SMF907N Portable Handset Test Report Wireless Charging Samsung Electronics

Samsung Electronics Portable Handset

Alternate Views: PDF [Zoom] Download [PDF]

                                        PCTEST ENGINEERING LABORATORY, INC.
                                                        7185 Oakland Mills Road, Columbia, MD 21046 USA
                                                              Tel. 410.290.6652 / Fax 410.290.6654
                                                                      http://www.pctest.com

                                                               MEASUREMENT REPORT
                                                                                 FCC PART 15C

  Applicant Name:                                                                                Date of Testing:
  Samsung Electronics Co., Ltd.                                                                  01/22- 04/05/2019
  129, Samsung-ro,                                                                               Test Site/Location:
  Yeongtong-gu, Suwon-si                                                                         PCTEST Lab. Columbia, MD, USA
  Gyeonggi-do, 16677, Korea                                                                      Test Report Serial No.:
                                                                                                 1M1902200029-16.A3L


   FCC ID:                                                           A3LSMF907N
  APPLICANT:                                                         Samsung Electronics Co., Ltd.


  Application Type:                                                  Certification
  Model:                                                             SM-F907N
  EUT Type:                                                          Portable Handset
  Frequency Range:                                                   110 – 148kHz
  FCC Classification:                                                Part 15 Low Power Transmitter Below 1705kHz (DCD)
  FCC Rule Part(s):                                                  Part 15 Subpart C
  Test Procedure(s):                                                 ANSI C63.10-2013



  This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement report
  and was tested in accordance with the measurement procedures specified in ANSI C63.10-2013. Test results reported herein relate only to
  the item(s) tested.

  I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are
  correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the
  qualifications of all persons taking them.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 1 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                               T A B L E                       O F             C O N T E N T S

        1.0         Introduction ...................................................................................................................................... 3
                    1.1      Scope..................................................................................................................................................... 3
                    1.2      PCTEST Test Location .......................................................................................................................... 3
                    1.3      Test Facility / Accreditations .................................................................................................................. 3
        2.0         PRODUCT INFORMATION ............................................................................................................. 4
                    2.1      Equipment Description ........................................................................................................................... 4
                    2.2      Device Capabilities ................................................................................................................................ 4
                    2.3      Test Configuration ................................................................................................................................. 4
                    2.4      EMI Suppression Device(s)/Modifications.............................................................................................. 4
        3.0         DESCRIPTION OF TEST ................................................................................................................ 5
                    3.1      Evaluation Procedure ............................................................................................................................ 5
                    3.2      AC Line Conducted Emissions .............................................................................................................. 5
                    3.3      Radiated Emissions ............................................................................................................................... 6
                    3.4      Environmental Conditions ...................................................................................................................... 6
        4.0         ANTENNA REQUIREMENTS .......................................................................................................... 7
        5.0         MEASUREMENT UNCERTAINTY .................................................................................................. 8
        6.0         TEST EQUIPMENT CALIBRATION DATA ...................................................................................... 9
        7.0         TEST DATA ................................................................................................................................... 10
                    7.1      Summary ............................................................................................................................................. 10
                    7.2      Radiated Spurious Emission Measurements, Out-of-Band .................................................................. 11
                    7.3      Line Conducted Measurement Data .................................................................................................... 16
        8.0         CONCLUSION ............................................................................................................................... 19




                                                                               MEASUREMENT REPORT                                                                 Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                                 Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                  Page 2 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


1.0              INTRODUCTION

1.1           Scope
Measurement and determination of electromagnetic emissions (EMC) of radio frequency devices including
intentional and/or unintentional radiators for compliance with the technical rules and regulations of the Federal
Communications Commission and the Innovation, Science and Economic Development Canada.

1.2           PCTEST Test Location
These measurement tests were conducted at the PCTEST Engineering Laboratory, Inc. facility located at 7185
Oakland Mills Road, Columbia, MD 21046. The measurement facility is compliant with the test site requirements
specified in ANSI C63.4-2014.

1.3           Test Facility / Accreditations
Measurements were performed at PCTEST Engineering Lab located in Columbia, MD 21046, U.S.A.

•     PCTEST is an ISO 17025-2005 accredited test facility under the American Association for Laboratory
      Accreditation (A2LA) with Certificate number 2041.01 for Specific Absorption Rate (SAR), Hearing Aid
      Compatibility (HAC) testing, where applicable, and Electromagnetic Compatibility (EMC) testing for FCC and
      Innovation, Science, and Economic Development Canada rules.

•     PCTEST TCB is a Telecommunication Certification Body (TCB) accredited to ISO/IEC 17065-2012 by A2LA
      (Certificate number 2041.03) in all scopes of FCC Rules and ISED Standards (RSS).

•     PCTEST facility is a registered (2451B) test laboratory with the site description on file with ISED.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 3 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


2.0              PRODUCT INFORMATION


2.1           Equipment Description
The Equipment Under Test (EUT) is the Samsung Portable Handset FCC ID: A3LSMF907N. The test data
contained in this report pertains only to the emissions generated by the IC of the EUT that receive or transmit AC
power signal through magnetic induction (MI) or magnetic resonance (MR) wirelessly.

Test Device Serial No.: 0001M, 0039M, 0041M

2.2           Device Capabilities
This device contains the following capabilities:

850/1900 GSM/GPRS/EDGE, 850/1700/1900 WCDMA, 802.11b/g/n/ax WLAN, 802.11a/n/ac/ax UNII, Bluetooth
(1x, EDR, LE), NFC, ANT+, Wireless Power Transfer

2.3           Test Configuration
The EUT can be configured to receive or transmit an AC power signal through magnetic induction (MI) or
magnetic resonance (MR). The operating frequency range is 110 – 148kHz and can produce a maximum power
of 9W.

During testing, one of the devices is configured to be AC power transmitter, and the other is configured to be
receiver. The charging area of both devices are aligned to provide for maximum power transfer. The EUT was
tested in accordance with the guidance of ANSI C63.10-2013. See Sections 3.2 and 3.3 of this test report for a
description of the AC line conducted and radiated emissions test setups, respectively.

The EUT is capable of being folded closed and unfolded open while being fully operational in both configurations.

2.4           EMI Suppression Device(s)/Modifications
No EMI suppression device(s) were added and no modifications were made during testing.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 4 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


3.0              DESCRIPTION OF TEST

3.1           Evaluation Procedure
The measurement procedure described in the American National Standard of Procedures for Compliance Testing
of Unlicensed Wireless Devices (ANSI C63.10-2013) was used in the measurement of the EUT.

Deviation from measurement procedure…………………………………………….....................................None

3.2           AC Line Conducted Emissions
The line-conducted facility is located inside a 10'x16'x9' shielded enclosure. The shielded enclosure is
manufactured by ETS Lindgren RF Enclosures. The shielding effectiveness of the shielded room is in accordance
with MIL-Std-285 or NSA 65-5. A 1m x 1.5m wooden table 80cm high is placed 40cm away from the vertical wall
and 80cm away from the sidewall of the shielded room. Two 10kHz-30MHz, 50Ω/50µH Line-Impedance
Stabilization Networks (LISNs) are bonded to the shielded room floor. Power to the LISNs is filtered by external
high-current high-insertion loss power line filters. The external power line filter is an ETS Lindgren Model LPRX-
4X30 (100dB Attenuation, 14kHz-18GHz) and the two EMI/RFI filters are ETS Lindgren Model LRW-2030-S1
(100dB Minimum Insertion Loss, 14kHz – 10GHz). These filters attenuate ambient signal noise from entering the
measurement lines. These filters are also bonded to the shielded enclosure.

The EUT is powered from one LISN and the support equipment is powered from the second LISN. If the EUT is a
DC-powered device, power will be derived from the source power supply it normally will be powered from and this
supply line(s) will be connected to the second LISN. All interconnecting cables more than 1 meter were shortened
to a 1 meter length by non-inductive bundling (serpentine fashion) and draped over the back edge of the test
table. All cables were at least 40cm above the horizontal reference groundplane. Power cables for support
equipment were routed down to the second LISN while ensuring that that cables were not draped over the second
LISN.

Sufficient time for the EUT, support equipment, and test equipment was allowed in order for them to warm up to
their normal operating condition. The RF output of the LISN was connected to the spectrum analyzer and
exploratory measurements were made to determine the frequencies producing the maximum emission from the
EUT. The spectrum was scanned from 150kHz to 30MHz with a spectrum analyzer. The detector function was set
to peak mode for exploratory measurements while the bandwidth of the analyzer was set to 10kHz. The EUT,
support equipment, and interconnecting cables were arranged and manipulated to maximize each emission. Once
the worst case emissions have been identified, the one EUT cable configuration/arrangement and mode of
operation that produced these emissions is used for final measurements on the same test site. The analyzer is set
to CISPR quasi-peak and average detectors with a 9kHz resolution bandwidth for final measurements.

Line conducted emissions test results are shown in Section 7.3. Automated test software was used to perform the
AC line conducted emissions testing.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 5 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


3.3           Radiated Emissions
The radiated test facilities consisted of an indoor 3 meter semi-anechoic chamber used for final measurements
and exploratory measurements, when necessary. The measurement area is contained within the semi-anechoic
chamber which is shielded from any ambient interference. The test site inside the chamber is a 6m x 5.2m
elliptical, obstruction-free area in accordance with Figure 5.7 of Clause 5 in ANSI C63.4-2014. Absorbers are
arranged on the floor between the turn table and the antenna mast in such a way so as to maximize the reduction
of reflections for measurements above 1GHz. An 80cm tall test table made of Styrodur is placed on top of the turn
table. For measurements above 1GHz, an additional Styrodur pedestal is placed on top of the test table to bring
the total table height to 1.5m.

For all measurements, the spectrum was scanned through all EUT azimuths and from 1 to 4 meter receive
antenna height using a broadband antenna from 30MHz up to the upper frequency shown in 15.33 depending on
the highest frequency generated or used in the device or on which the device operates or tunes. For frequencies
above 1GHz, linearly polarized double ridge horn antennas were used. For frequencies below 30MHz, a
calibrated loop antenna was used. When exploratory measurements were necessary, they were performed at 1
meter test distance inside the semi-anechoic chamber using broadband antennas, broadband amplifiers, and
spectrum analyzers to determine the frequencies and modes producing the maximum emissions. Sufficient time
for the EUT, support equipment, and test equipment was allowed in order for them to warm up to their normal
operating condition. The test set-up was placed on top of the 1 x 1.5 meter table. The EUT, support equipment,
and interconnecting cables were arranged and manipulated to maximize each emission. Appropriate precaution
was taken to ensure that all emissions from the EUT were maximized and investigated. The system configuration,
mode of operation, turntable azimuth, and receive antenna height was noted for each frequency found.

Final measurements were made in the semi-anechoic chamber using calibrated, linearly polarized broadband and
horn antennas. The test setup was configured to the setup that produced the worst case emissions. The spectrum
analyzer was set to investigate all frequencies required for testing to compare the highest radiated disturbances
with respect to the specified limits. The turntable containing the EUT was rotated through 360 degrees and the
height of the receive antenna was varied 1 to 4 meters and stopped at the azimuth and height producing the
maximum emission. Each emission was maximized by changing the orientation of the EUT through three
orthogonal planes and changing the polarity of the receive antenna, whichever produced the worst-case
emissions.

3.4           Environmental Conditions
The temperature is controlled within range of 15oC to 35oC. The relative humidity is controlled within range of 10%
to 75%. The atmospheric pressure is monitored within the range 86-106kPa (860-1060mbar).




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 6 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


4.0           ANTENNA REQUIREMENTS

 Excerpt from §15.203 of the FCC Rules/Regulations:
 “An intentional radiator antenna shall be designed to ensure that no antenna other than that furnished by the
 responsible party can be used with the device. The use of a permanently attached antenna or of an antenna that
 uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of
 this section.”


      •   The antenna of the EUT are permanently attached.

      •   This unit was tested with its standard battery.


 Conclusion:
 The EUT complies with the requirement of §15.203.




                                                                                MEASUREMENT REPORT                                                               Approved by:
  FCC ID: A3LSMF907N
                                                                                   (CERTIFICATION)                                                               Quality Manager
  Test Report S/N:                 Test Dates:                       EUT Type:
                                                                                                                                                                 Page 7 of 19
  1M1902200029-16.A3L              01/22- 04/05/2019                Portable Handset
 © 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
 All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
 microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
 rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


5.0              MEASUREMENT UNCERTAINTY

The measurement uncertainties shown below were calculated in accordance with the requirements of
ANSI C63.10-2013. All measurement uncertainty values are shown with a coverage factor of k = 2 to indicate a
95% level of confidence. The measurement uncertainty shown below meets or exceeds the UCISPR measurement
uncertainty values specified in CISPR 16-4-2 and, thus, can be compared directly to specified limits to determine
compliance.


                                                  Contribution                                        Expanded Uncertainty (±dB)

                                      Line Conducted Disturbance                                                            3.09

                                    Radiated Disturbance (<1GHz)                                                            4.98




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 8 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


  6.0              TEST EQUIPMENT CALIBRATION DATA

Test Equipment Calibration is traceable to the National Institute of Standards and Technology (NIST).
Measurements antennas used during testing were calibrated in accordance to the requirements of ANSI C63.5-
2017.

   Manufacturer                    Model                                    Description                              Cal Date        Cal Interval        Cal Due        Serial Number

     Com-Power                     AL-130                         9kHz - 30MHz Loop Antenna                         10/10/2017          Biennial       10/10/2019             121034

     Com-Power                   PAM-103                           Pre-Amplifier (1-1000MHz)                         9/17/2018           Annual         9/17/2019             441119

    ETS-Lindgren                3816/2NM                    Line Impedance Stabilization Network                     6/18/2018          Biennial        6/18/2020             114451

      Pasternack                  NMLC-2                    Line Conducted Emissions Cable (NM)                      8/23/2018           Annual         8/23/2019            NMLC-2

 Rohde & Schwarz                   ESU26                          EMI Test Receiver (26.5GHz)                        5/21/2018           Annual         5/21/2019             100342

 Rohde & Schwarz                SFUNIT-Rx                               Shielded Filter Unit                         6/18/2018           Annual         6/18/2019             102134

         Sunol                   DRH-118                            Horn Antenna (1-18 GHz)                          8/11/2017          Biennial        8/11/2019           A042511

         Sunol                       JB5                          Bi-Log Antenna (30M - 5GHz)                        4/19/2018          Biennial        4/19/2020           A051107
                                             Table 6-1. Annual Test Equipment Calibration Schedule




                                                                                 MEASUREMENT REPORT                                                               Approved by:
  FCC ID: A3LSMF907N
                                                                                    (CERTIFICATION)                                                               Quality Manager
  Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                  Page 9 of 19
  1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
  © 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
  All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
  microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
  rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.0              TEST DATA

7.1           Summary


          Company Name:                                   Samsung Electronics Co., Ltd.
          FCC ID:                                         A3LSMF907N
          FCC Classification:                             Part 15 Low Power Transmitter Below 1705kHz (DCD)
          Frequency Range:                                110 – 148kHz

    FCC Part                                                                                                                          Test                 Test
                         RSS Section(s)                  Test Description                            Test Limit                                                           Reference
    Section(s)                                                                                                                      Condition             Result


                                                                                            Emissions must meet the
                         RSS-Gen [8.9]              Out-of-Band Emissions                   radiated limits detailed in               Radiated              PASS            Section 7.2
 15.209
                                                                                            15.209 (RSS-Gen [8.9])



                                                    AC Conducted Emissions                  < FCC 15.207 limits                      LINE
 15.207                  RSS-Gen [8.8]                                                                                                                      PASS            Section 7.3
                                                    150kHz – 30MHz                          (RSS-Gen)                             CONDUCTED

                                                               Table 7-1. Summary of Test Results

Note:

This unit was tested while transferring maximum power wirelessly to a similar unit.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 10 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.2           Radiated Spurious Emission Measurements, Out-of-Band
§15.209; RSS-Gen (8.9)

Test Overview and Limit

The EUT was tested from 9kHz up to the 30MHz. All measurements up to 30MHz were recorded with a spectrum
analyzer employing a quasi-peak detector.

 All out-of-band emissions must not exceed the limits shown in Table 7-2 per Section 15.209.

                                                                                  Field Strength                           Measured Distance
                                        Frequency
                                                                                      [µV/m]                                   [Meters]
                                   0.009 – 0.490 MHz                                 2400/F (kHz)                                        300
                                   0.490 – 1.705 MHz                                24000/F (kHz)                                         30
                                   1.705 – 30.00 MHz                                         30                                           30
                                   30.00 – 88.00 MHz                                        100                                            3
                                   88.00 – 216.0 MHz                                        150                                            3
                                   216.0 – 960.0 MHz                                        200                                            3
                                    Above 960.0 MHz                                         500                                            3
                                                           Table 7-2. Radiated Limits – Out of band

Test Procedures Used

ANSI C63.10-2013 – Section 6.5.4

Test Settings

             1. Analyzer center frequency was set to the frequency of the radiated spurious emission of interest
             2. RBW = 9kHz for emissions below 30MHz
             3. VBW ≥ 3 x RBW
             4. Detector = peak
             5. Sweep time = auto couple
             6. Trace mode = max hold
             7. Trace was allowed to stabilize




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 11 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


&     PCTEST

Test Setup
The EUT and measurement equipment were set up as shown in the diagram below.




                                                                                                                                                       Im to 4m




                                                    EUT
                         {




                           0.8m                       turntable                                                                 entenna mast
                         ’,




                                                                                                                            |
                                            [                                    im                                         1
                                                                  Figure 7—1. Radiated Test Setup


Test Notes:

       1.    All measurements were recorded using a spectrum analyzer employing a quasi—peak detector for
             emissions below 3OMHz.
             A loop antenna was used to investigate emissions below 3OMHz.
             Below 30MHz the loop antenna was positioned in 3 orthogonal planes (X front, Y side, Z top) to
             determine the orientation resulting in the worst case emissions.
      4.     The EUT was positioned in three orthogonal planes to determine the orientation resulting in the worst
             case emissions.
             The spectrum is investigated from 9kHz up to 30MHz per §15.33. The worst—case emissions are reported.
             No spurious emissions levels were found to be greater than the level of the fundamental.
             The "—" shown in the following RSE tables are used to denote a noise floor measurement.

Sample Calculation

o      Field Strength Level ewin = Analyzer Level pam) + 107 + AFCL fasin]
o      AFCL pei= Antenna Factor pem) + Cable Loss jas;

o      Margin s = Field Strength Level sn — Limit aBavin]




FCC ID: A8LSMFOO7N                  «AAELm+—                                  MEASUREMENT REPORT                                                              Approved by:
                                                                                   (CERTIFICATION)                                    @                       Quality Manager
Test Report S/N:                  Test Dates:                      EUT Type:
                                                                                                                                                              Page
1M1902200029—16.48L.              o1/22: 40572019                  Portable Handset                                                                                  age 12 120 0f 19
©2019 PGTEST Engnesning Laboralory, Inc.                                                                                                                                    v ao o2ov201e
All rights reserved. Unless olternise specified, no part of this report may be reproduced or utlized in any par, form or by any means, electronic or mechanical, including photocopying and
microfim, without permission in wriing from PGTEST Engineering Laboratory, Inc. If you have any questions about this internalional copyright or have an enguiry about oblaining adtional
rights to this report or assembly of contents thereot, please contact INFO@PCTEST.COM.


Radiated Spurious Emission Measurements, Out-of-Band
§15.209; RSS-Gen (8.9)




                                        Plot 7-1. Radiated Spurious Plot 9kHz – 30MHz (Pol. X - WPT)




                                         Plot 7-2Radiated Spurious Plot 9kHz – 30MHz (Pol. Y - WPT)




                                        Plot 7-3. Radiated Spurious Plot 9kHz – 30MHz (Pol. Z - WPT)
                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 13 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                           Plot 7-4. Radiated Spurious Plot 9kHz – 30MHz (Pol. X – WPT with Earbuds)




                           Plot 7-5. Radiated Spurious Plot 9kHz – 30MHz (Pol. Y – WPT with Earbuds)




                           Plot 7-6. Radiated Spurious Plot 9kHz – 30MHz (Pol. Z – WPT with Earbuds)

