FCC ID A8J-ECB350

11n Multi-Function Client Bridge

by EnGenius Technologies

Grantee Code: A8J   Product Code: ECB350
Latest application date: 2012-01-11

FCC ID Device Details

FCC IDA8J-ECB350
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeA8J
Product CodeECB350
Applicant BusinessEnGenius Technologies 🇺🇸
Related Domains engeniustech.com tw.bureauveritas.com
Equipment Class11n Multi-Function Client Bridge
Test FirmBureau Veritas CPS (H.K.) Ltd. Taoyuan Branch

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
2412-2462 MHzOriginal Equipment2012-01-11

Exhibits

DocumentTypeAvailableFile
User ManualUsers Manual2012-01-11PDF 3.6 MB
Internal PhotosInternal Photos2012-01-11PDF 244.5 KB
External PhotosExternal Photos2012-01-11PDF 137.1 KB
LabelID Label/Location Info2012-01-11PDF 289 KB
Label LocationID Label/Location Info2012-01-11PDF 72.5 KB
Operational DescriptionOperational Description2012-01-11PDF 8.7 KB
Test Setup PhotosTest Setup Photos2012-01-11PDF 155.8 KB
Test ReportTest Report2012-01-11PDF 697.4 KB
Attestation Statement Channel DeclarationAttestation Statements2012-01-11PDF 47 KB
Confidentiality RequestCover Letter(s)2012-01-11PDF 56.5 KB
Cover Letter Agent AuthorizationCover Letter(s)2012-01-11PDF 53.7 KB
RF Exposure InfoRF Exposure Info2012-01-11PDF 33.7 KB

Application Information

Application ID321TOwW5AtJNn3cGB+v4BQ==
Final Action Date2012-01-11
Application PurposeOriginal Equipment
Applicant FRN0021371836
Model-ECB350
Frequency Range2412-2462 MHz
Equipment ClassDTS - Digital Transmission System
Device Description11n Multi-Function Client Bridge
Responsible PartyAndy Chang, General Manager, andy.chang@engeniustech.com , 888.735.7888
Technical ContactGary Chang, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, gary.chang@tw.bureauveritas.com , 886-3-3183232
Non-Technical ContactNatacha Chen, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, natacha.chen@tw.bureauveritas.com , 886-3-3183232
Test FirmRichard Chen, Bureau Veritas CPS (H.K.) Ltd. Taoyuan Branch, richard.chen@tw.bureauveritas.com , 886-3-3183232
TCB Emailcertification@curtis-straus.com
TCB ScopeA4: UNII devices & low power transmitters using spread spectrum techniques
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsPower listed is the maximum combined conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

Applications

Application IDDatePurpose
321TOwW5AtJNn3cGB+v4BQ==2012-01-11Original Equipment

Equipment Authorization

FrequencyOutputRulesGrant Notes
2412-2462 MHz0.527000015CMO

Grants

TCB Grant - Application 321TOwW5AtJNn3cGB+v4BQ==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Curtis-Straus LLC
One Distribution Center Circle Suite #1
Littleton, MA 01460
Date of Grant: 01/11/2012

Application Dated: 01/11/2012
EnGenius Technologies
1580 Scenic Avenue,
Costa Mesa, CA 92626
 
Attention: Andy Chang , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  A8J-ECB350
Name of Grantee:  EnGenius Technologies
Equipment Class: Digital Transmission System
Notes: 11n Multi-Function Client Bridge
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15C 2412.0  -  2462.0 0.527  

Power listed is the maximum combined conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

EAS Grant - Application 321TOwW5AtJNn3cGB+v4BQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

EnGenius Technologies
1580 Scenic Avenue, P.O. Box ,
Costa Mesa, CA 92626
United States
  Date of Grant: 01/11/2012

Application Dated: 01/11/2012
 
Attention: Andy Chang , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  A8J-ECB350
Name of Grantee:  EnGenius Technologies
Equipment Class: Digital Transmission System
Notes: 11n Multi-Function Client Bridge
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
MO 15C 2412.0  -  2462.0 0.527  

Power listed is the maximum combined conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.


MO: This Multiple Input Multiple Output (MIMO) device was evaluated for multiple transmitted signals as indicated in the filing.

Mail To: