FCC ID ALH34713130
UHF FM HANDHELD TRANSCEIVERS
by Kenwood USA Corporation
Grantee Code: ALH Product Code: 34713130
Latest application date: 2004-11-12
FCC ID Device Details
| FCC ID | ALH34713130 |
|---|---|
| Mirrors | fcc.id | gov | fccid.ai |
| Grantee Code | ALH |
| Product Code | 34713130 |
| Applicant Business | Kenwood USA Corporation 🇺🇸 |
| Related Domains | |
| Equipment Class | UHF FM HANDHELD TRANSCEIVERS |
| Test Firm | Compliance Testing, LLC |
Operating Frequencies
| Frequency Range | Application Purpose | Final Action Date |
|---|---|---|
| 400-430 MHz | Original Equipment | 2004-11-12 |
Exhibits
| Document | Type | Available | File |
|---|---|---|---|
| USERS MANUAL | Users Manual | 2004-11-12 | PDF 302.5 KB |
| INTERNAL PHOTOS | Internal Photos | 2004-11-12 | PDF 31 KB |
| EXTERNAL PHOTOS | External Photos | 2004-11-12 | PDF 78.5 KB |
| ID LABEL AND LOCATION | ID Label/Location Info | 2004-11-12 | PDF 172.2 KB |
| TEST REPORT | Test Report | 2004-11-12 | PDF 890.3 KB |
| CONFIDENTIALITY LETTER | Cover Letter(s) | 2004-11-12 | PDF 42.3 KB |
| SAR REPORT 1 | RF Exposure Info | 2004-11-12 | PDF 2.3 MB |
| SAR REPORT 2 | RF Exposure Info | 2004-11-12 | PDF 1.1 MB |
| SAR REPORT 3 | RF Exposure Info | 2004-11-12 | PDF 2.1 MB |
| BLOCK DIAGRAM Metadata only | Block Diagram | PDF 57.9 KB | |
| SCHEMATICS Metadata only | Schematics | PDF 309.1 KB | |
| OPERATIONAL DESCRIPTION Metadata only | Operational Description | PDF 15.6 KB | |
| ACTIVE DEVICE Metadata only | Parts List/Tune Up Info | PDF 6.2 KB | |
| PARTS LIST Metadata only | Parts List/Tune Up Info | PDF 5 KB | |
| TUNE UP Metadata only | Parts List/Tune Up Info | PDF 12.9 KB |
Application Information
| Application ID | zartY4k97NxedZVXul/DPw== |
|---|---|
| Final Action Date | 2004-11-12 |
| Application Purpose | Original Equipment |
| Applicant FRN | 0004356960 |
| Model | 34713130 |
| Frequency Range | 400-430 MHz |
| Equipment Class | TNF - Licensed Non-Broadcast Transmitter Held to Face |
| Device Description | UHF FM HANDHELD TRANSCEIVERS |
| Responsible Party | Angelina Seay, Regulatory Support Engineer, aseay@us.jvckenwood.com |
| Test Firm | Michael Schafer, Compliance Testing, LLC, michaels@compliancetesting.com |
| TCB Email | TEI@TIMCOENGR.COM |
| TCB Scope | B2: General Mobile Radio And Broadcast Services equipment in the following 47 CFR Parts 22 (non-cellular) 73, 74, 90, 95, 97, & 101 (all below 3 GHz) |
| Short-Term Confidentiality | No |
| Long-Term Confidentiality | Yes |
| Grant Deferral | No |
| Modular Equipment | Does not apply |
| Composite Device | No |
| Composite Part | No |
| Cognitive Radio | No |
| Authorization Waiver | No |
| Authorization Waiver Approved | No |
| Section 5301 Certification | Yes |
| Related OET Knowledge DataBase Inquiry | No |
| Grant Comments | Power listed is conducted. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Hand held and body-worn SAR compliance is limited to the specific antennas / belt-clips / holsters / accessories tested for this device. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 3.63 W/kg; Body-worn: 6.80 W/kg, both values represent a 50% duty factor. |
Applications
| Application ID | Date | Purpose |
|---|---|---|
| zartY4k97NxedZVXul/DPw== | 2004-11-12 | Original Equipment |
Equipment Authorization
Grants
TCB Grant - Application zartY4k97NxedZVXul/DPw==
| TCB | GRANT OF EQUIPMENT AUTHORIZATION |
TCB |
| Certification | ||
| Issued Under the Authority of the | ||
| Federal Communications Commission | ||
| By: |
|
Timco Engineering, Inc. 849 NW State Road 45 Newberry, FL 32669 |
Date of Grant: 11/12/2004 Application Dated: 11/12/2004 |
| Kenwood USA Corporation |
| 5000 Research Ct |
| Suite 700 |
| Suwanee, GA 30024 |
| Attention: Angelina Seay , Regulatory Support Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ALH34713130 |
| Name of Grantee: | Kenwood USA Corporation |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | UHF FM HANDHELD TRANSCEIVERS |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BG | 22, 74, 90, 90.210 | 400.0 - 430.0 | 1.0 | 2.5 PM | 16K0F3E |
| BG | 22, 74, 90, 90.210 | 400.0 - 430.0 | 4.0 | 2.5 PM | 16K0F3E |
| BG | 22, 74, 90, 90.210 | 400.0 - 430.0 | 1.0 | 2.5 PM | 11K0F3E |
| BG | 22, 74, 90, 90.210 | 400.0 - 430.0 | 4.0 | 2.5 PM | 11K0F3E |
| Power listed is conducted. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Hand held and body-worn SAR compliance is limited to the specific antennas / belt-clips / holsters / accessories tested for this device. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 3.63 W/kg; Body-worn: 6.80 W/kg, both values represent a 50% duty factor. |
| BG: | The output power is continuously variable from the value listed in this entry to 25%-30% of the value listed. |
EAS Grant - Application zartY4k97NxedZVXul/DPw==
| COPY |
FEDERAL COMMUNICATIONS COMMISSION WASHINGTON, D.C. 20554 GRANT OF EQUIPMENT AUTHORIZATION |
COPY |
| Certification |
|
Kenwood USA Corporation 5000 Research Ct Suite 700 Suwanee, GA 30024 United States |
Date of Grant: 11/12/2004 Application Dated: 11/12/2004 |
| Attention: Angelina Seay , Regulatory Support Engineer |
| NOT TRANSFERABLE |
| EQUIPMENT AUTHORIZATION is hereby issued to the named GRANTEE, and is VALID ONLY for the equipment identified hereon for use under the Commission's Rules and Regulations listed below. |
| FCC IDENTIFIER: | ALH34713130 |
| Name of Grantee: | Kenwood USA Corporation |
| Equipment Class: | Licensed Non-Broadcast Transmitter Held to Face |
| Notes: | UHF FM HANDHELD TRANSCEIVERS |
| Modular Type: | Does not apply |
| Grant Notes | FCC Rule Parts | Frequency Range (MHZ) | Output Watts | Frequency Tolerance | Emission Designator |
| BG | 22, 74, 90, 90.210 | 400.0 - 430.0 | 1.0 | 2.5 PM | 16K0F3E |
| BG | 22, 74, 90, 90.210 | 400.0 - 430.0 | 4.0 | 2.5 PM | 16K0F3E |
| BG | 22, 74, 90, 90.210 | 400.0 - 430.0 | 1.0 | 2.5 PM | 11K0F3E |
| BG | 22, 74, 90, 90.210 | 400.0 - 430.0 | 4.0 | 2.5 PM | 11K0F3E |
| Power listed is conducted. This transmitter has been tested for SAR compliance in Push-to-Talk and body-worn operating configurations. Hand held and body-worn SAR compliance is limited to the specific antennas / belt-clips / holsters / accessories tested for this device. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment and must operate with a duty factor not exceeding 50%. All qualified end-users of this device must have the knowledge to control their exposure conditions and/or duration to comply with Occupational /Controlled SAR limit and requirements. A label, as described in this filing, must be displayed on the device to direct users to specific training information for meeting Occupational Exposure Requirements and users must be provided with the training information. The highest reported SAR values are - Head: 3.63 W/kg; Body-worn: 6.80 W/kg, both values represent a 50% duty factor. |
| BG: | The output power is continuously variable from the value listed in this entry to 25%-30% of the value listed. |
| Mail To: |