                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 14 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Radiated Spurious Emission Measurements, Out-of-Band
§15.209; RSS-Gen (8.9)


  Tx Frequency                                         148kHz

  Measurement Distance:                                3 Meters


                                        Antenna Turntable                                                3m Field 300m Field
 Frequency            Ant. Pol.                                            Level            AFCL                                                 Limit          Limit  Margin
                                         Height  Azimuth                                                 Strength Strength
   [MHz]               [X/Y/Z]                                             [dBm]           [dB/m]                                               [µV/m]        [dBµV/m]  [dB]
                                          [cm]  [degree]                                                 [dBµV/m] [dBµV/m]

      0.148                 X               100                -            -56.17          29.86           80.69              0.69              16.26           24.22           -23.54

      0.295                 X               100                -            -62.59          29.74           74.15              -5.85              8.13           18.20           -24.05

      0.443                 X               100                -            -66.08          29.85           70.77              -9.23              5.42           14.68           -23.91

      0.590                 X               100                -            -67.92          29.97           69.05             -10.95             40.65           32.18           -43.13

      0.738                 X               100                -            -70.96          29.98           66.02             -13.98             32.52           30.24           -44.23

      0.886                 X               100                -            -73.19          30.07           63.88             -16.12             27.10           28.66           -44.78

      1.033                 X               100                -            -74.33          30.30           62.97             -17.03             23.23           27.32           -44.35

      0.148                 X               100                -            -56.33          29.86           80.53              0.53              16.26           24.22           -23.70

                                                                     Table 7-3. Radiated Measurements


                                        Antenna Turntable                                                3m Field 300m Field
 Frequency            Ant. Pol.                                            Level            AFCL                                                 Limit          Limit  Margin
                                         Height  Azimuth                                                  Strength Strength
   [MHz]               [X/Y/Z]                                             [dBm]           [dB/m]                                               [µV/m]        [dBµV/m]  [dB]
                                          [cm]   [degree]                                                [dBµV/m] [dBµV/m]

      0.148                 X               100                -            -56.62          29.86           80.24              0.24              16.26           24.22           -23.99

      0.295                 X               100                -            -62.84          29.74           73.90              -6.10              8.13           18.20           -24.30

      0.443                 X               100                -            -66.75          29.85           70.10              -9.90              5.42           14.68           -24.58

      0.590                 X               100                -            -67.89          29.97           69.08             -10.92             40.65           32.18           -43.10

      0.738                 X               100                -            -71.43          29.98           65.55             -14.45             32.52           30.24           -44.70

      0.886                 X               100                -            -72.90          30.07           64.17             -15.83             27.10           28.66           -44.49

      1.033                 X               100                -            -74.42          30.30           62.88             -17.12             23.23           27.32           -44.44

      0.148                 X               100                -            -56.91          29.86           79.95              -0.05             16.26           24.22           -24.28

                                                         Table 7-4. Radiated Measurements with Earbuds




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 15 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.3           Line Conducted Measurement Data
§15.207; RSS-Gen (8.8)

Test Overview and Limit

All AC line conducted spurious emissions are measured with a receiver connected to a grounded LISN while the
EUT is operating at its maximum duty cycle, at maximum power, and at the appropriate frequencies. All data rates
and modes were investigated for conducted spurious emissions. Only the conducted emissions of the
configuration that produced the worst case emissions are reported in this section.

All conducted emissions must not exceed the limits shown in the table below, per Section 15.207 and
RSS-Gen (8.8).


                            Frequency of emission                                               Conducted Limit (dBµV)
                                   (MHz)
                                                                                     Quasi-peak                                      Average
                                         0.15 – 0.5                                   66 to 56*                                      56 to 46*
                                           0.5 – 5                                       56                                             46
                                           5 – 30                                        60                                             50
                                                                     Table 7-5. Conducted Limits

*Decreases with the logarithm of the frequency.

Test Procedures Used

ANSI C63.10-2013, Section 6.2

Test Settings

             Quasi-Peak Field Strength Measurements

             1. Analyzer center frequency was set to the frequency of the spurious emission of interest
             2. RBW = 9kHz (for emissions from 150kHz – 30MHz)
             3. Detector = quasi-peak
             4. Sweep time = auto couple
             5. Trace mode = max hold
             6. Trace was allowed to stabilize
             Average Field Strength Measurements

             1. Analyzer center frequency was set to the frequency of the spurious emission of interest
             2. RBW = 9kHz (for emissions from 150kHz – 30MHz)
             3. Detector = RMS
             4. Sweep time = auto couple
             5. Trace mode = max hold
             6. Trace was allowed to stabilize



                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 16 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


       PCTEST

 Test Setup

 The EUT and measurement equipment were set up as shown in the diagram below.




                                                                                                                                travel
                                                                                                                                adapter
                                           1 mx 1.5 m                                                         10 om
                                           nonconducting platform



                                                                                                                                                    1m
                                                                                                                                                    exander cable


       80 om



                            LISN




                                                                     reference ground plane
                                               Figure 7—2. Test Instrument & Measurement Setup

 Test Notes

          All modes of operation were investigated and the worst—case emissions are reported using mid channel.
          The emissions found were not affected by the choice of channel used during testing.
          The limit for an intentional radiator from 150kHz to 30MHz are specified in 15.207 and RSS—Gen (8.8).
h




          Corr.(dB) = Cable loss (dB) + LISN insertion factor (dB)
s




          QP/AV Level (dBuV) = QP/AV Analyzer/Receiver Level (dBuV) + Corr. (dB)
&




          Margin (dB) = QP/AV Limit (dBpV) — QP/AV Level (dBuV)
o




          Traces shown in plot are made using a peak detector.
~O—p




          Deviations to the Specifications: None.




  ree ip: astsvreorN               BArRAL—                               measurement rerort                                                         Approved by:
                                                                            {certirication)                                W                        Qualty Manager
 Test Report SMN:                Test Dates:                   EUT Type:
  inc02z00000—te.Aat.__|         ovz— owrosizor9               Portable Handset                                                                     Page 17 of 19
 ©2015 FGTEST Engneemg Laboraan, me                                                                                                                             vancemcne
 Allrghts reservec. Unless otherniae spealfec, no prtofthsreport may be reprodveed o utlzed in any part, form or by any meants, lecfonicar mechanial Including photocapying and
 mirolim, wihout permiasionin wiirg rom PGTEST EngineeringLaboretory, no.!f you have any questons abolt titermalonal copyightorhave an enguiy about obaiing acltonal
 fls tothis reportr assembl of contents tereat, fease contect INFO®RCTEST. COM


                                                            Plot 7-7. Line-Conducted Test Plot (L1)




                                                             Plot 7-8. Line-Conducted Test Plot (N)


                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 18 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


8.0              CONCLUSION

The data collected relate only to the item(s) tested and show that the Samsung Portable Handset
FCC ID: A3LSMF907N has been verified to comply with the requirements specified in Part 15 (§15.207 and
§15.209) of the FCC Rules.




                                                                               MEASUREMENT REPORT                                                               Approved by:
FCC ID: A3LSMF907N
                                                                                  (CERTIFICATION)                                                               Quality Manager
Test Report S/N:                  Test Dates:                       EUT Type:
                                                                                                                                                                Page 19 of 19
1M1902200029-16.A3L               01/22- 04/05/2019                Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 9.0 02/01/2019
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.



Document Created: 2019-04-26 22:08:37
Document Modified: 2019-04-26 22:08:37
Download: SMF907N Portable Handset Test Report Wireless Charging Samsung Electronics
Mirror Download [FCC.gov]SMF907N Portable Handset Test Report Wireless Charging Samsung Electronics
Document ID4254852
Application ID2hOnnGTKHTFpesUdez+m1g==
Document DescriptionWireless Charging Test Report
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeTest Report
Display FormatAdobe Acrobat PDF - pdf
Filesize49.08kB (613449 bits)
Date Submitted2019-04-26 00:00:00
Date Available2019-04-26 00:00:00
Creation Date2019-04-25 19:39:14
Producing SoftwareAdobe PDF Library 19.10.131
Document Lastmod2019-04-26 09:31:48
Document TitleWireless Charging Test Report
Document CreatorAcrobat PDFMaker 19 for Word