FCC ID A6G-C4DGL3GV6
Telematics embedded system
by MUNIC
Grantee Code: A6G Product Code: C4DGL3GV6
Latest application date: 2016-12-22
FCC ID Device Details
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 824.2-848.8 MHz | Original Equipment | 2016-12-22 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User manual | Users Manual | 2017-06-20 | PDF 560.6 KB |
| Internal photos part 1 | Internal Photos | 2017-06-20 | PDF 4.9 MB |
| Internal photos part 2 | Internal Photos | 2017-06-20 | PDF 4.9 MB |
| Internal photos part 3 | Internal Photos | 2017-06-20 | PDF 3.2 MB |
| External photos | External Photos | 2017-06-20 | PDF 1.2 MB |
| Label | ID Label/Location Info | 2016-12-22 | PDF 1.2 MB |
| Label location | ID Label/Location Info | 2016-12-22 | PDF 27 KB |
| SAR test setup | Test Setup Photos | 2017-06-20 | PDF 119.1 KB |
| Test setup | Test Setup Photos | 2017-06-20 | PDF 130.6 KB |
| Test report | Test Report | 2016-12-22 | PDF 4.1 MB |
| Cover letter | Cover Letter(s) | 2016-12-22 | PDF 601.2 KB |
| SAR report part 1 | RF Exposure Info | 2016-12-22 | PDF 4.9 MB |
| SAR report part 2 | RF Exposure Info | 2016-12-22 | PDF 4.3 MB |
| Block Diagram Metadata only | Block Diagram | PDF 37.7 KB | |
| Schematics Metadata only | Schematics | PDF 261.5 KB | |
| Operational Description Metadata only | Operational Description | PDF 2.6 MB | |
| Parts list Metadata only | Parts List/Tune Up Info | PDF 97.9 KB | |
| Tune up Metadata only | Parts List/Tune Up Info | PDF 57.7 KB |
Application Information
| Application ID | zFlxFFVzUstfS7fYzBHaUQ== |
|---|---|
| Final Action Date | 2016-12-22 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0023537749 |
| Model | C4DGL3GV6 |
| Frequency Range | 824.2-848.8 MHz |
| Equipment Class | PCB - PCS Licensed Transmitter |
| Device Description | Telematics embedded system |
| Responsible Party | Meriem ZERAOUI, Certification Manager, meriem.zeraoui@munic.io |
| Test Firm | Michael Lin, SPORTON International(ShenZhen) Inc., michael@sporton.com.tw |
| TCB Email | stuart.beck@nemko.com |
| TCB Scope | B1: Commercial mobile radio services equipment in the following 47 CFR Parts 20, 22 (cellular), 24,25 (below 3 GHz) & 27 |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 06/20/2017 |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power output listed is ERP for Part 22 and EIRP for Part 24. Device must operate with the minimum separation distance of 1.5 cm between device and body for SAR compliance as described in this filing. The highest reported SAR for stand-alone exposure conditions is 1.46 W/kg. Users and installers must be informed of the operating requirements for satisfying RF exposure compliance. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| zFlxFFVzUstfS7fYzBHaUQ== | 2016-12-22 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application zFlxFFVzUstfS7fYzBHaUQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko North America, INC. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 12/22/2016 Application Dated: 12/22/2016 |
| MUNIC |
| 100 AVENUE DE STALINGRAD |
| VILLEJUIF, 94800 France |
| Attention: Meriem ZERAOUI , Certification Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | A6G-C4DGL3GV6 |
| Name of Grantee: | MUNIC |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Telematics embedded system |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 2.3408 | 0.0281 PM | 241KGXW | |
| 22H | 826.4 - 846.6 | 0.0868 | 0.0227 PM | 4M08F9W | |
| 24E | 1850.2 - 1909.8 | 1.9785 | 0.0101 PM | 244KGXW | |
| 24E | 1852.4 - 1907.6 | 0.1157 | 0.0133 PM | 4M09F9W |
| Power output listed is ERP for Part 22 and EIRP for Part 24. Device must operate with the minimum separation distance of 1.5 cm between device and body for SAR compliance as described in this filing. The highest reported SAR for stand-alone exposure conditions is 1.46 W/kg. Users and installers must be informed of the operating requirements for satisfying RF exposure compliance. |
EAS Grant - Application zFlxFFVzUstfS7fYzBHaUQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
MUNIC 100 AVENUE DE STALINGRAD VILLEJUIF, 94800 France |
Date of Grant: 12/22/2016 Application Dated: 12/22/2016 |
| Attention: Meriem ZERAOUI , Certification Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | A6G-C4DGL3GV6 |
| Name of Grantee: | MUNIC |
| Equipment Class: | PCS Licensed Transmitter |
| Notes: | Telematics embedded system |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 22H | 824.2 - 848.8 | 2.3408 | 0.0281 PM | 241KGXW | |
| 22H | 826.4 - 846.6 | 0.0868 | 0.0227 PM | 4M08F9W | |
| 24E | 1850.2 - 1909.8 | 1.9785 | 0.0101 PM | 244KGXW | |
| 24E | 1852.4 - 1907.6 | 0.1157 | 0.0133 PM | 4M09F9W |
| Power output listed is ERP for Part 22 and EIRP for Part 24. Device must operate with the minimum separation distance of 1.5 cm between device and body for SAR compliance as described in this filing. The highest reported SAR for stand-alone exposure conditions is 1.46 W/kg. Users and installers must be informed of the operating requirements for satisfying RF exposure compliance. |
| Mail To: |