FCC ID AEJSH202075

ISM Base Station for health monitoring equipment

by Sensium Healthcare Ltd

Grantee Code: AEJ   Product Code: SH202075
Latest application date: 2022-04-14

FCC ID Device Details

FCC IDAEJSH202075
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeAEJ
Product CodeSH202075
Applicant BusinessSensium Healthcare Ltd 🇬🇧
Related Domains sensium.co.uk
Equipment ClassISM Base Station for health monitoring equipment
Test FirmTUV SUD Limited

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
902.6-927.4 MHzClass II permissive change or modification of presently authorized equipment2022-04-14
902-928 MHzOriginal Equipment2022-01-27

Exhibits

DocumentTypeAvailableFile
QSGUsers Manual2022-07-16PDF 1.1 MB
User GuideUsers Manual2022-07-16PDF 5.8 MB
Top Side of moduleInternal Photos2022-07-16PDF 2.8 MB
Bottom Side of moduleExternal Photos2022-07-16PDF 2.5 MB
Label 1ID Label/Location Info2022-01-27PDF 484.5 KB
Label 2ID Label/Location Info2022-01-27PDF 567.3 KB
Operating DescriptionOperational Description2022-01-27PDF 1.6 MB
Test setup photosTest Setup Photos2022-07-16PDF 798.1 KB
Base Station Test ReportTest Report2022-04-14PDF 1.2 MB
FCC 47CFR 1.1310Test Report2022-01-27PDF 240.6 KB
FCC 47CFR 15BTest Report2022-01-27PDF 719.8 KB
FCC 47CFR 15CTest Report2022-01-27PDF 928 KB
Attestation StatementAttestation Statements2022-01-27PDF 408.9 KB
C2PC Cover LetterCover Letter(s)2022-04-14PDF 162.7 KB
Technical Justification for Home and Hospital BridgesCover Letter(s)2022-04-14PDF 616.8 KB
Agent LetterCover Letter(s)2022-01-27PDF 373.6 KB
Confidentiality LetterCover Letter(s)2022-01-27PDF 302.8 KB
Module Approval FormCover Letter(s)2022-01-27PDF 154.1 KB
RF Exposure InfoRF Exposure Info2022-01-27PDF 182.3 KB
Block Diagram Metadata onlyBlock DiagramPDF 59.5 KB
Schematics Metadata onlySchematicsPDF 1.3 MB
Parts List Metadata onlyParts List/Tune Up InfoPDF 120.3 KB

Application Information

Application IDhjqkt5B1Eitm0pu3w3ysIQ==
Final Action Date2022-04-14
Application PurposeClass II permissive change or modification of presently authorized equipment
Applicant FRN0026178566
ModelSH202075
Frequency Range902.6-927.4 MHz
Equipment ClassDXX - Part 15 Low Power Communication Device Transmitter
Device DescriptionISM Base Station for health monitoring equipment
Responsible PartyChris Nunn, chris.nunn@sensium.co.uk , +441235438950
Test FirmNathan Emery, TUV SUD Limited, Nathan.Emery@tuvsud.com , 44 7831225502
TCB Emailrick.hooper@tuvsud.com
TCB ScopeA1: Low Power Transmitters below 1 GHz (except Spread Spectrum), Unintentional Radiators, EAS (Part 11) & Consumer ISM devices
Short-Term ConfidentialityNo
Long-Term ConfidentialityNo
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsC2PC as described in this filing to add hosts "SH202220 - US Home Bridge" and "SH202220 - US Hospital Bridge" Limited Modular Approval. Output power listed is conducted. This grant is valid only when installed in the Grantee's hosts. The antenna used for this transmitter as shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter RF exposure procedures. Separate approval is required for all other operating configurations, including portable configurations with respect to §2.1093.

Applications

Application IDDatePurpose
hjqkt5B1Eitm0pu3w3ysIQ==2022-04-14Class II permissive change or modification of presently authorized equipment
j3ywsIlRpUP4jsks9R6j4w==2022-01-27Original Equipment

Equipment Authorization

FrequencyOutputEmissionRules
902-928 MHz0.004000015C
902-928 MHz0.0040000F3D15C

Grants

TCB Grant - Application j3ywsIlRpUP4jsks9R6j4w==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  TUV SUD BABT UNLIMITED
Octagon House, Concorde Way Segensworth North
Fareham, PO15 5RL
United Kingdom
Date of Grant: 01/27/2022

Application Dated: 01/21/2022
Sensium Healthcare Ltd
Building 3
115 Milton Park
Abingdon, OX14 4SA
United Kingdom
 
Attention: Chris Nunn

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AEJSH202075
Name of Grantee:  Sensium Healthcare Ltd
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: ISM Base Station for health monitoring equipment
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.0  -  928.0 0.004   F3D

Limited Modular Approval. Output power listed is conducted. This grant is valid only when installed in the Grantee's hosts. The antenna used for this transmitter as shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multitransmitter RF exposure procedures. Separate approval is required for all other operating configurations, including portable configurations with respect to §2.1093.

EAS Grant - Application j3ywsIlRpUP4jsks9R6j4w==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensium Healthcare Ltd
Building 3 115 Milton Park
Abingdon, OX14 4SA
United Kingdom
  Date of Grant: 01/27/2022

Application Dated: 01/21/2022
 
Attention: Chris Nunn

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AEJSH202075
Name of Grantee:  Sensium Healthcare Ltd
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: ISM Base Station for health monitoring equipment
Modular Type: Limited Single Modular
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.0  -  928.0 0.004   F3D

Limited Modular Approval. Output power listed is conducted. This grant is valid only when installed in the Grantee's hosts. The antenna used for this transmitter as shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multitransmitter RF exposure procedures. Separate approval is required for all other operating configurations, including portable configurations with respect to §2.1093.



TCB Grant - Application hjqkt5B1Eitm0pu3w3ysIQ==

Mail To:
TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  TUV SUD BABT UNLIMITED
Octagon House, Concorde Way Segensworth North
Fareham, PO15 5RL
United Kingdom
Date of Grant: 04/14/2022

Application Dated: 04/14/2022
Sensium Healthcare Ltd
Building 3
115 Milton Park
Abingdon, OX14 4SA
United Kingdom
 
Attention: Chris Nunn

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AEJSH202075
Name of Grantee:  Sensium Healthcare Ltd
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: ISM Base Station for health monitoring equipment
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.0  -  928.0 0.004  

C2PC as described in this filing to add hosts "SH202220 - US Home Bridge" and "SH202220 - US Hospital Bridge"

Limited Modular Approval. Output power listed is conducted. This grant is valid only when installed in the Grantee's hosts. The antenna used for this transmitter as shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter RF exposure procedures. Separate approval is required for all other operating configurations, including portable configurations with respect to §2.1093.


EAS Grant - Application hjqkt5B1Eitm0pu3w3ysIQ==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sensium Healthcare Ltd
Building 3 115 Milton Park
Abingdon, OX14 4SA
United Kingdom
  Date of Grant: 04/14/2022

Application Dated: 04/14/2022
 
Attention: Chris Nunn

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AEJSH202075
Name of Grantee:  Sensium Healthcare Ltd
Equipment Class: Part 15 Low Power Communication Device Transmitter
Notes: ISM Base Station for health monitoring equipment
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
15C 902.0  -  928.0 0.004  

C2PC as described in this filing to add hosts "SH202220 - US Home Bridge" and "SH202220 - US Hospital Bridge"

Limited Modular Approval. Output power listed is conducted. This grant is valid only when installed in the Grantee's hosts. The antenna used for this transmitter as shown in this filing must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter RF exposure procedures. Separate approval is required for all other operating configurations, including portable configurations with respect to §2.1093.



Mail To: