FCC ID 2BXZK-MX15
Smart Terminal
by Medix-Care UK Ltd
Grantee Code: 2BXZK Product Code: MX15
Latest application date: 2026-09-04
FCC ID Device Details
| FCC ID | 2BXZK-MX15 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2BXZK |
| Product Code | MX15 |
| Applicant Business | Medix-Care UK Ltd 🇬🇧 |
| Related Domains | |
| Equipment Class | Smart Terminal |
| Test Firm | Guangzhou LCS Compliance Testing Laboratory Ltd |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5745-5825 MHz | Original Equipment | 2026-09-04 |
| 2402-2480 MHz | Original Equipment | 2026-09-04 |
| 2412-2462 MHz | Original Equipment | 2026-09-04 |
| 13.56 MHz | Original Equipment | 2026-09-04 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2026-09-04 | PDF 965.4 KB |
| Internal photos part 1 | Internal Photos | 2026-09-04 | PDF 5.3 MB |
| Internal photos part 2 | Internal Photos | 2026-09-04 | PDF 1.2 MB |
| External photos | External Photos | 2026-09-04 | PDF 959.5 KB |
| Label and label location | ID Label/Location Info | 2026-09-04 | PDF 68.3 KB |
| Test setup photos | Test Setup Photos | 2026-09-04 | PDF 370.7 KB |
| Antenna information | Test Report | 2026-09-04 | PDF 1.3 MB |
| Appendix A test data BT part 1 | Test Report | 2026-09-04 | PDF 5.5 MB |
| Appendix A test data BT part 2 | Test Report | 2026-09-04 | PDF 3.2 MB |
| Appendix B test data BT LE | Test Report | 2026-09-04 | PDF 2.7 MB |
| Appendix C test data 2G4WLAN part 1 | Test Report | 2026-09-04 | PDF 5.3 MB |
| Appendix C test data 2G4WLAN part 2 | Test Report | 2026-09-04 | PDF 3.4 MB |
| Appendix D test data 5GWLAN band 1 part 1 | Test Report | 2026-09-04 | PDF 5.4 MB |
| Appendix D test data 5GWLAN band 1 part 2 | Test Report | 2026-09-04 | PDF 978.3 KB |
| Appendix E test data 5GWLAN band 3 | Test Report | 2026-09-04 | PDF 5.6 MB |
| Test Report 2G4WLAN | Test Report | 2026-09-04 | PDF 1.5 MB |
| Test Report 5GWLAN band 1 | Test Report | 2026-09-04 | PDF 1.4 MB |
| Test Report 5GWLAN band 3 | Test Report | 2026-09-04 | PDF 1.4 MB |
| Test Report BT | Test Report | 2026-09-04 | PDF 1.3 MB |
| Test Report BT LE | Test Report | 2026-09-04 | PDF 1.4 MB |
| Test Report NFC | Test Report | 2026-09-04 | PDF 1.7 MB |
| Agent attestation letter | Attestation Statements | 2026-09-04 | PDF 358.1 KB |
| Covered equipment letter | Attestation Statements | 2026-09-04 | PDF 253.6 KB |
| Due digilence letter | Attestation Statements | 2026-09-04 | PDF 248.7 KB |
| Confidentiality request letter | Cover Letter(s) | 2026-09-04 | PDF 257.1 KB |
| Letter of declaration disable cellular function by software | Cover Letter(s) | 2026-09-04 | PDF 109.6 KB |
| Letter of declaration disable channel 12 and 13 by software | Cover Letter(s) | 2026-09-04 | PDF 183.5 KB |
| Letter of declaration model difference | Cover Letter(s) | 2026-09-04 | PDF 108.9 KB |
| RF exposure evaluation | RF Exposure Info | 2026-09-04 | PDF 318.1 KB |
| Block diagram Metadata only | Block Diagram | PDF 420.6 KB | |
| Schematic Metadata only | Schematics | PDF 1.8 MB | |
| Letter of declaration unii device Metadata only | Operational Description | PDF 319.3 KB | |
| Letter of declaration unii device software configuration control Metadata only | Operational Description | PDF 150.8 KB | |
| Letter of declaration unii device software security requirements Metadata only | Operational Description | PDF 199.8 KB | |
| Operation description Metadata only | Operational Description | PDF 333 KB | |
| Software bill of material Metadata only | Operational Description | PDF 341.8 KB |
Application Information
| Application ID | zgCPmAAO6zxRRwsNqVHqgA== |
|---|---|
| Final Action Date | 2026-09-04 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0038835179 |
| Model | MX15 |
| Frequency Range | 5745-5825 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | Smart Terminal |
| Responsible Party | Warren Kressinger-Dunn, wkd@medix-care.co.uk |
| Non-Technical Contact | Cindy Wu, HOORAY INDUSTRY LLC, cindynewhope@gmail.com |
| Test Firm | Gavin Liang, Guangzhou LCS Compliance Testing Laboratory Ltd, gavin.liang@lcs-cert.com |
| TCB Email | o.kneip@kl-certification.de |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| zgCPmAAO6zxRRwsNqVHqgA== | 2026-09-04 | Original Equipment |
| KtsiYWZmSt4m9VapWLAbsA== | 2026-09-04 | Original Equipment |
| 2hDMaryXHNFvj1FlC5zj5A== | 2026-09-04 | Original Equipment |
| +UBC+7MjYbSvHSgUUJ3wNw== | 2026-09-04 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application zgCPmAAO6zxRRwsNqVHqgA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
KL-Certification GmbH Heinrich-Hertz-Allee 7 St. Ingbert, 66386 Germany |
Date of Grant: 09/04/2026 Application Dated: 09/04/2026 |
| Medix-Care UK Ltd |
| 5 Admirals Hard |
| Plymouth Devon, PL1 3RJ United Kingdom |
| Attention: Warren Kressinger-Dunn , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BXZK-MX15 |
| Name of Grantee: | Medix-Care UK Ltd |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | Smart Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15E | 5180.0 - 5240.0 | 0.0356 | ||
| CC | 15E | 5745.0 - 5825.0 | 0.0389 |
| Power listed is maximum average conducted output power. The device supports 20 MHz, 40 MHz and 80 MHz bandwidth modes as described in this filing. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. The device also contains NFC, BLE, 2.4GHz WLAN and Bluetooth transmitters. Device disable cellular function (2G/3G/4G) by software. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application KtsiYWZmSt4m9VapWLAbsA==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
KL-Certification GmbH Heinrich-Hertz-Allee 7 St. Ingbert, 66386 Germany |
Date of Grant: 09/04/2026 Application Dated: 09/04/2026 |
| Medix-Care UK Ltd |
| 5 Admirals Hard |
| Plymouth Devon, PL1 3RJ United Kingdom |
| Attention: Warren Kressinger-Dunn , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BXZK-MX15 |
| Name of Grantee: | Medix-Care UK Ltd |
| Equipment Class: | Part 15 Spread Spectrum Transmitter |
| Notes: | Smart Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0015 |
| Power listed is maximum peak conducted output power. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. The device also contains NFC, BLE, 2.4GHz WLAN and 5GHz WLAN transmitters. Device disable cellular function (2G/3G/4G) by software. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application 2hDMaryXHNFvj1FlC5zj5A==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
KL-Certification GmbH Heinrich-Hertz-Allee 7 St. Ingbert, 66386 Germany |
Date of Grant: 09/04/2026 Application Dated: 09/04/2026 |
| Medix-Care UK Ltd |
| 5 Admirals Hard |
| Plymouth Devon, PL1 3RJ United Kingdom |
| Attention: Warren Kressinger-Dunn , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BXZK-MX15 |
| Name of Grantee: | Medix-Care UK Ltd |
| Equipment Class: | Digital Transmission System |
| Notes: | Smart Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 2402.0 - 2480.0 | 0.0012 | ||
| CC | 15C | 2412.0 - 2462.0 | 0.0225 |
| Power listed is maximum conducted output power. This device supports both 20 MHz and 40 MHz bandwidth modes as described in this filing. The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. The device also contains NFC, Bluetooth and 5GHz WLAN transmitters. Device disable cellular function (2G/3G/4G) by software. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
TCB Grant - Application +UBC+7MjYbSvHSgUUJ3wNw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
KL-Certification GmbH Heinrich-Hertz-Allee 7 St. Ingbert, 66386 Germany |
Date of Grant: 09/04/2026 Application Dated: 09/04/2026 |
| Medix-Care UK Ltd |
| 5 Admirals Hard |
| Plymouth Devon, PL1 3RJ United Kingdom |
| Attention: Warren Kressinger-Dunn , |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2BXZK-MX15 |
| Name of Grantee: | Medix-Care UK Ltd |
| Equipment Class: | Part 15 Low Power Communication Device Transmitter |
| Notes: | Smart Terminal |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC | 15C | 13.56 - 13.56 |
| The product must be installed such that its antenna(s) can provide a separation distance of at least 20 cm from all persons and must not transmit simultaneously with any other transmitter, except in accordance with FCC multi-transmitter product procedures or as described in this filing. The device also contains Bluetooth, BLE, 2.4GHz WLAN and 5GHz WLAN transmitters. Device disable cellular function (2G/3G/4G) by software. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |