FCC ID AFJ439111

UHF TRANSCEIVER

by ICOM Incorporated

Grantee Code: AFJ   Product Code: 439111
Latest application date: 2023-05-19

FCC ID Device Details

FCC IDAFJ439111
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeAFJ
Product Code439111
Applicant BusinessICOM Incorporated 🇯🇵
Related Domains icom.co.jp
Equipment ClassUHF TRANSCEIVER
Test FirmUltraTech Engineering Labs Inc

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
450-470 MHzOriginal Equipment2023-05-19

Exhibits

DocumentTypeAvailableFile
User manualUsers Manual2023-08-25PDF 401.6 KB
Antenna infoUsers Manual2023-05-19PDF 132 KB
Internal PhotosInternal Photos2023-08-25PDF 255.2 KB
External photosExternal Photos2023-08-25PDF 217.9 KB
Label and LocationID Label/Location Info2023-05-19PDF 126.8 KB
Test Setup photosTest Setup Photos2023-05-19PDF 238.3 KB
RF Test reportTest Report2023-05-19PDF 1.2 MB
2.911-d-5-i-ii AttestationAttestation Statements2023-05-19PDF 25.3 KB
25KHz Attestation letterAttestation Statements2023-05-19PDF 16.7 KB
90.203 letterAttestation Statements2023-05-19PDF 21.1 KB
Agent Authority letterAttestation Statements2023-05-19PDF 28.8 KB
EF JustificationAttestation Statements2023-05-19PDF 45.4 KB
Manufacturers letterAttestation Statements2023-05-19PDF 17.8 KB
US Agent designationAttestation Statements2023-05-19PDF 89.1 KB
Unintentional SDoCAttestation Statements2023-05-19PDF 60.6 KB
Confidentiality requestCover Letter(s)2023-05-19PDF 28.4 KB
Cover LetterCover Letter(s)2023-05-19PDF 137.7 KB
SAR reportRF Exposure Info2023-05-19PDF 1.2 MB
SAR report Appendix 1RF Exposure Info2023-05-19PDF 944.2 KB
SAR report Appendix 2RF Exposure Info2023-05-19PDF 931.3 KB
SAR report Appendix 3RF Exposure Info2023-05-19PDF 328.8 KB
Block Diagram Metadata onlyBlock DiagramPDF 36.2 KB
Schematics Metadata onlySchematicsPDF 150.3 KB
Operational Description Metadata onlyOperational DescriptionPDF 56.8 KB
Parts List Metadata onlyParts List/Tune Up InfoPDF 210.2 KB
Tune up Info Metadata onlyParts List/Tune Up InfoPDF 107.4 KB

Application Information

Application IDb/yDs75+kHm/OHhbZTCcsA==
Final Action Date2023-05-19
Application PurposeOriginal Equipment
Applicant FRN0005855366
Model439111
Frequency Range450-470 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionUHF TRANSCEIVER
Responsible PartyAtsushi Tomiyama, General Manager, world_support@icom.co.jp , +81667938424
AgentSanthosh Santhosh Santhosh, Ultratech Engineering Labs Inc., santhosh@ultratech-labs.com , 9058291570
Test FirmTri Luu, UltraTech Engineering Labs Inc, tri@ultratech-labs.com , 905-829-1570
TCB Emailvic@ultratech-labs.com
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityYes
Short-Term Confidentiality Date08/25/2023
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput Power listed is rated. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for body worn operation has been tested and meets the FCC RF exposure guidelines when used with the ICOM listed accessories designated for this product as shown in the filing. End users must be informed of the body worn requirements for satisfying RF exposure compliance. This device must transmit with a source-based time-averaging duty factor not exceeding 50%. This device must be restricted to work related operations in an occupational/controlled RF exposure environment. SAR was evaluated for body worn and held-to-face operating modes and found not to exceed the SAR 1g average limit of 8 W/Kg for occupational/controlled environments. Maximum SAR values reported are: Head 1.487 W/Kg and Body 2.396 W/Kg.

Applications

Application IDDatePurpose
b/yDs75+kHm/OHhbZTCcsA==2023-05-19Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRulesGrant Notes
450-470 MHz2500Hz11K0F3E22, 74, 80, 9EF
450-470 MHz1500Hz11K0F3E22, 74, 80, 9EF

Grants

TCB Grant - Application b/yDs75+kHm/OHhbZTCcsA==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Ultratech Engineering Labs Inc.
3000 Bristol Circle
Oakville Ontario, L6H 6G4
Canada
Date of Grant: 05/19/2023

Application Dated: 05/18/2023
ICOM Incorporated
1-1-32 Kamiminami
Hirano-ku
Osaka, 547-0003
Japan
 
Attention: Atsushi Tomiyama , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AFJ439111
Name of Grantee:  ICOM Incorporated
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: UHF TRANSCEIVER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EF 22, 74, 80, 90 450.0  -  470.0 2.0 500.0  Hz 11K0F3E
EF 22, 74, 80, 90 450.0  -  470.0 1.0 500.0  Hz 11K0F3E

Output Power listed is rated. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for body worn operation has been tested and meets the FCC RF exposure guidelines when used with the ICOM listed accessories designated for this product as shown in the filing. End users must be informed of the body worn requirements for satisfying RF exposure compliance. This device must transmit with a source-based time-averaging duty factor not exceeding 50%. This device must be restricted to work related operations in an occupational/controlled RF exposure environment. SAR was evaluated for body worn and held-to-face operating modes and found not to exceed the SAR 1g average limit of 8 W/Kg for occupational/controlled environments. Maximum SAR values reported are: Head 1.487 W/Kg and Body 2.396 W/Kg.

EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

EAS Grant - Application b/yDs75+kHm/OHhbZTCcsA==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

ICOM Incorporated
1-1-32 Kamiminami Hirano-ku
Osaka, 547-0003
Japan
  Date of Grant: 05/19/2023

Application Dated: 05/18/2023
 
Attention: Atsushi Tomiyama , General Manager

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AFJ439111
Name of Grantee:  ICOM Incorporated
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: UHF TRANSCEIVER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
EF 22, 74, 80, 90 450.0  -  470.0 2.0 500.0  Hz 11K0F3E
EF 22, 74, 80, 90 450.0  -  470.0 1.0 500.0  Hz 11K0F3E

Output Power listed is rated. This device must not be collocated or operating in conjunction with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures identified in this filing. SAR for body worn operation has been tested and meets the FCC RF exposure guidelines when used with the ICOM listed accessories designated for this product as shown in the filing. End users must be informed of the body worn requirements for satisfying RF exposure compliance. This device must transmit with a source-based time-averaging duty factor not exceeding 50%. This device must be restricted to work related operations in an occupational/controlled RF exposure environment. SAR was evaluated for body worn and held-to-face operating modes and found not to exceed the SAR 1g average limit of 8 W/Kg for occupational/controlled environments. Maximum SAR values reported are: Head 1.487 W/Kg and Body 2.396 W/Kg.


EF: This device may contain functions that are not operational in U.S Territories except as noted in the filing. This grant has extended frequencies as noted in the filing and Section 2.927(b) applies to this authorization.

Mail To: