.0867 | Amp | F9W | 27 |
| 1710-1755 MHz | 0.0867 | Amp | G7D | 27 |
| 1710-1755 MHz | 0.0867 | Amp | W7D | 27 |
| 2110-2155 MHz | 0.0077 | Amp | GXW | 27 |
| 2110-2155 MHz | 0.0077 | Amp | G7W | 27 |
| 2110-2155 MHz | 0.0077 | Amp | F9W | 27 |
| 2110-2155 MHz | 0.0077 | Amp | G7D | 27 |
| 2110-2155 MHz | 0.0077 | Amp | W7D | 27 |
| 824-849 MHz | 0.0745 | Amp | GXW | 22H |
| 824-849 MHz | 0.0745 | Amp | G7W | 22H |
| 824-849 MHz | 0.0745 | Amp | F9W | 22H |
| 824-849 MHz | 0.0745 | Amp | G7D | 22H |
| 824-849 MHz | 0.0745 | Amp | W7D | 22H |
| 869-894 MHz | 0.0087 | Amp | GXW | 22H |
| 869-894 MHz | 0.0087 | Amp | G7W | 22H |
| 869-894 MHz | 0.0087 | Amp | F9W | 22H |
| 869-894 MHz | 0.0087 | Amp | G7D | 22H |
| 869-894 MHz | 0.0087 | Amp | W7D | 22H |
| 699-716 MHz | 0.082 | Amp | GXW | 27 |
| 699-716 MHz | 0.082 | Amp | G7W | 27 |
| 699-716 MHz | 0.082 | Amp | F9W | 27 |
| 699-716 MHz | 0.082 | Amp | G7D | 27 |
| 699-716 MHz | 0.082 | Amp | W7D | 27 |
| 729-746 MHz | 0.0095 | Amp | GXW | 27 |
| 729-746 MHz | 0.0095 | Amp | G7W | 27 |
| 729-746 MHz | 0.0095 | Amp | F9W | 27 |
| 729-746 MHz | 0.0095 | Amp | G7D | 27 |
| 729-746 MHz | 0.0095 | Amp | W7D | 27 |
| 777-787 MHz | 0.0787 | Amp | GXW | 27 |
| 777-787 MHz | 0.0787 | Amp | G7W | 27 |
| 777-787 MHz | 0.0787 | Amp | F9W | 27 |
| 777-787 MHz | 0.0787 | Amp | G7D | 27 |
| 777-787 MHz | 0.0787 | Amp | W7D | 27 |
| 746-756 MHz | 0.0091 | Amp | GXW | 27 |
| 746-756 MHz | 0.0091 | Amp | G7W | 27 |
| 746-756 MHz | 0.0091 | Amp | F9W | 27 |
| 746-756 MHz | 0.0091 | Amp | G7D | 27 |
| 746-756 MHz | 0.0091 | Amp | W7D | 27 |
Grants
TCB Grant - Application /xeBkw1BpqfOIvNhtA4odg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
KL-Certification GmbH Heinrich-Hertz-Allee 7 St. Ingbert, 66386 Germany |
Date of Grant: 08/19/2026 Application Dated: 08/19/2026 |
| Light Folding Science and Technology Co., Limited |
| Room D07, 8/F, Block 2, Kai Tak Factory Building, |
| 99 King Fuk Street, San Po Kong, Hong Kong |
| Hong Kong, China |
| Attention: Wei Yang , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BWMS-L5-5B-2006 |
| Name of Grantee: | Light Folding Science and Technology Co., Limited |
| Equipment Class: | Part 20 Wideband Consumer Booster (CMRS) |
| Notes: | Cell Phone Signal Booster |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 24E | 1850.0 - 1915.0 | 0.103 | Amp | GXW | |
| 24E | 1850.0 - 1915.0 | 0.103 | Amp | G7W | |
| 24E | 1850.0 - 1915.0 | 0.103 | Amp | F9W | |
| 24E | 1850.0 - 1915.0 | 0.103 | Amp | G7D | |
| 24E | 1850.0 - 1915.0 | 0.103 | Amp | W7D | |
| 24E | 1930.0 - 1995.0 | 0.0108 | Amp | GXW | |
| 24E | 1930.0 - 1995.0 | 0.0108 | Amp | G7W | |
| 24E | 1930.0 - 1995.0 | 0.0108 | Amp | F9W | |
| 24E | 1930.0 - 1995.0 | 0.0108 | Amp | G7D | |
| 24E | 1930.0 - 1995.0 | 0.0108 | Amp | W7D | |
| 27 | 1710.0 - 1755.0 | 0.0867 | Amp | GXW | |
| 27 | 1710.0 - 1755.0 | 0.0867 | Amp | G7W | |
| 27 | 1710.0 - 1755.0 | 0.0867 | Amp | F9W | |
| 27 | 1710.0 - 1755.0 | 0.0867 | Amp | G7D | |
| 27 | 1710.0 - 1755.0 | 0.0867 | Amp | W7D | |
| 27 | 2110.0 - 2155.0 | 0.0077 | Amp | GXW | |
| 27 | 2110.0 - 2155.0 | 0.0077 | Amp | G7W | |
| 27 | 2110.0 - 2155.0 | 0.0077 | Amp | F9W | |
| 27 | 2110.0 - 2155.0 | 0.0077 | Amp | G7D | |
| 27 | 2110.0 - 2155.0 | 0.0077 | Amp | W7D | |
| 22H | 824.0 - 849.0 | 0.0745 | Amp | GXW | |
| 22H | 824.0 - 849.0 | 0.0745 | Amp | G7W | |
| 22H | 824.0 - 849.0 | 0.0745 | Amp | F9W | |
| 22H | 824.0 - 849.0 | 0.0745 | Amp | G7D | |
| 22H | 824.0 - 849.0 | 0.0745 | Amp | W7D | |
| 22H | 869.0 - 894.0 | 0.0087 | Amp | GXW | |
| 22H | 869.0 - 894.0 | 0.0087 | Amp | G7W | |
| 22H | 869.0 - 894.0 | 0.0087 | Amp | F9W | |
| 22H | 869.0 - 894.0 | 0.0087 | Amp | G7D | |
| 22H | 869.0 - 894.0 | 0.0087 | Amp | W7D | |
| 27 | 699.0 - 716.0 | 0.082 | Amp | GXW | |
| 27 | 699.0 - 716.0 | 0.082 | Amp | G7W | |
| 27 | 699.0 - 716.0 | 0.082 | Amp | F9W | |
| 27 | 699.0 - 716.0 | 0.082 | Amp | G7D | |
| 27 | 699.0 - 716.0 | 0.082 | Amp | W7D | |
| 27 | 729.0 - 746.0 | 0.0095 | Amp | GXW | |
| 27 | 729.0 - 746.0 | 0.0095 | Amp | G7W | |
| 27 | 729.0 - 746.0 | 0.0095 | Amp | F9W | |
| 27 | 729.0 - 746.0 | 0.0095 | Amp | G7D | |
| 27 | 729.0 - 746.0 | 0.0095 | Amp | W7D | |
| 27 | 777.0 - 787.0 | 0.0787 | Amp | GXW | |
| 27 | 777.0 - 787.0 | 0.0787 | Amp | G7W | |
| 27 | 777.0 - 787.0 | 0.0787 | Amp | F9W | |
| 27 | 777.0 - 787.0 | 0.0787 | Amp | G7D | |
| 27 | 777.0 - 787.0 | 0.0787 | Amp | W7D | |
| 27 | 746.0 - 756.0 | 0.0091 | Amp | GXW | |
| 27 | 746.0 - 756.0 | 0.0091 | Amp | G7W | |
| 27 | 746.0 - 756.0 | 0.0091 | Amp | F9W | |
| 27 | 746.0 - 756.0 | 0.0091 | Amp | G7D | |
| 27 | 746.0 - 756.0 | 0.0091 | Amp | W7D |
| Power listed is conducted at antenna terminals. The antennas used with this signal booster must be installed to provide a separation distance of at least 20 cm from all persons. Users and installers must be provided with the antenna kitting and installation instructions and operating conditions for satisfying RF exposure compliance. This device is a Wideband Mobile Consumer Signal Booster authorized only for operation by and marketing to members of the general public for their personal use in accordance with the requirements of 47 CFR 20.21(a) and 20.21(g). The installation height of the antenna for AWS band (1700/2100 MHz) operations is limited to 10 meters above ground for compliance with 47 CFR 27.50. |