FCC ID AIERIT19-150

VHF-FM PROTABLE TRANSCEIVER

by Ritron Inc

Grantee Code: AIE   Product Code: RIT19150
Latest application date: 2005-01-20

FCC ID Device Details

FCC IDAIERIT19-150
Mirrorsfcc.id | gov | fccid.ai
Grantee CodeAIE
Product CodeRIT19150
Applicant BusinessRitron Inc 🇺🇸
Related Domains ritron.com
Equipment ClassVHF-FM PROTABLE TRANSCEIVER
Test FirmRITRON, Inc.

Operating Frequencies

Frequency RangeApplication PurposeFinal Action Date
136-174 MHzOriginal Equipment2005-01-20

Exhibits

DocumentTypeAvailableFile
USERS MANUALUsers Manual2005-01-20PDF 538.7 KB
INTERNAL PHOTOS 1Internal Photos2005-01-20PDF 3.2 MB
INTERNAL PHOTOS 2Internal Photos2005-01-20PDF 2 MB
EXTERNAL PHOTOSExternal Photos2005-01-20PDF 2.7 MB
ID LABELID Label/Location Info2005-01-20PDF 1.5 MB
OPERATIONAL DESCRIPTIONOperational Description2005-01-20PDF 318.5 KB
TEST REPORTTest Report2005-01-20PDF 194.8 KB
95J authorizationCover Letter(s)2005-01-20PDF 13.3 KB
CONFIDENTIALITY LETTERCover Letter(s)2005-01-20PDF 64.8 KB
TUNE UPParts List/Tune Up Info2005-01-20PDF 125.5 KB
BLOCK DIAGRAM Metadata onlyBlock DiagramPDF 157.2 KB
SCHEMATICS Metadata onlySchematicsPDF 2.5 MB
PARTS LIST Metadata onlyParts List/Tune Up InfoPDF 58.1 KB

Application Information

Application IDE3nhj612Bo0icJgWUClBCw==
Final Action Date2005-01-20
Application PurposeOriginal Equipment
Applicant FRN0004334876
ModelRIT19-150
Frequency Range136-174 MHz
Equipment ClassTNF - Licensed Non-Broadcast Transmitter Held to Face
Device DescriptionVHF-FM PROTABLE TRANSCEIVER
Responsible PartySam L. Dulaney, Chief Engineer, sdulaney@ritron.com , 317 846-1201
Test FirmSam Dulaney, RITRON, Inc., sdulaney@ritron.com , 317-846-1201
TCB EmailTEI@TIMCOENGR.COM
TCB ScopeB2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz)
Short-Term ConfidentialityNo
Long-Term ConfidentialityYes
Grant DeferralNo
Modular EquipmentDoes not apply
Composite DeviceNo
Composite PartNo
Cognitive RadioNo
Authorization WaiverNo
Authorization Waiver ApprovedNo
Section 5301 CertificationYes
Related OET Knowledge DataBase InquiryNo
Grant CommentsOutput is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with RF exposure limits and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information.

Applications

Application IDDatePurpose
E3nhj612Bo0icJgWUClBCw==2005-01-20Original Equipment

Equipment Authorization

FrequencyOutputToleranceEmissionRules
136-174 MHz15ppm11K0F3E74, 90, 95J
136-174 MHz15ppm16K0F3E74, 9
136-174 MHz55ppm11K0F3E74, 90, 95J
136-174 MHz55ppm16K0F3E74, 9

Grants

TCB Grant - Application E3nhj612Bo0icJgWUClBCw==

TCB GRANT OF EQUIPMENT
AUTHORIZATION
TCB
Certification
Issued Under the Authority of the
Federal Communications Commission
By:

  Timco Engineering, Inc.
849 NW State Road 45
Newberry, FL 32669
Date of Grant: 01/20/2005

Application Dated: 01/20/2005
Ritron Inc
505 West Carmel Drive
Carmel, IN 46032
 
Attention: Sam Dulaney , Chief Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AIERIT19-150
Name of Grantee:  Ritron Inc
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: VHF-FM PROTABLE TRANSCEIVER
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
74, 90, 95J 136.0  -  174.0 1.0 5.0  PM 11K0F3E
74, 90 136.0  -  174.0 1.0 5.0  PM 16K0F3E
74, 90, 95J 136.0  -  174.0 5.0 5.0  PM 11K0F3E
74, 90 136.0  -  174.0 5.0 5.0  PM 16K0F3E

Output is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with RF exposure limits and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information.

EAS Grant - Application E3nhj612Bo0icJgWUClBCw==

COPY FEDERAL COMMUNICATIONS
COMMISSION
WASHINGTON, D.C. 20554

GRANT OF EQUIPMENT
AUTHORIZATION
COPY
Certification

Ritron Inc
505 West Carmel Drive
Carmel, IN 46032
United States
  Date of Grant: 01/20/2005

Application Dated: 01/20/2005
 
Attention: Sam Dulaney , Chief Engineer

NOT TRANSFERABLE
EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below.
 
FCC IDENTIFIER:  AIERIT19-150
Name of Grantee:  Ritron Inc
Equipment Class: Licensed Non-Broadcast Transmitter Held to Face
Notes: VHF-FM PROTABLE TRANSCEIVER
Modular Type: Does not apply
Grant Notes  FCC Rule Parts Frequency
Range (MHZ)
Output
Watts
Frequency
Tolerance
Emission
Designator
74, 90, 95J 136.0  -  174.0 1.0 5.0  PM 11K0F3E
74, 90 136.0  -  174.0 1.0 5.0  PM 16K0F3E
74, 90, 95J 136.0  -  174.0 5.0 5.0  PM 11K0F3E
74, 90 136.0  -  174.0 5.0 5.0  PM 16K0F3E

Output is conducted. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with RF exposure limits and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information.



Mail To: