FCC ID 2AQI5-CM492
AC1300 Dual-Band Wireless Adapter
by Ugreen Group Limited
Grantee Code: 2AQI5 Product Code: CM492
Latest application date: 2021-10-20
FCC ID Device Details
| FCC ID | 2AQI5-CM492 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | 2AQI5 |
| Product Code | CM492 |
| Applicant Business | Ugreen Group Limited 🇨🇳 |
| Related Domains | |
| Equipment Class | AC1300 Dual-Band Wireless Adapter |
| Test Firm | Shenzhen Anbotek Compliance Laboratory Limited |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 2412-2462 MHz | Original Equipment | 2021-10-20 |
| 5180-5240 MHz | Original Equipment | 2021-10-20 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2021-10-20 | PDF 1.7 MB |
| Internal Photos | Internal Photos | 2021-10-20 | PDF 1.3 MB |
| Internal photos | Internal Photos | 2021-10-20 | PDF 1.3 MB |
| External Photos | External Photos | 2021-10-20 | PDF 790.9 KB |
| External photos | External Photos | 2021-10-20 | PDF 790.9 KB |
| Label | ID Label/Location Info | 2021-10-20 | PDF 117.7 KB |
| Label Location | ID Label/Location Info | 2021-10-20 | PDF 117.7 KB |
| Test Setup Photos | Test Setup Photos | 2021-10-20 | PDF 545.8 KB |
| SAR Test Report | RF Exposure Info | 2021-10-20 | PDF 5.7 MB |
| Test Report | Test Report | 2021-10-20 | PDF 4.6 MB |
| Test Report | Test Report | 2021-10-20 | PDF 3.5 MB |
| Declaration on Model Differences | Cover Letter(s) | 2021-10-20 | PDF 53.2 KB |
| FCC Agent Authorization Letter | Cover Letter(s) | 2021-10-20 | PDF 60.6 KB |
| FCC Short & Long Term Confidentiality Request Rev4.1 | Cover Letter(s) | 2021-10-20 | PDF 54.4 KB |
| FCC Software Configuration Control Declaration Rev1.1 | Cover Letter(s) | 2021-10-20 | PDF 80.5 KB |
| Block Diagram Metadata only | Block Diagram | PDF 110.6 KB | |
| SCH Metadata only | Schematics | PDF 5 MB | |
| OP Metadata only | Operational Description | PDF 82 KB | |
| Operation Description Metadata only | Operational Description | PDF 82 KB | |
| FCC SW SECURITY DESCRIPTION Metadata only | SDR Software/Security Inf | PDF 138.5 KB |
Application Information
| Application ID | UoOzDrSPzzoU93kS7Y9BDw== |
|---|---|
| Final Action Date | 2021-10-20 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0026099358 |
| Model | CM492 |
| Frequency Range | 2412-2462 MHz |
| Equipment Class | DTS - Digital Transmission System |
| Device Description | AC1300 Dual-Band Wireless Adapter |
| Responsible Party | Chi Yang, Manager, certification@ugreen.com |
| Technical Contact | Ugreen Group Limited, certification@ugreen.com |
| Test Firm | Jeff Zhu, Shenzhen Anbotek Compliance Laboratory Limited, jeff.zhu@anbotek.com |
| TCB Email | certification@micomlabs.com |
| TCB Scope | A4: UNII devices & low power transmitters using spread spectrum techniques |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | Yes |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory use conditions is 0.72W/kg. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| UoOzDrSPzzoU93kS7Y9BDw== | 2021-10-20 | Original Equipment |
| Jd+MjcyhV8E5/A7xXmAoyg== | 2021-10-20 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application UoOzDrSPzzoU93kS7Y9BDw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 10/20/2021 Application Dated: 10/20/2021 |
| Ugreen Group Limited |
| UGREEN Building,Longcheng Industrial Park |
| Longguanxi Road,Longhua |
| ShenZhen, 518000 China |
| Attention: Chi Yang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AQI5-CM492 |
| Name of Grantee: | Ugreen Group Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | AC1300 Dual-Band Wireless Adapter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.1112 |
| Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory use conditions is 0.72W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application UoOzDrSPzzoU93kS7Y9BDw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ugreen Group Limited UGREEN Building,Longcheng Industrial Park Longguanxi Road,Longhua ShenZhen, 518000 China |
Date of Grant: 10/20/2021 Application Dated: 10/20/2021 |
| Attention: Chi Yang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AQI5-CM492 |
| Name of Grantee: | Ugreen Group Limited |
| Equipment Class: | Digital Transmission System |
| Notes: | AC1300 Dual-Band Wireless Adapter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| CC MO | 15C | 2412.0 - 2462.0 | 0.1112 |
| Output power listed is maximum combined conducted power. This device contains 20 and 40 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory use conditions is 0.72W/kg. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
MiCOM Labs 575 Boulder Court Pleasanton, CA 94566 |
Date of Grant: 10/20/2021 Application Dated: 10/20/2021 |
| Ugreen Group Limited |
| UGREEN Building,Longcheng Industrial Park |
| Longguanxi Road,Longhua |
| ShenZhen, 518000 China |
| Attention: Chi Yang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AQI5-CM492 |
| Name of Grantee: | Ugreen Group Limited |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | AC1300 Dual-Band Wireless Adapter |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC MO | 15E | 5180.0 - 5240.0 | 0.0509 |
| Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory use conditions is 0.69W/kg. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
EAS Grant - Application Jd+MjcyhV8E5/A7xXmAoyg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ugreen Group Limited UGREEN Building,Longcheng Industrial Park Longguanxi Road,Longhua ShenZhen, 518000 China |
Date of Grant: 10/20/2021 Application Dated: 10/20/2021 |
| Attention: Chi Yang , Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | 2AQI5-CM492 |
| Name of Grantee: | Ugreen Group Limited |
| Equipment Class: | Unlicensed National Information Infrastructure TX |
| Notes: | AC1300 Dual-Band Wireless Adapter |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 38 CC MO | 15E | 5180.0 - 5240.0 | 0.0509 |
| Output power listed is maximum combined conducted power. This device contains 20, 40 and 80 MHz signal bandwidth. Device is a 2x2 MIMO as is described in the filing. SAR compliance for body-worn operating configurations is limited to the specific configurations tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 0 mm separation between the device and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR for body-worn accessory use conditions is 0.69W/kg. |
| 38: | This device has shown compliance, in all grant-listed U-NII sub-bands, with the new rules for U-NII devices adopted under Docket No. 13-49 and may be marketed, manufactured or imported after the June 1, 2016 transition deadline. |
| CC: | This device is certified pursuant to two different Part 15 rules sections. |
| MO: | This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing. |
| Mail To: |