FCC ID Device Details
| FCC ID | 2AIHFZYCOV01 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AIHF |
| Product Code | ZYCOV01 |
| Applicant Business | Guilin Zhishen Information Technology Co.,Ltd. 🇨🇳 |
| Related Domains | |
| Equipment Class | TransMount Image Transmission Transmitter |
| Test Firm | Shenzhen Morlab Communications Technology Co. Ltd. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 5180-5240 MHz | Original Equipment | 2019-11-18 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2019-11-18 | PDF 1.8 MB |
| Internal Photos | Internal Photos | 2019-11-18 | PDF 1.7 MB |
| External Photos | External Photos | 2019-11-18 | PDF 1.7 MB |
| Label and label location | ID Label/Location Info | 2019-11-18 | PDF 88.7 KB |
| Annex B Test Setup Photos | Test Setup Photos | 2019-11-18 | PDF 559 KB |
| Test Setup Photos_NII | Test Setup Photos | 2019-11-18 | PDF 821.6 KB |
| Test report_wifi5G | Test Report | 2019-11-18 | PDF 3.7 MB |
| Confidentiality Request Letter | Cover Letter(s) | 2019-11-18 | PDF 268.3 KB |
| FCC Authorization Letter | Cover Letter(s) | 2019-11-18 | PDF 244.1 KB |
| FCC_DTS_UNII_Declaration | Cover Letter(s) | 2019-11-18 | PDF 73.9 KB |
| FCC_SDOC_letter | Cover Letter(s) | 2019-11-18 | PDF 199.3 KB |
| Annex A General Information | RF Exposure Info | 2019-11-18 | PDF 74 KB |
| Annex C Plots of System Performance Check | RF Exposure Info | 2019-11-18 | PDF 636.6 KB |
| Annex D Face Side_CH157_MIMO_open 45 deg | RF Exposure Info | 2019-11-18 | PDF 372.6 KB |
| Annex D Plots of Maximum SAR Test Results | RF Exposure Info | 2019-11-18 | PDF 1.1 MB |
| Annex E DASY Calibration Certificate - part 1 | RF Exposure Info | 2019-11-18 | PDF 3.5 MB |
| Annex E DASY Calibration Certificate - part 2 | RF Exposure Info | 2019-11-18 | PDF 4.8 MB |
| XM19100033W01_FCC | RF Exposure Info | 2019-11-18 | PDF 818.1 KB |
| Block Diagram Metadata only | Block Diagram | PDF 100.6 KB | |
| Schematics Metadata only | Schematics | PDF 268.9 KB | |
| OP Metadata only | Operational Description | PDF 280.6 KB | |
| OP_KDB Inquiry 946201 Metadata only | Operational Description | PDF 39.6 KB | |
| OP_KDB Inquiry 946204 Metadata only | Operational Description | PDF 39.6 KB | |
| operational_description Metadata only | Operational Description | PDF 307.5 KB | |
| Software Security Info Metadata only | SDR Software/Security Inf | PDF 1.3 MB | |
| BOM Metadata only | Parts List/Tune Up Info | PDF 102.1 KB | |
| Tune-up Metadata only | Parts List/Tune Up Info | PDF 98.3 KB |
Application Information
| Application ID | svCgAEVXE9WFJevn+NAVcg== |
|---|---|
| Final Action Date | 2019-11-18 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0025586488 |
| Model | ZYCOV01 |
| Frequency Range | 5180-5240 MHz |
| Equipment Class | NII - Unlicensed National Information Infrastructure TX |
| Device Description | TransMount Image Transmission Transmitter |
| Responsible Party | Yilun Liao, CEO, snow.Liao@zhiyun-tech.com |
| Test Firm | Mr. Su Feng, Shenzhen Morlab Communications Technology Co. Ltd., Zx.sun@morlab.cn |
| TCB Email | bentje.holger@phoenix-testlab.de |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | Yes |
| Grant Comments | Output power is maximum average conducted. This device supports 20 channel bandwidth. This device supports MIMO 2T2R. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0.5 cm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance The highest reported SAR values for body-worn accessory are 1.56 W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| svCgAEVXE9WFJevn+NAVcg== | 2019-11-18 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application svCgAEVXE9WFJevn+NAVcg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
PHOENIX TESTLAB GmbH Koenigswinkel 10 32825 Blomberg, Germany |
Date of Grant: 11/18/2019 Application Dated: 11/13/2019 |
| Guilin Zhishen Information Technology Co.,Ltd. |
| 09 Huangtong Road, Tieshan Industrial Zone, |
| QiXing District, |
| Guilin, Guangxi,, 541004 China |
| Attention: Yilun Liao , CEO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AIHFZYCOV01 |
| Name of Grantee: | Guilin Zhishen Information Technology Co.,Ltd. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | TransMount Image Transmission Transmitter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 15E | 5180.0 - 5240.0 | 0.107 | ||
| MO | 15E | 5745.0 - 5825.0 | 0.114 |
| Output power is maximum average conducted. This device supports 20 channel bandwidth. This device supports MIMO 2T2R. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0.5 cm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance The highest reported SAR values for body-worn accessory are 1.56 W/kg. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application svCgAEVXE9WFJevn+NAVcg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Guilin Zhishen Information Technology Co.,Ltd. 09 Huangtong Road, Tieshan Industrial Zone, QiXing District, Guilin, Guangxi,, 541004 China |
Date of Grant: 11/18/2019 Application Dated: 11/13/2019 |
| Attention: Yilun Liao , CEO |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AIHFZYCOV01 |
| Name of Grantee: | Guilin Zhishen Information Technology Co.,Ltd. |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | TransMount Image Transmission Transmitter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| MO | 15E | 5180.0 - 5240.0 | 0.107 | ||
| MO | 15E | 5745.0 - 5825.0 | 0.114 |
| Output power is maximum average conducted. This device supports 20 channel bandwidth. This device supports MIMO 2T2R. SAR compliance for body-worn operating configurations is limited to the belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0.5 cm separation between the device and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance The highest reported SAR values for body-worn accessory are 1.56 W/kg. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |