Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 1921.536-1928.448 MHz | Class II permissive change or modification of presently authorized equipment | 2009-12-15 |
| 1921.536-1928.448 MHz | Original Equipment | 2008-12-22 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual | Users Manual | 2009-02-05 | PDF 1.9 MB |
| internal photos | Internal Photos | 2010-01-28 | PDF 1.5 MB |
| Internal photo | Internal Photos | 2009-02-05 | PDF 733.9 KB |
| SAR pictures | Internal Photos | 2009-02-05 | PDF 201.8 KB |
| external photos | External Photos | 2010-01-28 | PDF 109.1 KB |
| External photo | External Photos | 2009-02-05 | PDF 435 KB |
| Label | ID Label/Location Info | 2008-12-22 | PDF 54.1 KB |
| SAR test setup photos | Test Setup Photos | 2010-01-28 | PDF 288.2 KB |
| test setup photos | Test Setup Photos | 2010-01-28 | PDF 276.1 KB |
| Test Setup photo | Test Setup Photos | 2009-02-05 | PDF 129.5 KB |
| test report | Test Report | 2009-12-15 | PDF 188.9 KB |
| Test Report | Test Report | 2008-12-22 | PDF 1.1 MB |
| UTAM affidavit | Attestation Statements | 2008-12-22 | PDF 391.8 KB |
| changes letter | Cover Letter(s) | 2009-12-15 | PDF 6.6 KB |
| confidential letter | Cover Letter(s) | 2009-12-15 | PDF 27.3 KB |
| Confidentiality letter | Cover Letter(s) | 2008-12-22 | PDF 25 KB |
| POA letter | Cover Letter(s) | 2008-12-22 | PDF 24.7 KB |
| Secuirty code declaration | Cover Letter(s) | 2008-12-22 | PDF 15.3 KB |
| SAR caldata | RF Exposure Info | 2009-12-15 | PDF 1.8 MB |
| SAR plots | RF Exposure Info | 2009-12-15 | PDF 1.2 MB |
| SAR report | RF Exposure Info | 2009-12-15 | PDF 885.5 KB |
| SAR cal data | RF Exposure Info | 2008-12-22 | PDF 1.5 MB |
| SAR plots | RF Exposure Info | 2008-12-22 | PDF 686 KB |
| SAR report | RF Exposure Info | 2008-12-22 | PDF 864.3 KB |
Application Information
| Application ID | hZ3UhH7JCrAmVaUgM0eEGg== |
|---|---|
| Final Action Date | 2009-12-15 |
| Application Purpose | Class II permissive change or modification of presently authorized equipment |
| Applicant FRN | 0007403181 |
| Model | 96NKX-TGA106 |
| Frequency Range | 1921.536-1928.448 MHz |
| Equipment Class | PUE - Part 15 Unlicensed PCS portable Tx held to ear |
| Device Description | DECT Cordless Telephone Handset |
| Responsible Party | Richard Mullen, Group Manager, Richard.Mullen@us.panasonic.com |
| Technical Contact | Richard Mullen, Panasonic Corporation of North America, mullenr@us.panasonic.com |
| Test Firm | Frode Sveinsen, Nemko AS, frode.sveinsen@nemko.com |
| TCB Email | stuart.beck@nemko.com |
| TCB Scope | A3: Unlicensed Personal Communication System (PCS) devices |
| Short-Term Confidentiality | Yes |
| Short-Term Confidentiality Date | 01/28/2010 |
| Long-Term Confidentiality | No |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | Yes |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. The added model KX-TGA402 has increased head SAR of the original model KX-TGA106 from 0.013 W/kg to 0.021 W/kg. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. Body-worn configurations are limited to the accessories that were tested for this filing. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. Highest reported SAR values are head: 0.021 W/kg; body: 0.016 W/kg |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| hZ3UhH7JCrAmVaUgM0eEGg== | 2009-12-15 | Class II permissive change or modification of presently authorized equipment |
| v8MuW3zJtaVXqMYlkHyFHQ== | 2008-12-22 | Original Equipment |
Equipment Authorization
| Frequency | Output | Rules |
|---|---|---|
| 1921.536-1928.448 MHz | 0.0560000 | 15D |
Grants
TCB Grant - Application v8MuW3zJtaVXqMYlkHyFHQ==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko Canada Inc. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 12/22/2008 Application Dated: 12/22/2008 |
| Panasonic Corporation of North America |
| Two Riverfront Plaza, 9th Floor |
| Newark, NJ 07102-5490 |
| Attention: Richard Mullen , Group Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ACJ96NKX-TGA106 |
| Name of Grantee: | Panasonic Corporation of North America |
| Equipment Class: | Part 15 Unlicensed PCS portable Tx held to ear |
| Notes: | Part 15 Unlicensed PCS Portable Tx Held to Ear |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15D | 1921.536 - 1928.448 | 0.056 |
| Power listed is conducted. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. Body-worn configurations are limited to the accessories that were tested for this filing. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. Highest reported SAR values are head: 0.013 W/kg; body: 0.014 W/kg |
EAS Grant - Application v8MuW3zJtaVXqMYlkHyFHQ==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Panasonic Corporation of North America Two Riverfront Plaza, 9th Floor Newark, NJ 07102-5490 United States |
Date of Grant: 12/22/2008 Application Dated: 12/22/2008 |
| Attention: Richard Mullen , Group Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ACJ96NKX-TGA106 |
| Name of Grantee: | Panasonic Corporation of North America |
| Equipment Class: | Part 15 Unlicensed PCS portable Tx held to ear |
| Notes: | Part 15 Unlicensed PCS Portable Tx Held to Ear |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15D | 1921.536 - 1928.448 | 0.056 |
| Power listed is conducted. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. Body-worn configurations are limited to the accessories that were tested for this filing. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. Highest reported SAR values are head: 0.013 W/kg; body: 0.014 W/kg |
| Mail To: | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Nemko Canada Inc. 303 River Road Ottawa, Ontario, K1V 1H2 Canada |
Date of Grant: 12/15/2009 Application Dated: 12/14/2009 |
| Panasonic Corporation of North America |
| Two Riverfront Plaza, 9th Floor |
| Newark, NJ 07102-5490 |
| Attention: Richard Mullen , Group Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ACJ96NKX-TGA106 |
| Name of Grantee: | Panasonic Corporation of North America |
| Equipment Class: | Part 15 Unlicensed PCS portable Tx held to ear |
| Notes: | DECT Cordless Telephone Handset |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15D | 1921.536 - 1928.448 | 0.056 |
| Power listed is conducted. The added model KX-TGA402 has increased head SAR of the original model KX-TGA106 from 0.013 W/kg to 0.021 W/kg. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. Body-worn configurations are limited to the accessories that were tested for this filing. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. Highest reported SAR values are head: 0.021 W/kg; body: 0.016 W/kg |
EAS Grant - Application hZ3UhH7JCrAmVaUgM0eEGg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Panasonic Corporation of North America Two Riverfront Plaza, 9th Floor Newark, NJ 07102-5490 United States |
Date of Grant: 12/15/2009 Application Dated: 12/14/2009 |
| Attention: Richard Mullen , Group Manager |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ACJ96NKX-TGA106 |
| Name of Grantee: | Panasonic Corporation of North America |
| Equipment Class: | Part 15 Unlicensed PCS portable Tx held to ear |
| Notes: | DECT Cordless Telephone Handset |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 15D | 1921.536 - 1928.448 | 0.056 |
| Power listed is conducted. The added model KX-TGA402 has increased head SAR of the original model KX-TGA106 from 0.013 W/kg to 0.021 W/kg. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. Body-worn configurations are limited to the accessories that were tested for this filing. End-users must be provided with specific operating instructions for satisfying RF exposure compliance. Highest reported SAR values are head: 0.021 W/kg; body: 0.016 W/kg |
| Mail To: |