FCC ID AIERIT48-152M
VHF-FM MURS HANDHELD TRANSCEIVER
by Ritron Inc
Grantee Code: AIE Product Code: RIT48152M
Latest application date: 2020-04-23
FCC ID Device Details
| FCC ID | AIERIT48-152M |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | AIE |
| Product Code | RIT48152M |
| Applicant Business | Ritron Inc 🇺🇸 |
| Related Domains | |
| Equipment Class | VHF-FM MURS HANDHELD TRANSCEIVER |
| Test Firm | Timco Engineering, Inc. |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 151.82 MHz | Original Equipment | 2020-04-23 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| User Manual MURS | Users Manual | 2020-04-23 | PDF 1.1 MB |
| Internal Photos | Internal Photos | 2020-04-23 | PDF 143.2 KB |
| External Photos | External Photos | 2020-04-23 | PDF 250 KB |
| Label Info | ID Label/Location Info | 2020-04-23 | PDF 477.7 KB |
| Label Location | ID Label/Location Info | 2020-04-23 | PDF 186.7 KB |
| Test Setup Photos | Test Setup Photos | 2020-04-23 | PDF 263.1 KB |
| Test Setup Photos SAR | RF Exposure Info | 2020-04-23 | PDF 343.5 KB |
| SAR Test Report | RF Exposure Info | 2020-04-23 | PDF 1.8 MB |
| Test Report MURS | Test Report | 2020-04-23 | PDF 1.9 MB |
| Confidentiality Letter | Cover Letter(s) | 2020-04-23 | PDF 91.6 KB |
| POA Letter | Cover Letter(s) | 2020-04-23 | PDF 304.3 KB |
| SAR Calibration Certificate | RF Exposure Info | 2020-04-23 | PDF 3.8 MB |
| SAR Plots | RF Exposure Info | 2020-04-23 | PDF 1.9 MB |
| Block Diagram Metadata only | Block Diagram | PDF 71.6 KB | |
| Schematics Metadata only | Schematics | PDF 158.3 KB | |
| Operational Description Metadata only | Operational Description | PDF 57.2 KB | |
| Parts List Metadata only | Parts List/Tune Up Info | PDF 65.4 KB | |
| Tune Up Procedure Metadata only | Parts List/Tune Up Info | PDF 69 KB |
Application Information
| Application ID | W/xpPC23HbYhgOHKR7Eftg== |
|---|---|
| Final Action Date | 2020-04-23 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0004334876 |
| Model | RIT48-152M |
| Frequency Range | 151.82 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | VHF-FM MURS HANDHELD TRANSCEIVER |
| Responsible Party | Sam L. Dulaney, Chief Engineer, sdulaney@ritron.com |
| Test Firm | Bruno Clavier, Timco Engineering, Inc., bruno@timcoengr.com |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. Maximum conducted rated output power is 2.0W according to 95.2767. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip, holster, and accessories tested for this filing and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 2.0 cm separation between the device, including its antenna, and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels for Head and Body-Worn accessories are 1.15 W/kg and 0.34 W/kg respectively for a 50% Duty Cycle. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| W/xpPC23HbYhgOHKR7Eftg== | 2020-04-23 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application W/xpPC23HbYhgOHKR7Eftg==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 04/23/2020 Application Dated: 04/23/2020 |
| Ritron Inc |
| 505 West Carmel Drive |
| Carmel, IN 46032 |
| Attention: Sam Dulaney , Chief Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | AIERIT48-152M |
| Name of Grantee: | Ritron Inc |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | VHF-FM MURS HANDHELD TRANSCEIVER |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95J | 151.82 - 151.82 | 2.0 | 1800.0 Hz | 11K0F3E | |
| 95J | 151.88 - 151.88 | 2.0 | 1800.0 Hz | 11K0F3E | |
| 95J | 151.94 - 151.94 | 2.0 | 1800.0 Hz | 11K0F3E | |
| 95J | 154.57 - 154.57 | 2.0 | 1800.0 Hz | 16K0F3E | |
| 95J | 154.6 - 154.6 | 2.0 | 1800.0 Hz | 16K0F3E |
| Power listed is conducted. Maximum conducted rated output power is 2.0W according to 95.2767. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip, holster, and accessories tested for this filing and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 2.0 cm separation between the device, including its antenna, and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels for Head and Body-Worn accessories are 1.15 W/kg and 0.34 W/kg respectively for a 50% Duty Cycle. |
EAS Grant - Application W/xpPC23HbYhgOHKR7Eftg==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Ritron Inc 505 West Carmel Drive Carmel, IN 46032 United States |
Date of Grant: 04/23/2020 Application Dated: 04/23/2020 |
| Attention: Sam Dulaney , Chief Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | AIERIT48-152M |
| Name of Grantee: | Ritron Inc |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | VHF-FM MURS HANDHELD TRANSCEIVER |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| 95J | 151.82 - 151.82 | 2.0 | 1800.0 Hz | 11K0F3E | |
| 95J | 151.88 - 151.88 | 2.0 | 1800.0 Hz | 11K0F3E | |
| 95J | 151.94 - 151.94 | 2.0 | 1800.0 Hz | 11K0F3E | |
| 95J | 154.57 - 154.57 | 2.0 | 1800.0 Hz | 16K0F3E | |
| 95J | 154.6 - 154.6 | 2.0 | 1800.0 Hz | 16K0F3E |
| Power listed is conducted. Maximum conducted rated output power is 2.0W according to 95.2767. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with the Occupational/Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements. SAR compliance for body-worn operating configurations is limited to the specific belt-clip, holster, and accessories tested for this filing and to belt-clips, holsters, or similar accessories that have no metallic component in the assembly and which provide at least 2.0 cm separation between the device, including its antenna, and the users body. End-users must be informed of the body-worn operating requirements for satisfying RF exposure compliance. The highest reported SAR levels for Head and Body-Worn accessories are 1.15 W/kg and 0.34 W/kg respectively for a 50% Duty Cycle. |
| Mail To: |