FCC ID A3LSGHE608

Single-Band PCS GSM Phone

by Samsung Electronics Co Ltd

Grantee Code: A3L   Product Code: SGHE608
Latest application date: 2004-04-07

FCC ID Device Details

FCC IDA3LSGHE608
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeA3L
Product CodeSGHE608
Applicant BusinessSamsung Electronics Co Ltd 🇺🇸
Related Domains samsung.com
Equipment ClassSingle-Band PCS GSM Phone
Test FirmSAMSUNG ELECTRONICS CO., LTD.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
1850.2-1909.8 MHzOriginal Equipment2004-04-07

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2004-04-07PDF 3.8 MB
Internal PhotosInternal Photos2004-04-07PDF 81.1 KB
External PhotosExternal Photos2004-04-07PDF 119.2 KB
FCC ID Label and LocationID Label/Location Info2004-04-07PDF 702.1 KB
SAR Test Setup PhotosRF Exposure Info2004-04-07PDF 297.8 KB
Test Setup PhotosTest Setup Photos2004-04-07PDF 170.9 KB
Test ReportTest Report2004-04-07PDF 594 KB
Attestation StatementsAttestation Statements2004-04-07PDF 66.6 KB
Dipole ValidationRF Exposure Info2004-04-07PDF 1.9 MB
Probe CalibrationRF Exposure Info2004-04-07PDF 120.6 KB
SAR PlotsRF Exposure Info2004-04-07PDF 3 MB
SAR ReportRF Exposure Info2004-04-07PDF 2.3 MB
Block Diagram Metadata onlyBlock DiagramPDF 28.2 KB
Schematics Metadata onlySchematicsPDF 187.5 KB
Operational Description Metadata onlyOperational DescriptionPDF 91.8 KB
Parts List and Tune Up Procedure Metadata onlyParts List/Tune Up InfoPDF 85.8 KB

Application Information

Application IDlyCAorR3J8+7Z4wmaX3x3g==
Final Action Date2004-04-07
Application PurposeOriginal Equipment
Applicant FRN0027908797
ModelSGHE608
Frequency Range1850.2-1909.8 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionSingle-Band PCS GSM Phone
Responsible PartyJenni Chun, General Manager, j1.chun@samsung.com , 973-808-6375
AgentRandy Randy Randy, PCTEST Engineering Lab., Inc., randy@pctestlab.com , 410-290-6652
Technical ContactRandy Ortanez, PCTEST Engineering Lab., Inc., randy@pctestlab.com , 410-290-6652
Test FirmNo Cheon Park, SAMSUNG ELECTRONICS CO., LTD., ncpark@samsung.co..kr, 82-31-200-2185
TCB Emailrandy@pctestlab.com
TCB ScopeB1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput is EIRP. SAR compliance for body-worn operating configuration is based on a separation distance of 1.5 cm between the back of the phone and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metallic components. The highest reported SAR values are – Head: 0.550 W/kg: Body-worn: 0.358 W/kg. This device contains 900 MHz GSM and 1800 DCS functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations.

Applications

Application IDDatePurpose
lyCAorR3J8+7Z4wmaX3x3g==2004-04-07Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
1850.2-1909.8 MHz1.54500002.5000000000ppm300KGXW24E

Grants

TCB Grant - Application lyCAorR3J8+7Z4wmaX3x3g==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  PCTEST Engineering Laboratory, LLC
7185 Oakland Mills Road
Columbia, MD 21046
Date of Grant: 04/07/2004

Application Dated: 04/07/2004
Samsung Electronics Co Ltd
19 Chapin Rd., Building D
Pine Brook, NJ 07058
 
Attention: Jenni Chun , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  A3LSGHE608
Name of Grantee:  Samsung Electronics Co Ltd
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Single-Band PCS GSM Phone
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 1.545 2.5  PM 300KGXW

Output is EIRP. SAR compliance for body-worn operating configuration is based on a separation distance of 1.5 cm between the back of the phone and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metallic components. The highest reported SAR values are – Head: 0.550 W/kg: Body-worn: 0.358 W/kg.

This device contains 900 MHz GSM and 1800 DCS functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations.


EAS Grant - Application lyCAorR3J8+7Z4wmaX3x3g==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Samsung Electronics Co Ltd
19 Chapin Rd., Building D
Pine Brook, NJ 07058
United States
  Date of Grant: 04/07/2004

Application Dated: 04/07/2004
 
Attention: Jenni Chun , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  A3LSGHE608
Name of Grantee:  Samsung Electronics Co Ltd
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Single-Band PCS GSM Phone
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
24E 1850.2  -  1909.8 1.545 2.5  PM 300KGXW

Output is EIRP. SAR compliance for body-worn operating configuration is based on a separation distance of 1.5 cm between the back of the phone and the body of the user. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. Belt clips or holsters may not contain metallic components. The highest reported SAR values are – Head: 0.550 W/kg: Body-worn: 0.358 W/kg.

This device contains 900 MHz GSM and 1800 DCS functions that are not operational in U.S. Territories. This filing is only applicable for 1900 MHz PCS operations.