FCC ID AEZSCP-47H

Dual-Band Analog/PCS Phone (AMPS/CDMA)

by Sanyo Electric Co Ltd

Grantee Code: AEZ   Product Code: SCP47H
Latest application date: 2001-06-22

FCC ID Device Details

FCC IDAEZSCP-47H
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeAEZ
Product CodeSCP47H
Applicant BusinessSanyo Electric Co Ltd 🇺🇸
Related Domains sanyo.com pctestlab.com
Equipment ClassDual-Band Analog/PCS Phone (AMPS/CDMA)
Test FirmPCTEST Engineering Laboratory, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
824.04-848.97 MHzOriginal Equipment2001-06-22

Exhibits

DocumentTypeAvailableFile
Users ManualUsers Manual2001-06-22PDF 1.9 MB
Internal PhotosInternal Photos2001-06-22PDF 2.4 MB
External PhotosExternal Photos2001-06-22PDF 966.8 KB
FCC ID Label and LocationID Label/Location Info2001-06-22PDF 112 KB
Revised FCC ID and Location per CRN 19712ID Label/Location Info2001-06-22PDF 62.4 KB
Operational DescriptionOperational Description2001-06-22PDF 55.3 KB
SAR Test Setup PhotosRF Exposure Info2001-06-22PDF 1.1 MB
Test Setup PhotosTest Setup Photos2001-06-22PDF 744.8 KB
Test PlotsTest Report2001-06-22PDF 1 MB
Test ReportTest Report2001-06-22PDF 295.3 KB
Attestation StatementsAttestation Statements2001-06-22PDF 132.9 KB
Cover LetterCover Letter(s)2001-06-22PDF 26.9 KB
Cover Letter per CRN 19701Cover Letter(s)2001-06-22PDF 63.5 KB
Cover Letter per CRN 19712Cover Letter(s)2001-06-22PDF 63.5 KB
Dipole Validation PlotsRF Exposure Info2001-06-22PDF 324.3 KB
Parts List and Tune Up ProcedureParts List/Tune Up Info2001-06-22PDF 102.6 KB
Probe Calibration DataRF Exposure Info2001-06-22PDF 222.7 KB
SAR ReportRF Exposure Info2001-06-22PDF 530.3 KB
SAR Test DataRF Exposure Info2001-06-22PDF 1.5 MB
Block Diagram Metadata onlyBlock DiagramPDF 107.5 KB
Schematics Metadata onlySchematicsPDF 552.9 KB
Revised Tune Up Procedure per CRN 19701 Metadata onlyParts List/Tune Up InfoPDF 159 KB

Application Information

Application IDM2BpT2HESivmVX/QlO5aAw==
Final Action Date2001-06-22
Application PurposeOriginal Equipment
Applicant FRN0005810585
ModelSCP-47H
Frequency Range824.04-848.97 MHz
Equipment ClassPCE - PCS Licensed Transmitter held to ear
Device DescriptionDual-Band Analog/PCS Phone (AMPS/CDMA)
Responsible PartyHideaki Mukaida, Hideaki.Mukaida@sanyo.com , 818-998-7322
AgentRandy Randy Randy, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com , 410-290-6652
Technical ContactRandy Ortanez, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com , 410-290-6652
Non-Technical ContactRandy Ortanez, PCTEST Engineering Laboratory, Inc., randy@pctestlab.com , 410-290-6652
Test FirmRandy Ortanez, PCTEST Engineering Laboratory, Inc., ro@pctestlab.com , 410-290-6652
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput is ERP for Part 22 and EIRP for Part 24. For AMPS mode operations, units produced must not exceed 400 mW conducted output, as tested for this filing, for satisfying RF exposure compliance. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Part 22 (AMPS) - Head: 1.34 W/kg; Body-worn: 1.27 W/kg Part 24 (CDMA) - Head: 1.39 W/kg; Body-worn: 1.15 W/kg

Applications

Application IDDatePurpose
M2BpT2HESivmVX/QlO5aAw==2001-06-22Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
824.04-848.97 MHz0.62.5ppm40K0F8W22HBC
824.04-848.97 MHz0.62.5ppm40K0F1D22HBC
1851.25-1908.75 MHz0.332.5ppm1M25F9W24E

Grants

TCB Grant - Application M2BpT2HESivmVX/QlO5aAw==

This application does not exist.

EAS Grant - Application M2BpT2HESivmVX/QlO5aAw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Sanyo Electric Co Ltd
c/o Sanyo Fisher Company 21605 Plummer Street
Chatsworth, CA 91311
United States
  Date of Grant: 06/22/2001

Application Dated: 06/07/2001
 
Attention: Hideaki Mukaida

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AEZSCP-47H
Name of Grantee:  Sanyo Electric Co Ltd
Equipment Class: PCS Licensed Transmitter held to ear
Notes: Dual-Band Analog/PCS Phone (AMPS/CDMA)
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
BC 22H 824.04  -  848.97 0.6 2.5  PM 40K0F8W
BC 22H 824.04  -  848.97 0.6 2.5  PM 40K0F1D
24E 1851.25  -  1908.75 0.33 2.5  PM 1M25F9W

Output is ERP for Part 22 and EIRP for Part 24. For AMPS mode operations, units produced must not exceed 400 mW conducted output, as tested for this filing, for satisfying RF exposure compliance. SAR compliance for body-worn operating configurations is limited to the specific configuration tested for this filing. Body-worn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 1.5 cm separation between the device, including its antenna whether extended or retracted, and the user's body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels are: Part 22 (AMPS) - Head: 1.34 W/kg; Body-worn: 1.27 W/kg Part 24 (CDMA) - Head: 1.39 W/kg; Body-worn: 1.15 W/kg


BC: The output power is continuously variable from the value listed in this entry to 5%-10% of the value listed.

Mail To:
Randy Ortanez, President
PCTEST Engineering Laboratory, Inc.
6660-B Dobbin Road
Columbia, MD 21045